3.
Assembly and installation
3.1.
Mechanical assembly
Carrier rail mounting TS35, DIN EN 60715
The mounting of multiple devices without spaces is only permitted on horizontally
mounted carrier rails.
3.2.
Electrical installation
The device may only be installed by an electrician. The national and
international regulations for connection of electrical systems in the
respective user country apply.
Power supply in accordance with DIN EN 60664-1, SELV, PELV.
Observe the connection diagram for installation of the inputs and outputs.
The supply voltage is connected to pins 11 and 12 of the plug-in terminal strip.
Terminals 41, 42, 51 and 52 are provided for sensor connection.
Terminals 61 and 62 are provided for analog output.
DANGER
Fig. 4