Figure 11
Figure 12
Figure 15
Figure 16
Figure 14
Figure 13
Figure 11~13: Showing an operator installation for a minimum door leaf width and a maximum opening angle.
The opening angle is recommended not excess to 120°.
Figure 14: Automatic door operator dimension
Install AD425S on an out-swing door, make sure that the distance between the header and leaf is not more
than 61 mm, and the space between the header and Sliding Rail mounting hole must be 60mm. (See Figure
15)
Install AD425S on an in-swing door, make sure that the distance between Square Couplings and hinge is
not more than 74mm , the space between header and the bottom of AD425S must be 23mm, and the space
between header and Sliding Rail mounting hole must be 39mm (See Figure 16)
All dimensions and units are in millimeters unless otherwise specified.
Make sure AD425S performance is effectively; no extra door closer required.
Warning: The AD425S installation should regard the external and internal pressure conditions. To
assure the proper operation and the finest performance, please make a regular check for your
operator.
Automatic Door Operator
Manual
10
(Min.) 750mm
(Min.) 750mm