HD2010UC
- 99 -
V4.2
ANNEX
A1. HD2010UC MEASURING
PARAMETERS
In the next paragraphs, are shown the acoustic parameters that can be displayed in numeric or
graphic format, with the respective abbreviations used to identify them.
A
COUSTIC DESCRIPTORS
(N
UMERIC
D
ISPLAY
)
Instantaneous acoustic levels refreshed every 0.5s
Wideband
PARAMETER
ABBREV.
DEFINITION
WEIGH.
FREQ.
WEIGH.
TEMP.
L
Xeq(Short)
L
eqS
dBX
Short equivalent level (0.5s)
X=Z, C, A
-
L
XYp
L
Yp
dBX
Sound pressure level (SPL)
X=Z, C, A
Y=F, S, I
L
Xpk
L
pk
dBX
Instantaneous peak level
X=Z, C
-
Integrated acoustic levels
Wideband
PARAMETER
ABBREV.
DEFINITION
WEIGH.
FREQ.
WEIGH.
TEMP.
L
Xeq
L
eq
dBX
Equivalent continuous level
X=Z, C, A
-
L
XYmax
L
Ymx
dBX
Sound pressure maximum level (SPL
max
)
X=Z, C, A
Y=F, S, I
L
XYmin
L
Ymn
dBX
Sound pressure minimum level (SPL
min
)
X=Z, C, A
Y=F, S, I
L
Xpkmax
L
pkmx
dBX
Peak maximum level
X=Z, C
-
L
nn
Li, i=1÷4
nn%
nn% percentile with nn=1÷99
A
F
A weighting
PARAMETER
ABBREV.
DEFINITION
WEIGH.
FREQ.
WEIGH.
TEMP.
L
AE
L
E
dBA
Exposure level throughout the measure-
ment time (SEL)
A
-
Dose %
A
Dose
%
Dose percentage with programmable ex-
change rate, threshold level and criteria
A
-
Dose %
A,d
Dose,d
%
Daily estimated dose with programmable
exchange rate, threshold level and criteria
A
-
LAIeq
LeqI
dBA
A weighted equivalent continuous level
with Impulse time constant
A
I
Other
PARAMETER
ABBREV.
DEFINITION
WEIGH.
FREQ.
WEIGH.
TEMP.
Overload %
OL%
Percentage of the measurement time in
which an overload occurs
-
-
2
The maximum reached level every 0.5s is displayed.
3
It is possible to program up to 4 different percentile levels.