Manufacturer:
GHP Group
Technician Signature:
Model:
GHP Large
Date:
05/06/20
Run:
4
Control #:
0418WS018E
Test Duration:
480
Output Category:
II
HHV Basis
LHV Basis
Overall Efficiency
76.6%
82.1%
Combustion Efficiency
95.1%
95.1%
Heat Transfer Efficiency
81%
86.3%
Output Rate (kJ/h)
17,282
16,394
(Btu/h)
Burn Rate (kg/h)
1.17
2.57
(lb/h)
Input (kJ/h)
22,556
21,397
(Btu/h)
Test Load Weight (dry kg)
9.33
20.56
dry lb
MC wet (%)
18.07009558
MC dry (%)
22.06
Particulate (g )
0.53
CO (g)
640
Test Duration (h)
8.00
Emissions
Particulate
CO
g/MJ Output
0.00
4.63
g/kg Dry Fuel
0.06
68.62
g/h
0.07
80.03
lb/MM Btu Output
0.01
10.76
Air/Fuel Ratio (A/F)
13.47
VERSION:
2.2
12/14/2009
Test Results in Accordance with CSA B415.1-09
Wood Heater Efficiency Results - CSA B415.1
71 of 142
e:
415.1
Summary of Contents for GWS-2200
Page 26: ...26 of 142 ...
Page 35: ...35 of 142 ...
Page 36: ...36 of 142 ...
Page 55: ...55 of 142 ...
Page 56: ...56 of 142 ...
Page 64: ...64 of 142 ...
Page 65: ...65 of 142 ...
Page 73: ...73 of 142 ...
Page 74: ...74 of 142 ...
Page 78: ...78 of 142 ...
Page 79: ...79 of 142 ...
Page 80: ...80 of 142 ...
Page 81: ...81 of 142 ...
Page 82: ...82 of 142 ...
Page 83: ...83 of 142 ...
Page 84: ...84 of 142 ...
Page 85: ...85 of 142 ...
Page 86: ...86 of 142 ...
Page 88: ...88 of 142 ...
Page 89: ...89 of 142 ...
Page 90: ...90 of 142 ...
Page 91: ...91 of 142 ...
Page 94: ...94 of 142 ...
Page 97: ...97 of 142 ...
Page 98: ...98 of 142 ...
Page 99: ...99 of 142 ...
Page 138: ...227 of 229 ...
Page 139: ...228 of 229 ...
Page 140: ...229 of 229 ...