background image

GIANT INDUSTRIES, INC.

, 900 N. Westwood Ave., Toledo, Ohio  43607

PHONE (419) 531-4600, FAX (419) 531-6836, www.giantpumps.com

 

Copyright 2020 Giant Industries, Inc.

GIANT INDUSTRIES LIMITED WARRANTY

Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from 

defects in workmanship and material as follows:

 

1.  For portable pressure washers and car wash applications, the discharge mani 

 

 

folds will never fail, period. If they ever fail, we will replace them free of charge. Our  

 

 

other pump parts, used in portable pressure washers and in car wash applica 

 

 

tions, are warranted for five years from the date of shipment for all pumps used in  

 

 

NON-SALINE, clean water applications.

 

2.    One (1) year from the date of shipment for all other Giant industrial and consumer  

 

 pumps.

 

3.    Six (6) months from the date of shipment for all rebuilt pumps.

 

4.    Ninety (90) days from the date of shipment for all Giant accessories.

                   

This warranty is limited to repair or replacement of pumps and accessories of which the  manufac-

turer’s evaluation shows were defective at the time of shipment by the manufacturer.  The following 

items are NOT covered or will void the warranty:

 

1.   Defects caused by negligence or fault of the buyer or third party.

 

2.    Normal wear and tear to standard wear parts.

 

3.   Use of repair parts other than those manufactured or authorized by Giant.

 

4.   Improper use of the product as a component part.

 

5.   Changes or modifications made by the customer or third party.

 

6.   The operation of pumps and or accessories exceeding the specifications set forth  

 

 

in the Operations Manuals provided by Giant Industries, Inc.

Liability under this warranty is on all non-wear parts and limited to the replacement or repair of 

those products returned freight prepaid to Giant Industries which are deemed to be defective due to 

workmanship or failure of material.  A Returned Goods Authorization (R.G.A.) number and completed 

warranty evaluation form is required prior to the return to Giant Industries of all products under war-

ranty consideration.  Call (419)-531-4600 or fax (419)-531-6836 to obtain an R.G.A. number.

Repair or replacement of defective products as provided is the sole and exclusive remedy provided 

hereunder and the MANUFACTURER SHALL NOT BE LIABLE FOR FURTHER LOSS, DAMAGES, 

OR EXPENSES, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES DIRECTLY OR 

INDIRECTLY ARISING FROM THE SALE OR USE OF THIS PRODUCT.

THE LIMITED WARRANTY SET FORTH HEREIN IS IN LIEU OF ALL OTHER WARRANTIES OR 

REPRESENTATION, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRAN

-

TIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ALL SUCH 

WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED BY THE MANUFACTURER.

  

02/20    LP200-SS.indd

Summary of Contents for LP200-SS

Page 1: ...e 5 Repair Instructions pages 6 9 Torque Specifications page 9 Pump Mounting Selection Guide page 9 Trouble Shooting page 10 Maintenance Spare Parts List page 10 Dimensions page 11 Warranty Informatio...

Page 2: ...l cir cumstances be consulted with regard to the resistance of the pump material It is the re sponsibility of the equipment manufacturer and or operator to ensure that all pertinent safety regulations...

Page 3: ...fied when selecting an electric motor as the power source To compute specific pump horsepower requirements use the following formula HP GPM X PSI 1440 PULLEY INFORMATION Pulley selection and pump spee...

Page 4: ...4 Exploded View LP200 SS...

Page 5: ...IPTION QTY 30 07779 Drip Shield 3 31 07133 Radial Shaft Seal 3 35 13196 Seal Sleeve 3 36 13228 Leakage Seal 3 37 07170 Seal Case 3 38 07140 O Ring 3 38A 12055 O Ring 3 39 13197 Pressure Ring 3 40 1311...

Page 6: ...Take out discharge valve assemblies 46 by pull ing them upwards out of the valve casing 43 with a snap ring tongs or any other pull off device Then remove inlet valves in the same way 4 Loosen valve...

Page 7: ...rface of plunger 25 thoroughly Apply a thin coat of Loctite to the tension screw threads 29C Note Care must be taken that no glue gets between the plunger pipe 29B and the centering sleeve 29A Add new...

Page 8: ...to 59 ft lbs 80 Nm LP200 SS Torque Specifications Position Item Description Lubrication Info Torque Amount 1 07759 Crankcase Molycote Cu Paste 6 05943 Oil Sight Glass Loctite 572 29 ft lbs 40 Nm 10 01...

Page 9: ...aring ring until the outer edge lines up with the outer edge of the bearing hole Remove bearing cover 14 together with radial shaft seal 15 and o ring 16 Fit crank shaft 22 through bearing hole on the...

Page 10: ...riction Check system for stoppage air Pressure Drop leaks correctly sized inlet plumbing to pump Accumulator pressure Recharge Replace accumulator Unloader Check for proper operation Cavitation Check...

Page 11: ...11 Pump Dimensions Inches mm...

Page 12: ...tear to standard wear parts 3 Use of repair parts other than those manufactured or authorized by Giant 4 Improper use of the product as a component part 5 Changes or modifications made by the customer...