Fueling instructions for use with ASTM E3053-17
GHP Large with By-Pass High Burn Proced
ure
Kindling:
Kindling weight in total should be 3.5lbs (±0.5bs) ten pieces in total of equal size,
15-17’’ in length. Making sure the weight doesn’t exceed what’s allowed per the
standard.
Start-up Fuel:
The start-up fuel consists of ten pieces of equal size with a total weight of 5.5lbs
(±0.5lbs) and a length of 15-17’’.
Test Fuel:
The test fuel consists of five pieces with a nominal length of 16’’. Follow the fuel
sheet guideline for specific weights of the core and remainder loads.
Test fuel:
Start-up Procedure:
The start-up fuel is comprised of six layers as follows. All kindling pieces are
placed in between the start-up pieces. A small handful of tiny kindling pieces are
20 of 142
Summary of Contents for GWS-2200
Page 26: ...26 of 142 ...