background image

 

 

29-LX ALIGNMENT 

REVISION: 00 

ENG-29-LX-08 

 

4. 

Alignment of WX receiver portion. 

4.0 

Equipment required: 
A: Signal generator 
B: AC voltmeter. 
C: Oscilloscope. 
D: Dummy load ( 8 ohm, 5 watts, resistive.) 
E: DC power supply ( 13.8 v. 2Amp.) 

4.1 

Alignment procedure: 

TEST ITEM 

TEST CONDITION & PROCEDURE 

1. AUDIO OUTPUT 

1. Set channel 5. RF connect to the TP4. 
2.

 

Set the S.G. on 10.7MHz with 1KHz, 

±3

KHz mod. and 1mV output level. 

3. CB/WX/PA to WX. Volume set 
approximately Center. 

2. RX Sensitivity 

1.

 

Set RF output connect to the TP1. 

2.

 

Set the S.G. on 162.450MHz with 1KHz, 

±3

KHz mod. RF output level 1.0uV. 

3. Tone Decoder Sens. 

1. Set unit off, RF output @1.2uV, AF 

(Turn-on): @

±4

KHz 

@1050Hz, RF Freq @162.450MHz 

 
 
 
 
 
 
 
 
 
 

PURPOSE 

1.

 

Adjust 

L604

 for maximum  

2. audio output & minimum distortion on  
  the distortion meter. 

 
 

1.

 

Adjust 

L603

 & 

L602

 for more  

  than 12dB to the SINAD meter.  
  Repeat as needed. 
1.  The  unit  will  turn on  automatically  when  
  RF signal open.  

 

 

5. 

Alignment of Transmitter portion. 

5.1 

Equipment Required: 

A: VTVM ( full scale: 1V DC with RF probe). B: 
RF power meter.  
C: Spectrum analyzers.  
D: Frequency counter.  
E: DC power supply. (13.8VDC / 3AMPs)  
F: 50 ohm load and attenuator.  
G: Oscilloscope.  
H: AF generator.  

5.2 

Alignment procedure: 

TEST ITEM 

TEST CONDITION & PROCEDURE 

PURPOSE 

1. TP4 output 

1.

 

Connect the oscilloscope to the TP4. 

Adjust 

L20, 21, 17

for maximum 

2.

 

Set TX mode , Channel 19. 

output on the oscilloscope. 

2. TX power 

1. Set TX Channel 19. 

1.

 

Adjust 

L17,14

 for maximum 

output on the RF power meter.  

2.

 

Turn 

L14

 to obtain 4.0W on the RF  

  meter reading. 

3. TX carrier frequency 

1. Set TX Channel 19. 

 

4. Second harmonic 

1. Set TX Channel 19. 

 

5. “P4” indicator 

1. Set TX Channel 19. 

 

6. Modulation 

1.

 

Set TX Channel 19. 

2. AF GEN. Output 30mV. 

7. Talk-back 

1. Set unit in TX mode with 90% Mod. 

1.

 

Adjust 

L24

 to obtain 27.185MHz on 

the frequency counter. 

1.

 

Adjust 

L11

 for a min. 2

nd

 harmonic  

  ( 54MHz) output on the Spectrum anal.  

1.

 

Adjust 

VR5 

for “P4” display at the TX  

  Signal meter of the LCD meter.  

1.

 

Adjust 

VR4

 for 90% on the  

  modulation Meter. 
1.  The speaker can be heard the tone when  
  Talkback turn on.  

 
 

Page: 5 / 6 

print date: 10-6-22 

Reviews: