Voc marked on the module should be multiplied by a factor of 1.25 when determining voltage ratings,
conductor current ratings, fuse sizes, and size of other system components.
Always respect the polarity of the connectors when stringing modules, and make sure the connectors
are tightly connected. Do not install or wire modules when the connectors are wet.
Grounding
Grounding of the modules needs to be done in accordance with the applicable regional regulations about
grounding PV arrays and mounting frames.
Maintenance
Screw tightness and corrosion at the mounting points, as well as wiring connectivity should be
regularly inspected.
Periodic cleaning of modules is recommended, but is not required. Rainfall will give the module its
self-cleaning capabilities. Please not that GH Solar is not responsible for any yield losses due to
pollution on the panel, caused by a too small slope.
Modules may be cleaned by potable, non-heated water. Normal water pressure is sufficient. No
cleaning products are to be used and heavily sticking impurities are to be removed by a soft cleaning
tool like a sponge or cleaning cloth. Use of cleaning chemicals or sharp instruments to clean the
modules will damage the module, and therefore invalidate the product warranty.