background image

Copyright © Gianni Industries, Inc. All Rights Reserved. 
P-MU-EASIPROX-N Published on  2019.03.26                                                                                                                                    Page: 2/ 4

 

IV. Wiring Diagram 

For DC use only

 

Note: 

1. It is suggested to use #22~26 AWG insulation wire. 
2. It is suggested to use a linear power supply unit to prevent the reduction of reading range. 
3. The door strike or relay must have a varistor or a diode across the door strike terminals to suppress the

back EMF of the strike. Failure to do so will damage the relay contacts and electronic components, or  
even burn the controller. 

4. The exit button input can be wired to a normally open push button to activate the relay.

V. Operation Instructions

1. Programming Master Card

    Yellow and Green LED flash indicate that the memory is empty. Present a new card to the reader to set
    as the "Master Card" (Yellow LED turns on and reader enters standby mode). The first card presented to
    the reader is Master Card.
    Note: The same Master Card can be used on more than one reader.  

 

2. Adding User Cards

   1. Present Master Card to the reader (Green LED turns on for 3 seconds and flashes, and reader enters 
       ADD CARDS mode)

Note: It is suggested to use cards with ABA form codes and make a list of all added cards.

3. Deleting User Cards

1. Present Master Card twice with a time between reads of less than 2 seconds (Red LED turns
    on for 3 seconds and flashes, and reader enters DELETE CARDS mode).
2. Present the user card (Green LED turns on and then the user card is deleted).
3. Present Master Card again (Red LED turns off, Yellow LED turns on, and reader goes back to standby mode).

Red

Green

Red

Green

White

Yellow

Blue

For AC/DC

12 VDC

Com.

Black

All settings are cleared

N.C.

Black

All settings are cleared

N.O.

Exit button input

Exit button input

12 VDC

Electrified lock1

(Fail-safe)

Electrified lock2

(Fail-secure)

(Polarity Insensitive)

(Polarity Insensitive)

2. Present a new user card to the reader (Relay is activated when a new card is added to memory).
3. Present Master Card to the reader again (Green LED turns off, Yellow LED turns on, and reader goes 
    back to standby mode).

Clearing Memory