9.8.In case of breakdowns:  

If a failure occurs on display refrigerators make sure that the reason of the failure is not improper maintenance. 
If a failure is occurred for any other reason than the possible reasons below please contact with our after sales 
technical services.   

Some reasons for a breakdown and fixing instructions are given below. 

a)

 

If the cabinet is not working and stopping continuously; 

 

Check if the electric is disconnected. 

 

Check if the starting switch is on and the working lamp is illuminated. 

 

Check if the electric cable is connected properly.  

 

If there is no electricity for any other reason, call the nearest technical service. 

If any breakdown occurs or if the electric power is cut and the work of the cabinet is interrupted 
for a certain period of time, all the food products should be taken out and transferred to a cooling 
room to keep the temperature of the food products fixed. 

b)

 

If the fridge is not cooling appropriately; 

 

Check if the display area of the cabinet is filled properly so that the air holes are not blocked 
and there is no excessive load. 

 

If the cabinet is not defrosted for more than 6 hours, the ice should be melt (defrost) and it 
should be cleaned before starting operation again.   

 

Check if the cabinet is away from air circulation (ventilators, windows or open doors) and 
heaters. 

 

Check with a spirit-level if the cabinet is appropriately leveled. 

 

Under normal conditions if the above are fulfilled the cabinet should start working appropriately. After 
the digital thermostat is set, 24 hours should be given for the desired temperature.   
 

9.9.Safety instructions:  

Follow the instructions below in a case of gas escape or fire: 

 

If there is gas escape from the refrigerator, ventilate the room. If it cannot be ventilated leave 
the room.  The cooling gas is not poisonous but contains oxygen and may result in suffocate 
symptoms. 

 

In case of fire turn the cabinet off from its starting switch. Only use dry fire extinguishers to 
take out the fire. Never use water. 

9.10.Controls : 

Connect electricity to start the refrigerator and turn the starting switch on. The working lamp will turn on 
when  it  starts  to  work.  To  illuminate  the  display  area,  turn  on  the  illumination  switch  (inside  the  lamp 
area). Check if the set value is appropriate for food products. For appropriate cooling the set value can be 
changed. When ice in the refrigerator is melting the defrost lamp turns on.  

9.11.Maintenance : 

See  if  the  electricity  is  disconnected  from  the  display  refrigerator  and  it  is  turned  off  before  any 
maintenance or cleaning process. Appropriate gloves have to be used during maintenance or cleaning.  

a)

 

All internal or external parts should be cleaned with a warm water and neutral soap weekly. Dry 
the  area  carefully  with  a  soft  cloth;  never  use  flammable,  poisonous  or  corrosive  cleaning 
products. Never use water jets to clean the cabinet. Drainages are installed in the cabinet to drain 
the water from melting and cleaning and a cup for liquid is used to collect the excess water and 

Summary of Contents for REYHAN CL

Page 1: ...www ggmgastro com REYHAN CL Display Cases Plug in User Guide Please read manual completely before operate this cabinet...

Page 2: ...abinet Operation 9 8 1 2 Cabinet Control 9 10 8 1 3 Access to fans 10 8 1 4 Access to drainage outlets 10 8 1 5 Access to cabinet electrics and controls 10 8 1 6 Access to probes 10 9 USE OF CABINET 1...

Page 3: ...g The base plate at the bottom of the cabinet is removed By screwing the adjustable feet right and left the height of the cabinets are equalized 3 2 General View of Water Drain and Electrical Connecti...

Page 4: ...nsult the circuit diagrams that are supplied with each cabinet when carrying out the electrical connections and observe all of your country s safety regulations in full Before plugging into the mains...

Page 5: ...lone Pressed together Up More Than 3 s toggle ON OFF ON OFF Down More Than 3 s toggle defrost ON OFF Set mute 1 s display set the setpoint more than 3 s acess parameter setting menu enter posword 22 M...

Page 6: ...and 8 for all desired parameters 10 Keep SET button pressed for 5 s Controller will visualize temperature read by probes again Attention now parame ters updating will be active 4 1 5 Acessing and sett...

Page 7: ...ic phases 0 1 1 F1 Fans shutdown temperature 50 0 130 0 2 C F F2 Fans OFF when compressor OFF 0 1 1 F3 Fans status during defrost 0 fan ON 1 fan OFF 0 1 1 H OTHER SETTINGS H2 Enable keypad 0 keypad di...

Page 8: ...5 ELECTRICAL PANEL Electrical panels are placed in the bottom of the cabinet as shown on the picture They are located in a waterproof electrical junction box enclosure in order to provide maximum safe...

Page 9: ...t Furniture 25 Bottom Air Baffle 42 Shutter Kit 9 Front Plating Sheet 26 Rear Bottom Sheet 43 Chassis Side Sheet 10 Front Glass 27 Rear Blowing Kit 44 Side Panel Sheet 11 Glass Holding Kit 28 Rear Top...

Page 10: ...ng Fans and Drain Area WHO WHAT REDUCTION Training in correct method Fans protected by guards Cleaning personnel Bending down low Training in correct method Others in area Scratch and impact Clean whe...

Page 11: ...en working inside the condensing unit the power supply must be switched off 8 1 6 Access to probes The ambient probe and defrost probes are now accessible 9 USE OF CABINET 9 1 Transportation GGM gastr...

Page 12: ...es and incandescent light Assemble the adjustable feet after removing the wood pallets Utilize a level and position horizontally Make sure that the ventilation openings of the condensing unit are not...

Page 13: ...ing the technical service check those points below Ambient temperature and humidity values should not be exceed the indicated values Therefore the air conditioning ventilation and heating devices in t...

Page 14: ...leveled Under normal conditions if the above are fulfilled the cabinet should start working appropriately After the digital thermostat is set 24 hours should be given for the desired temperature 9 9 S...

Page 15: ...ct of ignition of such a flammable m ixture can be severe It is therefore important that the appropriate safety requirements are observed at all times when working with flammable refrigerants All tool...

Page 16: ...circumstances should equipment operation be re instated with faulty electrical components If it is essential to maintain an active power supply to the equipment during the repair activities it is rec...

Page 17: ...scent lamps should not be directed towards the cabinet The air inlets and vents on the cabinet should not be closed with products labels accessories so on The items which pre refrigerated are suggeste...

Page 18: ...d wiring Train the staff who use the cabinet Cabinet temperature is too much or too low Poor ambient conditions Evap are frozen Evap is obstructed The products are not placed evenly on shelves Digital...

Reviews: