9. 

Returns

 

The legal regulations for environmental protection and our personnel re-
quire  that  devices  which  are  sent  back  which  have  come  into  contact 
with liquid are handled without risk to people or the environment. 

 

 

 

If you send a device back to us for inspection or repair, we must request that you 
strictly observe the following requirements: 

 

On the GHM homepage under 'Downloads/forms' a return shipment form can be 
downloaded. 

 

The repair can be performed quickly and without call-back questions if: 

 

1. a filled-in form is provided for each device, 

 

2. the device has been cleaned and packaging which prevents damage to the   
    device 

 

3. a safety data sheet for the measuring medium is affixed to the outside of the 
    package, if the device has come into contact with a critical substance. 

 

10. 

Disposal 

Separation by material and recycling of device components and 
packaging must take place when the device is disposed of. The valid legal 
regulations and directives applicable at the time must be observed. 

The device may not be disposed of with household waste. If the device should be 
disposed of, return it to us with the return shipment form filled in the chapter 
'Returns'. We will then arrange for the proper disposal. 

 

11 

Imprint 

GHM Messtechnik GmbH 
Standort Martens, Kiebitzhörn 18, 22885 Barsbüttel 
Managing Director: Günther Oehler 
Registered office: Schloßstr. 6, 88453 Erolzheim / Germany 

Ulm District Court, Commercial Register Section B 730462 

Copyright: GHM Messtechnik GmbH. All rights reserved. Reprints, digital use of any 
type,  and  duplication  may  only  take  place  with  the  written  authorisation  of  GHM 
Messtechnik GmbH.  

 

 

DANGER

 

Summary of Contents for 125L

Page 1: ...Operating manual Universal transmitter UT125 Save for later reference www ghm messtechnik de Companies brands of GHM English ...

Page 2: ...2 Product description 5 2 1 Scope of delivery 5 2 2 Functional principle 6 2 3 Connection diagram 6 2 4 PowerRail 7 2 5 Type plate 8 3 Assembly and installation 9 3 1 Mechanical assembly 9 3 2 Electrical installation 9 4 Controls and functional description 10 5 Commissioning maintenance and service 11 5 1 Commissioning 11 5 2 Maintenance 11 5 3 Service 11 6 Technical data 12 6 1 Mechanical design ...

Page 3: ...hen used improperly or not as intended The device is not intended for use in explosion prone areas and safety related system parts in accordance with SIL General safety instructions use This operating manual must be kept in a location such that qualified personnel can refer to it at all times Any processes described in this operating manual may only be carried out by trained qualified personnel wh...

Page 4: ...to ensure conformity with the described device However deviations cannot be entirely ruled out Therefore we cannot assume any guarantee for complete conformity The specifications in this document are checked regularly and any necessary corrections are incorporated into subsequent versions This document is subject to technical changes In addition all claims are based on the valid Standard Terms for...

Page 5: ...tures and potentiometer into a current signal of 4 20 mA The universal configurability of the measuring inputs reduces the stock requirement for various applications The measuring inputs and analog output are not galvanically isolated The housing width of only 12 5 mm enables space saving installation in the switch cabinet 2 1 Scope of delivery UT125 this operating manual further documents if appl...

Page 6: ...tion takes place via DIP switch The power supply can be provided via an internal wide range power supply 20 125 V DC 20 253V AC or via a DC voltage power supply with 24 V DC With the DC voltage power supply the power supply can be done via the plug in device terminals or via a carrier rail bus PowerRail on the device depending on the device type 2 3 Connection diagram Input signals should be conne...

Page 7: ...alent version is available for the entire LP series of GHM carrier rail devices in 12 5mm wide housing Before mounting the device to be supplied a series compatible bus adapter must be connected on the carrier rail For this purpose an adapter piece is required for each device The supply of the bus then takes place via a plug in terminal strip In the device version UT125LP provided for this purpose...

Page 8: ...arsbüttel Germany Phone 49 40 670 73 0 Fax 288 www ghm messtechnik de info martens elektronik de 8 2 5 Type plate The type plate includes the most important identification data Type and article name Technical data Serial number bar code Fig 3 Type plate ...

Page 9: ...r rails 3 2 Electrical installation The device may only be installed by an electrician The national and international regulations for connection of electrical systems in the respective user country apply Power supply in accordance with DIN EN 60664 1 SELV PELV Observe the connection diagram for installation of the inputs and outputs The supply voltage is connected to pins 11 and 12 of the plug in ...

Page 10: ...tiometer Pt100 thermocouple The black fields symbolize the position of the DIP switches When voltage and current are injected simultaneously the result is an addition of the input related signals The respective limit values can be adjusted with wheels A1 and A2 The illuminated scales serve as an operating indicator When a limit value relay is not active the adjustment wheel scale illuminates green...

Page 11: ... scale lighting blinks red The analog output drops to approx 0mA 5 Commissioning maintenance and service 5 1 Commissioning 1 Ensure that the connection assignment takes place according to the connection diagram and matches the supply voltage 2 Ensure that the terminals are firmly screwed in 3 After switching on the power check to ensure the correct device function 5 2 Maintenance Housing No cleani...

Page 12: ...rent approx 1 6 mA Thermocouple linearized with reference junction compensation optional without internal compensation Resistance Potentiometer 3 wire rated value 500 Ω 20 kΩ internal reference voltage approx 1 5 V Analog output 4 20 mA max burden 400 Ω burden failure at 400 Ω max 0 2 No galvanic isolation from the input signal Input signal Basic precision analog output Temperature deviation 0 2 1...

Page 13: ...08 mm Material PA6 6 light grey flammability class V0 UL94 Weight 120 g Protection rating IP20 Screw terminals 0 2 2 5 mm AWG 24 14 removable coded Push in terminals 0 5 1 5 mm AWG 25 16 double connection spring terminals 12A between the connections removable coded Power rail 8A over the entire bus system Supply via removable terminals 0 2 2 5 mm AWG 24 14 6 1 Mechanical design dimensions ...

Page 14: ...4V DC 15 with Carrier rail bus connection 125M Wide range power supply 20 125VDC 20 253V AC 2 Options 00 No options 01 Push in terminals plug in Supply including matching bus adapter piece see chapter PowerRail 8 Device transport and storage Gentle and tension free packaging of the housing must be ensured for transport no machine wrapping of the package The device must be stored in the environment...

Page 15: ... safety data sheet for the measuring medium is affixed to the outside of the package if the device has come into contact with a critical substance 10 Disposal Separation by material and recycling of device components and packaging must take place when the device is disposed of The valid legal regulations and directives applicable at the time must be observed The device may not be disposed of with ...

Page 16: ...GHM Messtechnik GmbH Martens Kiebitzhörn 18 22885 Barsbüttel Germany Phone 49 40 670 73 0 Fax 288 www ghm messtechnik de info martens elektronik de 16 12 Certificate of Conformity V 01 00 02 ...

Reviews: