Malfunction
Possible cause(s)
Remedy
No display
Display not correctly attached
Take the display off and attach it again (see
section 10, Riding the EPAC, point 1
)
Rechargeable battery pack flat
Charge the rechargeable battery pack (see
section 8.5.1, Charging the rechargeable
battery pack)
Rechargeable battery pack broken
Please contact your specialist bicycle
dealer.
Cables damaged
Please contact your specialist bicycle
dealer.
Rechargeable
battery pack
cannot be charged
up
Rechargeable battery pack broken
Please contact your specialist bicycle
dealer.
Charging device broken
Please contact your specialist bicycle
dealer.
Drive not working
Fault in the control system
Carry out a fault diagnosis in accordance
with
section 15.6.2
.
Rechargeable battery pack flat
Charge the rechargeable battery pack (see
section 8.5.1, Charging the rechargeable
battery pack)
Rechargeable battery pack broken
Please contact your specialist bicycle
dealer.
Cables damaged
Please contact your specialist bicycle
dealer.
Speed is over 25 km/h
The drive is designed to switch off at
speeds over 25 km/h.
Drive does not
supply enough
power
Control system fault
Calibrate the drive in accordance with
section 8.5.2.
Rechargeable battery pack almost flat
Charge the rechargeable battery pack (see
section 8.5.1, Charging the rechargeable
battery pack)
Motor temperature too high due to
excessive load
Stop at an appropriate location and wait
until the motor has cooled down.
Otherwise the power of the drive is
reduced until the motor temperature has