Care should be taken when cleaning in the area of the evaporator - it is recommended that protective 
gloves should be worn as the evaporator fins can have sharp edges. 

9.6.1.The external parts of cleaning :( daily/weekly) 

 

Neutral detergents, soap and water will be used weekly for cleaning the external parts. 

 

Wash it with clean water and dry it with a soft cloth. 

 

Do not use abrasive products and solvent that may cause any scrap on the surface of the cabinet. 

 

Do not use alcohol to clean parts, 

 

9.6.2.The internal parts of cleaning :( daily) 

In order to eliminate the micro-organisms, cleaning of the inner parts of the cabinet is essential. 
For inner cleaning of a cabinet follow these steps: 
 

 

Clear the foodstuffs from the cabinet, 

 

Switch off power supply of  the cabinet from the main switch, 

 

Remove all the parts such as display trays, (various grids etc) wash and dry carefully. 

 

Clean the bottom tray carefully, 

 

If you notice any abnormal ice than contact with a Qualified Refrigeration Technician. 

 

Inside of the cabinet must be washed with running water and water drain outlet fastened to the floor 

during installation of the cabinet,  

 

9.7.Recommendation : 

 First of all, read the installation and use manual and if any operation problem occurs, call our operator to take 
further assistance. (Unplug the cabinet before carrying out any maintenance operation.) 

Before calling the technical service, check those points below: 

 

Ambient temperature and humidity values should not be exceed the indicated values. 

 

Therefore the air conditioning, ventilation and heating devices in the shop should be working efficiently. 

 

Ambient air speed values near the cabinet opening should be limited with 0,2m/s. 

 

Air stream and air intakes should not be directed towards the cabinet openings and the goods displayed 
should not be exposed to direct sunlight. 

 

Prevent the temperature increment of radiating surfaces in the shop e.g. installation ceiling  

 

Spotlights with incandescent lamps should not be directed towards the cabinet. 

 

The air inlets and vents on the cabinet should not be closed with products, labels, accessories so on. 

 

Only  the  items  which  already  refrigerated  can  be  used  in  the  cabinet  as  the  temperature  that  normally 
characterizes the chain of cold. 

 

The cabinet temperature should remain the same. 

 

Do not overload the cabinet; take the loading limit into consideration. 

 

Considering  the  foodstuff  turnover,  the  first  loaded  goods  should  be  sold  first.  (Apply  first  in  first  out 
procedure.) 

 

Control the displays foodstuff and the operation temperature of the cabinet regularly at least twice a day. 

 

Replace the goods right away, if any failure occurs on the cabinet. 

 

If you find any fault parts, move it right away(burnt out lamps, loosened parts etc) 

 

Control the automatic defrosting of the cabinet regularly. 

 

The draining of the defrost water and the water evaporation has to be checked regularly. 

 

If any unexpected condensation occurs than call a qualified refrigerator technician. 

 

 

Summary of Contents for REYHAN CL

Page 1: ...www ggmgastro com REYHAN CL Display Cases Plug in User Guide Please read manual completely before operate this cabinet...

Page 2: ...abinet Operation 9 8 1 2 Cabinet Control 9 10 8 1 3 Access to fans 10 8 1 4 Access to drainage outlets 10 8 1 5 Access to cabinet electrics and controls 10 8 1 6 Access to probes 10 9 USE OF CABINET 1...

Page 3: ...g The base plate at the bottom of the cabinet is removed By screwing the adjustable feet right and left the height of the cabinets are equalized 3 2 General View of Water Drain and Electrical Connecti...

Page 4: ...nsult the circuit diagrams that are supplied with each cabinet when carrying out the electrical connections and observe all of your country s safety regulations in full Before plugging into the mains...

Page 5: ...lone Pressed together Up More Than 3 s toggle ON OFF ON OFF Down More Than 3 s toggle defrost ON OFF Set mute 1 s display set the setpoint more than 3 s acess parameter setting menu enter posword 22 M...

Page 6: ...and 8 for all desired parameters 10 Keep SET button pressed for 5 s Controller will visualize temperature read by probes again Attention now parame ters updating will be active 4 1 5 Acessing and sett...

Page 7: ...ic phases 0 1 1 F1 Fans shutdown temperature 50 0 130 0 2 C F F2 Fans OFF when compressor OFF 0 1 1 F3 Fans status during defrost 0 fan ON 1 fan OFF 0 1 1 H OTHER SETTINGS H2 Enable keypad 0 keypad di...

Page 8: ...5 ELECTRICAL PANEL Electrical panels are placed in the bottom of the cabinet as shown on the picture They are located in a waterproof electrical junction box enclosure in order to provide maximum safe...

Page 9: ...t Furniture 25 Bottom Air Baffle 42 Shutter Kit 9 Front Plating Sheet 26 Rear Bottom Sheet 43 Chassis Side Sheet 10 Front Glass 27 Rear Blowing Kit 44 Side Panel Sheet 11 Glass Holding Kit 28 Rear Top...

Page 10: ...ng Fans and Drain Area WHO WHAT REDUCTION Training in correct method Fans protected by guards Cleaning personnel Bending down low Training in correct method Others in area Scratch and impact Clean whe...

Page 11: ...en working inside the condensing unit the power supply must be switched off 8 1 6 Access to probes The ambient probe and defrost probes are now accessible 9 USE OF CABINET 9 1 Transportation GGM gastr...

Page 12: ...es and incandescent light Assemble the adjustable feet after removing the wood pallets Utilize a level and position horizontally Make sure that the ventilation openings of the condensing unit are not...

Page 13: ...ing the technical service check those points below Ambient temperature and humidity values should not be exceed the indicated values Therefore the air conditioning ventilation and heating devices in t...

Page 14: ...leveled Under normal conditions if the above are fulfilled the cabinet should start working appropriately After the digital thermostat is set 24 hours should be given for the desired temperature 9 9 S...

Page 15: ...ct of ignition of such a flammable m ixture can be severe It is therefore important that the appropriate safety requirements are observed at all times when working with flammable refrigerants All tool...

Page 16: ...circumstances should equipment operation be re instated with faulty electrical components If it is essential to maintain an active power supply to the equipment during the repair activities it is rec...

Page 17: ...scent lamps should not be directed towards the cabinet The air inlets and vents on the cabinet should not be closed with products labels accessories so on The items which pre refrigerated are suggeste...

Page 18: ...d wiring Train the staff who use the cabinet Cabinet temperature is too much or too low Poor ambient conditions Evap are frozen Evap is obstructed The products are not placed evenly on shelves Digital...

Reviews: