GHP Group, Inc.
Model: Large Wood Stove
Report Number:0418WS018E
Table 4 – Test Facility Conditions
Run
Room Temperature
(°F)
Barometric Pressure
(Hg)
Air Velocity
(ft/min)
Before
After
Before
After
Before
After
1
75
78
29.43
29.41
<50
<50
2
76
75
29.35
29.45
<50
<50
3
68
78
29.74
29.74
<50
<50
4
77
77
29.74
29.76
<50
<50
Table 5 – Kindling and Start-up Fuel Description Summary
Cherry Cordwood
Note: Test 3 was a high burn used to create a coal bed for test number 4, no particulate sampling
occurred during this test.
Run
Kindling
Weight
Wet Basis
(lbs)
Start-up
Fuel Weight
Wet Basis
(lbs)
Residual
Start-up
fuel weight
(lbs)
1
4.00
6.0
2.2
3
3.80
5.50
2.1
8 of 142
Summary of Contents for GWS-2200
Page 26: ...26 of 142 ...
Page 35: ...35 of 142 ...
Page 36: ...36 of 142 ...
Page 55: ...55 of 142 ...
Page 56: ...56 of 142 ...
Page 64: ...64 of 142 ...
Page 65: ...65 of 142 ...
Page 73: ...73 of 142 ...
Page 74: ...74 of 142 ...
Page 78: ...78 of 142 ...
Page 79: ...79 of 142 ...
Page 80: ...80 of 142 ...
Page 81: ...81 of 142 ...
Page 82: ...82 of 142 ...
Page 83: ...83 of 142 ...
Page 84: ...84 of 142 ...
Page 85: ...85 of 142 ...
Page 86: ...86 of 142 ...
Page 88: ...88 of 142 ...
Page 89: ...89 of 142 ...
Page 90: ...90 of 142 ...
Page 91: ...91 of 142 ...
Page 94: ...94 of 142 ...
Page 97: ...97 of 142 ...
Page 98: ...98 of 142 ...
Page 99: ...99 of 142 ...
Page 138: ...227 of 229 ...
Page 139: ...228 of 229 ...
Page 140: ...229 of 229 ...