4.4.2
PAB Status LEDs on the Back Panel
Located on the back panel of the
KH Director
are another two LEDs
that provide information about PAB connection status and PAB
communication status..
The upper yellow LED indicates proper communication within the
PAB
connection. The lower
green LED provides information about the status of the
PAB
communication.
Status
Meaning
Yellow LED flashes
KH Director
receives
PAB
commands
Green LED is ON
KH Director
is ready for operation
Green LED flashes quickly
KH Director
is started, firmware update
Green LED flashes every second,
yellow LED is OFF
KH Director
has not received PAB commands from
ProfiLux, GHL Doser SA
or
GHL Doser Maxi SA
for more
than 30 seconds
Both LEDs are OFF
KH Director
has no supply voltage
4.5
Installing the KH Director
The device must be protected from water at all times!
Mount the
KH Director
in a water-protected area. When selecting the mounting material,
make sure that you have adequate sizing and stability. Make sure that the unit cannot fall
into the water during assembly or normal use.
If the device is placed inside an aquarium cabinet, make sure that it is placed in an area free
from splashing water; moisture or liquids that can penetrate.