GHP Group, Inc.
Model: Large Wood Stove
Report Number:0418WS018E
OMNI-Test Laboratories, Inc.
Table 10 – Test Configurations
Run
Startup Procedures
Combustion Air
1
Fuel Loading: Kindling and start-up fuel loaded together; a torch was used
for 20 seconds to establish a fire. At 45 minutes placed fuel load into the
firebox and closed the loading door. Loading required less than 1 minute to
complete.
Door: For kindling and start-up fuel, loading door was closed by 30 seconds.
Test fuel load: fuel loading door was closed by 1:00 minute and 35 seconds.
Primary Air: Air control fully open for the entire test.
Fan: Turned to high 5 minutes after lighting fire, on high remainder of test.
Bypass: Open until 20 seconds after lighting kindling, not used for test fuel
load loading.
Fully open for
entire test.
2
Fuel Loading: Test fuel loaded onto coal bed generated by test number 1 by
53 seconds.
Door: Closed by 3 minutes and 32 seconds.
Primary Air: Fully open until 5 minutes and 36 seconds then set to half open.
At 12 minutes and 14 seconds set to 0.03” from fully closed.
Fan: Off for first 12 minutes and 14 seconds, then turned to high for
remainder of test.
Bypass: Not used.
Fully open for first
5 minutes 36
seconds, then set
to half open. At
12 minutes 14
seconds set to
0.03” from full
closed.
3
Fuel Loading: Kindling and start-up fuel loaded together; a torch was used
for 30 seconds to establish a fire. At 41 minutes placed fuel load into the
firebox and closed the loading door. Loading required less than 1 minute to
complete.
Door: For kindling and start-up fuel, loading door was closed by 35 seconds.
Test fuel load: fuel loading door was closed by 1:00 minute and 30 seconds.
Primary Air: Air control fully open for the entire test.
Fan: Turned to high 5 minutes after lighting fire, on high remainder of test.
Bypass: Open until 35 seconds after lighting kindling, not used for test fuel
load loading.
Fully open for
entire test.
4
Fuel Loading: Test fuel loaded onto coal bed generated by test number 1 by
60 seconds.
Door: Closed by 3 minutes and 30 seconds.
Primary Air: Fully open until 4 minutes and 45 seconds then set to half open.
At 10 minutes and 45 seconds set to fully closed.
Fan: Off for first 10 minutes and 45 seconds, then turned to high for
remainder of test.
Bypass: Not used.
Fully open for first
3 minutes 30
seconds, then set
to half open. At
10 minutes 45
seconds set to full
closed.
10 of 142
Summary of Contents for GWS-2200
Page 26: ...26 of 142 ...
Page 35: ...35 of 142 ...
Page 36: ...36 of 142 ...
Page 55: ...55 of 142 ...
Page 56: ...56 of 142 ...
Page 64: ...64 of 142 ...
Page 65: ...65 of 142 ...
Page 73: ...73 of 142 ...
Page 74: ...74 of 142 ...
Page 78: ...78 of 142 ...
Page 79: ...79 of 142 ...
Page 80: ...80 of 142 ...
Page 81: ...81 of 142 ...
Page 82: ...82 of 142 ...
Page 83: ...83 of 142 ...
Page 84: ...84 of 142 ...
Page 85: ...85 of 142 ...
Page 86: ...86 of 142 ...
Page 88: ...88 of 142 ...
Page 89: ...89 of 142 ...
Page 90: ...90 of 142 ...
Page 91: ...91 of 142 ...
Page 94: ...94 of 142 ...
Page 97: ...97 of 142 ...
Page 98: ...98 of 142 ...
Page 99: ...99 of 142 ...
Page 138: ...227 of 229 ...
Page 139: ...228 of 229 ...
Page 140: ...229 of 229 ...