background image

 

Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG25  Ver. B  Publish:2008.08.01                                                             Page: 2/ 3

 

3.  The indicator signal chart: 

Sound and LED indicator:  

Green LED

  

Power on, stand-by  

Red LED

 

Relay 1 activated 

LED signal 

Yellow LED 

Relay 2 activated 

1 Beep 

Effective PIN codes 

2 Beeps 

Entering 

Exiting from the Program mode 

3 Beeps 

Data computing error 

 other operation mistakes 

Sound signal 

5 Beeps 

Master Code reset to Factory 

12345

 

 
 

4. Operation Instruction: 

 

‹

  Enter Program Mode:  

1.  Compose twice the master code (Factory master is 

12345

)  

 2 beeps 

 you are now in the "programming mode". 

2.  After 60 seconds if you have not entered any codes or data, the system will 

automatically exit from the programming mode. After 32 wrong codes attempts at the 
master code the lockout facility will operate. 

 

‹

  Exiting from the program mode: 

1. Press

#

 to exit from the programming mode. 

2.  After 60 seconds if you have not entered any codes or data, the system will 

automatically exit from the programming mode. After 32 wrong codes attempts at the 
master code the lockout facility will operate. 

 

‹

  Add PIN codes  

Enter the Programming mode, Enter the slot position code 

「*

001~

099

????? 

Input 5 digit PIN codes

 (beep) enrolled 

Æ

repeat

 

Press 

#

 to exit from the programming mode, or program other operating. 

Note 1:

 The codes

00000

,

12345

or master code are not be used for PIN code. 

Note 2:

 Relay 1 is controlled by 001~049 user slots, Relay 2 is controlled by 050~099 

user slots 

 

‹

  To Delete a User Code

 

         

Enter the Programming mode

 Press the slot position code of your choice to delete 

(example "06") 

Press

「*

006

00000

beep

delete

Press

#

 to exit 

from the programming mode, or programming other operating.

  

       

 

 

‹

  To Program Relocking Timer 

        

Enter the Programming mode, 

A. Relay 

1

Press

「*

100

Followed by the number of seconds the relay should 

open

05

=5 seconds

01 ~99 = seconds

beep

enrolled 

 Press 

#

 to exit from the programming mode, or program other operating. 

B. Enter

00

Sets the relay to latching mode.

 

(Correct code entered opens the relay, 

and the relay stays open until the correct code is entered again). 

C. Relay 

2

Press

「*

200

Followed by the number of seconds the relay should 

open

05 =5 seconds (01 ~99 = seconds).  

beep

enrolled 

 Press 

#

 to exit from the programming mode, or program other operating. 

D. Enter

00

Sets the relay to latching mode.

 

(Correct code entered opens the relay, 

and the relay stays open until the correct code is entered again). 

 

Reviews: