background image

4

0201EN  

03/2021

M

anifold

 

cabinets

 

and

 

supports

P

lastic

 

cabinet

 

with

 

cover

r595

• 

Modular/bar man zone valves

R595A

R595B

R595C

R66A manual air vent, R292E zone valve with 

R473/R473M actuator, R250D shut-off valves,

R18 3-piece fitting

-

4 + 4

10 + 10

R66A manual air vent, R292E zone valve with 

R473/R473M actuator, R250D shut-off valves,

R18 3-piece fitting

-

4 + 4

10 + 10

R88I or R99I automatic air vent, R292E zone 

valve with R473/R473M actuator, R250D shut-off 

valves, R18 3-piece fitting

-

4 + 4

10 + 10

R88I or R99I automatic air vent, R292E zone 

valve with R473/R473M actuator,

R250D shut-off valves

-

4 + 4

10 + 10

R66A manual air vent, R278E zone valve with 

K270/K272 actuator, R250D shut-off valves, 

R18 3-piece fitting

-

4 + 4

10 + 10

R66A automatic air vent, R278E zone valve 

with K270/K272 actuator,

R250D shut-off valves

-

4 + 4

10 + 10

R88I or R99I automatic air vent, R278E zone 

valve with K270/K272 actuator,

R250D shut-off valves, R18 3-piece fitting

-

4 + 4

10 + 10

R88I or R99I automatic air vent, R278E zone 

valve with K270/K272 actuator,

R250D shut-off valves

-

4 + 4

10 + 10

Installation instructions

• 

Modular/bar manifolds

R595A

R595B

R595C

DN25 modular manifolds (3/4” end pieces)

.../5

.../9

.../13

3/4” bar manifolds (35-mm center distance)

.../5

.../9

.../12(*)

Including 3/4” shut-off valves (R259D, R919, R603 or R604) o end cap.
Enough space to add an R18 3/4” 3-piece fitting or fittings suitable for the 
various types of synthetic pipes.

R595A

R595B

R595C

DN25 modular manifolds (1” end pieces)

.../4

.../8

.../12

1” bar manifolds (35-mm center distance)

.../4

.../8

.../12(*)

Including 1” shut-off valves (R259D or R919) and end cap.
Enough space to add an R18 1” 3-piece fitting or fittings suitable for the 
various types of synthetic pipes.

• 

Modular/bar man R554I automatic air vent

R595A

R595B

R595C

DN25 modular manifolds (3/4” end pieces)

.../3

.../7

.../11

3/4” bar manifolds (35-mm center distance)

.../3

.../7

.../12

Including 3/4” shut-off valves (R259, R919, R603 or R604) and R554I 3/4” 
end piece. Enough space to add an R18 3/4” 3-piece fitting or fittings suit-
able for the various types of synthetic pipes.

R595A

R595B

R595C

DN25 modular manifolds (1” end pieces)

.../2

.../6

.../10

1” bar manifolds (35-mm center distance)

.../2

.../6

.../12

Including 1” shut-off valves (R259D or R919) and R554I 3/4” end piece.
Enough space to add an R18 1” 3-piece fitting or fittings suitable for the 
various types of synthetic pipes.

• 

Modular/bar man R66A manual air vent

R595A

R595B

R595C

DN25 modular manifolds (3/4” end pieces)

.../4

.../8

.../12

3/4” bar manifolds (35-mm center distance)

.../4

.../8

.../12

Including 3/4” shut-off valves (R259D, R919, R603 or R604) and R66A man-
ual air vent. Enough space to add an R18 3/4” 3-piece fitting or fittings 
suitable for the various types of synthetic pipes.

R595A

R595B

R595C

DN25 modular manifolds (1” end pieces)

.../3

.../7

.../11

1” bar manifolds (35-mm center distance)

.../3

.../7

.../12

Including 1” shut-off valves (R259D or R919) and R66A manual air vent.
Enough space to add an R18 1” 3-piece fitting or fittings suitable for the 
various types of synthetic pipes.

Summary of Contents for R595 Series

Page 1: ...nsidered when choosing a flush mount cabinet R595 cabinets enable the installer to assess right away their versatility and convenience during laying and installation while saving precious time They are also fit for installation of Giacomini s complete range of manifolds thanks to the use of the R598 special quick connection supports sold separately Versions and product codes Product code Dimension...

Page 2: ...nd DN25 modular manifolds use the R598Y004 accessory which includes n 2 inclined supports for upper manifold n 2 straight supports for lower manifold n 4 fasteners 2 Follow the steps below to install the manifolds inside the cabinet First install whenever possible the accessories ex caps reducer fittings air vents shut off valves etc on the two manifolds Installation of 3 4 bar manifolds 3 Note us...

Page 3: ... R598 Installation of R580C R585C modular manifolds 1 To install the R580C R585C modular manifolds use the R598Y007 accessory Warning R595 cabinets can contain only 3 4 manifolds with a 35 mm center distance R580C R585C manifolds 3 4 35 mm center distance are also fit for installation in R595 cabinets using the R598Y007 special supports In such situations the supports should be connected to the ca...

Page 4: ...us types of synthetic pipes R595A R595B R595C DN25 modular manifolds 1 end pieces 4 8 12 1 bar manifolds 35 mm center distance 4 8 12 Including 1 shut off valves R259D or R919 and end cap Enough space to add an R18 1 3 piece fitting or fittings suitable for the various types of synthetic pipes Modular bar manifolds R554I automatic air vent R595A R595B R595C DN25 modular manifolds 3 4 end pieces 3 ...

Page 5: ...a prodotti giacomini com This document provides only general indications Giacomini S p A may change at any time without notice and for technical or commercial reasons the items included herewith The information included in this datasheet do not exempt the user from strictly complying with the rules and good practice standards in force Giacomini S p A Via per Alzo 39 28017 San Maurizio d Opaglio NO...

Reviews: