3
0201EN
03/2021
M
anifold
cabinets
and
supports
P
lastic
cabinet
with
cover
r595
Installation of R587 coplanar manifolds
1.
To install the R587 3/4” or 1”
coplanar manifolds, use the
R598Y009
accessory which
includes:
• n° 2 supports for coplanar
manifolds
• n° 4 holders for R587 coplanar
manifolds
• n° 2 self-tapping screws.
2.
Follow the steps below to install the manifolds inside the cabinet:
• First, install (whenever possible) the accessories (ex. caps, reducer
fittings, air vents, shut-off valves, etc.) on the R587 manifold.
3.
Place the assemblies inside the cabinet to find the proper location
for the two connection supports (we recommend using the internal
positions closer to the two ends of the manifold).
4.
Place the R598Y009 supports inside the cabinet.
5.
Fit the assembly inside the cabinet.
R593D
R88I
R587
R850
R292
R473M
R178, R179, R179AM
R595 + R598
Installation of R580C-R585C modular manifolds
1.
To install the R580C-R585C
modular manifolds, use the
R598Y007
accessory.
Warning.
R595 cabinets can contain only 3/4” manifolds with a 35-mm center
distance.
R580C-R585C manifolds (3/4”, 35-mm center distance) are also fit for
installation in R595 cabinets using the
R598Y007
special supports.
In such situations, the supports should be connected to the cabinet fixed
rails; that is why only manifolds with a 35-mm center distance can be
installed. The cover can be opened and closed by loosening or tightening
the special screws included with the cabinet.
R595
R598
Example
R585C/2 + R585C/3
R595
R259D
R585C/3
R594
This example shows R585C manifolds with R594 end caps and R259D ball
valves assembled inside the R595 cabinet.
Two R585C manifolds (one 2-outlet ma one 3-outlet manifold) have
been installed in line for domestic cold water to obtain a total of 5 outlets
serving the related usage points.
Only one 3-outlet manifold has been used instead for domestic hot water
usage points.