LED Indicators & Keypad Sounds
Operation Instruction
Jumper Setting
Copyright All Rights Reserved. P-MU-DG-15LD Published:2020.11.25
Blue On
Green On
Amber On
1 Beep
2 Beeps
3 Beeps
5 Beeps
Power on, Stand by
Relay 1 active
Relay 2 active
Valid key press
Enter, exit setting mode
Incorrect operation
Master Code back to 12345
(Cleared settings)
5 digit
4 or 5 digit setting
4 digit
Copyright All Rights Reserved. P-MU-DG-15LD Published:2020.11.25
Blue + Green + Amber
Programming mode
RESET
4OR5
Normal
Reset
1. Default value: “1234” for 4 digits, “12345” for 5 digits
It’s suggested to clear all stored codes prior to new setting.
2. Master Code reset to default value”12345”:
3. Clear all PINs:
Specifications
12-key keypad (0~9,
*
,
#
)
3 LED indicators display
(Power: Blue, Relay 1: Green, Relay 2: Amber)
1 Contact for Request-To-Exit button
1 Contact for door reed switch
Non-volatile memory protects programmed information in
case of power loss.
EPROM
Memory Volume
Output
Input
LED Status Indication
Keypad
Ambient Humidity
Operating Temperature
0%~95% (Non-condensing)
-20ºC~+70ºC
2 relays (Dry contacts: N.O./N.C./Com.)
01~99 seconds or Toggle Mode (00)
Relay 1 is controlled by user
*
001~
*
200
(*
300
)
Relay 2 is controlled by user
*
201~
*
210
(*
301
)
Sign: Relay1(
*
300); Relay2(
*
301)
12~24 VDC
Relay Electric Current
3A/120VDC , 3A/24VDC
Operating Voltage
Current Draw
Active: 90mA/12VDC, Standby: 40mA/12VDC
Active: 120mA/24VDC, Standby: 60mA/24VDC
Relay Strike Time
200+10 PINs (
*
001~
*
210)
Digital Keypad Operation Manual
LED
Beep
Master Code reset to
default value"12345"
a. Insert the jumper into 1-2 (5 beeps)
b. Master Code reset to default value
c. Insert the jumper into 2-3
a. Reset Master Code to default value (5 beeps, clearing all PINs)
b. Insert the jumper into 2-3
a - Enter Programming Mode
Enter the master code twice (Default value: “1234” or “12345) to enter programming
mode (2 beeps)
Note: 1. After 60 seconds if no data entered, the keypad will automatically exit the
programming mode.
2. The controller will be locked for 60 seconds upon 30 consecutive wrong master
code entries.
79
mm
125
mm
55
mm
64
mm
DG-15LD