OMNI-Test Laboratories, Inc.
C
s
- Concentration of particulate matter in tunnel gas, dry basis, corrected to standard conditions, g/dsc
ASTM E2515 equation (13)
Where:
K
2
=
Constant, 0.001 g/mg
m
n
=
Total mass of particulate matter collected in the sampling train, mg
V
m(std)
=
Volume of gas sampled corrected to dry standard conditions, dscf
Sample calculation:
For Train 1:
5.1
74.99
C
s
=
0.00007
g/dscf
For Train 2
4.6
79.42
C
s
=
0.00006
g/dscf
For Ambient Train
0.0
0
C
r
=
0
g/dscf
C
s
=
0.001 x
C
s
=
0.001 x
C
r
=
0.001 x
)
(
2
std
m
n
s
V
m
K
C
u