background image

12/18   GP7132_GP7136.indd

GIANT INDUSTRIES, INC.

 900 N. Westwood Ave., Toledo, Ohio  43607              

Phone: (419)-531-4600  FAX (419)-531-6836, www.giantpumps.com

 

Copyright 2018 Giant Industries, Inc.

GIANT INDUSTRIES LIMITED WARRANTY

Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from 
defects in workmanship and material as follows:
 

1.  For portable pressure washers and self-serve car wash applications, the discharge  

 

 

manifolds will never fail, period. If they ever fail, we will replace them free of charge.  

 

 

Our other pump parts, used in portable pressure washers and in car wash applications,  

 

 

are warranted for five years from the date of shipment for all pumps used in NON- 

 

 

SALINE, clean water applications.

 

2.    One (1) year from the date of shipment for all other Giant industrial and consumer  

 

 pumps.

 

3.    Six (6) months from the date of shipment for all rebuilt pumps.

 

4.    Ninety (90) days from the date of shipment for all Giant accessories.

                   
This warranty is limited to repair or replacement of pumps and accessories of which  
the  manufacturer’s evaluation shows were defective at the time of shipment by the manufacturer.  
The following items are NOT covered or will void the warranty:
 

1.   Defects caused by negligence or fault of the buyer or third party.

 

2.    Normal wear and tear to standard wear parts.

 

3.   Use of repair parts other than those manufactured or authorized by Giant.

 

4.   Improper use of the product as a component part.

 

5.   Changes or modifications made by the customer or third party.

 

6.   The operation of pumps and or accessories exceeding the specifications set forth  

 

 

in the Operations Manuals provided by Giant Industries, Inc.

Liability under this warranty is on all non-wear parts and limited to the replacement or repair of those 
products returned freight prepaid to Giant Industries which are deemed to be defective due to work-
manship or failure of material.  A Returned Goods Authorization (R.G.A.) number and completed 
warranty evaluation form is required prior to the return to Giant Industries of all products under war-
ranty consideration.  Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number.

Repair or replacement of defective products as provided is the sole and exclusive remedy provided 
hereunder and the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, 
OR EXPENSES, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR 
INDIRECTLY ARISING FROM THE SALE OR USE OF THIS PRODUCT.

THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR 
REPRESENTATION, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WAR-
RANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH 
WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER.  

Summary of Contents for GP7132

Page 1: ...nstallation Instructions page 2 GP7132 Pump Specifications page 3 Exploded View page 4 Parts List Kits page 5 GP7136 Pump Specifications page 6 Repair and Service pages 7 9 Torque Specs page 9 Trouble Shooting Chart page 10 Recommended Spare Parts List page 10 Dimensions page 11 Warranty Information back page ...

Page 2: ...bore situated next to the eye bolt 31 2 The inlet to the pump should be sized for the flow rate of the pump with no unnecessary restrictions that can cause cavitation Teflon tape should be used to seal all joints If pumps are to be operated at temperatures in excess of 140o F it is important to insure a positive head to the pump to prevent cavita tion 3 The discharge plumbing from the pump should ...

Page 3: ... gallons 6 0 L Fluid End Material Stainless Steel Volumetric Efficiency 700 RPM 94 Mechanical Efficiency 700 RPM 83 GP7132 Pump Specifications HORSEPOWER RATINGS The rating shown are the power requirements for the pump Gas engine power outputs must be approximately twice the pump power require ments shown above We recommend a 1 15 service factor be speci fied when selecting an electric motor as th...

Page 4: ...4 Exploded View GP7132 and GP7136 Pumps ...

Page 5: ...re Ring GP7132 3 41 06795 Pressure Ring GP7136 3 42 06096 V Sleeve GP7132 6 42 06796 V Sleeve GP7136 6 43 06097 Sleeve Support Ring GP7132 3 43 06797 Sleeve Support Ring GP7136 3 45 06098 Tension Spring 3 49 13159 Stud Bolt 8 49A 13160 Nut 8 50 06798 Valve Casing 1 51 04727 Inlet Valve Assembly 3 51B 05193 O Ring 3 51C 04725 Inlet Valve Seat 3 51D 13130 Valve Plate 3 51E 07062 0100 Valve Spring 3 ...

Page 6: ...Material Stainless Steel Volumetric Efficiency 700 RPM 94 Mechanical Efficiency 700 RPM 83 GP7136 Pump Specifications HORSEPOWER RATINGS The rating shown are the power requirements for the pump Gas engine power outputs must be approximately twice the pump power require ments shown above We recommend a 1 15 service factor be speci fied when selecting an electric motor as the power source To compute...

Page 7: ...Valve seats 51C and 52C are pressed out of spacer pipe 51F by hitting the valve plate 51D 52D with a bolt 4 Check surfaces of valve plate 51D 52D valve seat 51C 52C O rings 51B 52B and re place worn parts 5 When reassembling The suction valve seat 51C is 1mm smaller in diameter than the dis charge valve seat 52C Suction valve seats are marked S and always have to be installed first Discharge valve...

Page 8: ... 38A or support rings 38B are damaged replace with new parts 38A 38B 38 38B 38A 36 10 Take tension spring 45 and seal pack 41 42 43 out of seal sleeve Take a thin screw driver and pry out the grooved ring 39A Note This seal 39A will not be reusable so replace with a new part For the seal pack 41 43 remove with either a socket wrench or use a screw driver to push against the rear lip of the pressur...

Page 9: ...er removing the circlip ring 33B lever out seal retainer 33 with a screw driver Check seals 32 32A 33A and surfaces of crosshead 16 Remove crankcase cover 4 Loosen inner hexagon screws on the connecting rods 24 and push con rod halves as far into the crosshead guide as possible IMPORTANT Connecting rods are marked for identification Do not twist con rod halves Con Rod is to be reinstalled in the s...

Page 10: ...rop leaks correctly sized inlet plumbing to pump Accumulator pressure Recharge Replace accumulator Unloader Check for proper operation Cavitation Check inlet lines for restrictions and or proper size Pump Pressure as Restricted discharge plumbing Re size discharge plumbing to Drop at gun flow rate of pump Rated Pressure Excessive Worn plungers Replace plungers Leakage Worn packing seals Adjust or ...

Page 11: ...11 GP7132 and GP7136 Dimensions Inches mm ...

Page 12: ...ormal wear and tear to standard wear parts 3 Use of repair parts other than those manufactured or authorized by Giant 4 Improper use of the product as a component part 5 Changes or modifications made by the customer or third party 6 The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries Inc Liability under this warran...

Reviews: