Copyright © Gianni Industries, Inc. All Rights Reserved.
P-MU-EASIPROX-N Published on 2019.03.26 Page: 3/ 4
4. Clearing Memory
1. Present Master card 3 times with a time between reads of less than 2 seconds (Yellow and Red LED turn
on 3 seconds and flash, and reader enters CLEAR MEMORY mode).
2. Present any card with EM-400x64-bit format except Master Card (Green LED quickly flashes indicating
that clearing memory is in progress).
3. Wait until Yellow and Green LED flash, then all memories are cleared, and all settings are reset to factory
values.
4. Program a new Master Card.
If the Master Card is lost, follow the steps bellow to clear memory:
1. Turn off the power.
2. Connect the two black cables and turn on the power (Green LED flashes indicating that clearing memory
is in progress).
5. Setting Relock Time
1. Present Master Card 4 times with a time between reads of less than 2 seconds (All LEDs go off for 3
seconds, Yellow LED flashes and reader enters RELOCK TIME SETTING mode).
Note: The relock time can be set up to 60 seconds so the Yellow LED flashes up to 60 times. After 60 flashes, the
Yellow LED stays on and reader goes back to standby mode.
VI. TS-980 Tag Simulator(Optional)
The Tag Simulator is an extremely simple "Programming Device" that allows adding and deleting proximity
card/tag numbers from reader memory when the tag is lost or not available.
For example: To delete a card printed with a decimal number "0001206932," press
continuously. When
the screen displays displays
, press
→
, and press
→
.
Repeat the preceding step. When the screen displays
, press
the Tag Simulator and the reader must be within 3 cm). Card deletion is completed.
Send
Send card No.
Skip over next digit
Power
Decimal
ABA form code, decimal
Warranty
The product is warranted against defects in material and workmanship while used in normal service for
a period of 1 year from the date of sale to the original customer. The GEM policy is one of continual
development and improvement; therefore GEM reserves the right to change specifications without
notice.
3. Disconnect the two black cables (Yellow and Green LED flash indicating that all memories are empty).
Modulation 0 to 9
2. Each flash of the Yellow LED indicates 1 second.To set the relock time to 5 seconds, present Master Card after
5 flashes of the Yellow LED (Yellow LED stays on and reader goes back to standby mode).
On/Off
(The distance between