www.ghibliwirbel.com
Professional Cleaning Machines Since 1968
EN
- 14
Standard configuration with Sonnen
-
schein gel batteries
- Remove the cap (49) located under the
batter charger (16).
- Position the switches (DP1 and DP2) as
shown in figure “
A
”.
It is possible to modify the configuration as
follows:
Configuration for gel batteries which are
not Sonnenschein version
- Remove the cap (49) located under the
battery charger (16).
- Position the switches (DP1 and DP2) as
shown in figure “
B
”.
Configuration for acid batteries
- Remove the cap (49) located under the
battery charger (16).
- Position the switches (DP1 and DP2) as
shown in figure “
C
”.
TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
The machine will not start if
you turn the key selector to
ON
.
Low battery.
Damaged key block.
Main fuse blown.
Damaged battery plug.
Check that the battery is
charged.
Replace.
Replace the main 30A or
75A fuse.
Replace.
The brush does not rotate.
Function card damaged.
Brush motor damaged.
Brush button damaged or
not pressed.
Replace.
Replace.
Push the button or replace it.
Aspirator does not work.
Function card damaged.
Intake motor damaged.
Suction unit button damaged
or not pressed.
Recovery tank full.
Blocked suction filter.
Replace.
Replace.
Push the button or replace it.
Empty, wash and clean the
tank and the probes.
Clean the filter.
PROBLEM
CAUSE
SOLUTION
The machine does not dry
well, leaving traces of water
on the floor.
Suction motor defective.
Aspiration tube blocked.
Dirty wiper.
Recovery tank full.
Dirty water filter clogged.
Squeegee rubber blades
worn.
Replace the motor.
Check and if necessary
clean the aspiration tube that
connects the squeegee to
the recovery tank.
Clean the wiper.
Empty the recovery tank.
Clean the filter.
Replace or turn over the
squeegee rubber blades.
No water comes out.
Tank empty.
Tap turned off.
Filter blocked.
Solenoid valve does not
work.
Fill the tank.
Open the tap
Clean the filter.
Call the technical support
service.
Insufficient floor cleaning.
Unsuitable brushes or deter-
gent.
Brush worn.
Use brushes or detergents
which are suitable for the
type of floor or dirt to be
cleaned.
Replace the brush.
The brush does not rotate.
Aspirator does not work.
No water comes out.
Defective sensor.
Replace.
Man_round-rapid_ROUND45SM-SD-Rapid_3ed_01-2019_49026700.indd 14