9
12) Check plunger surface (29B). If plunger pipe is worn out,
loosen tension screws (29C) with a 15mm socket and
pull off plunger pipe to the front. Clean front surface of
plunger (29B) thoroughly. Apply a small drop of locktite
to tension screw. Put a
new
crush washer (29D) onto
tension screw. Put a thin coat of glue (Loctite) on the ring
(or ceramic plunger side) and tighten screw to 265 in.-lbs.
(30 NM).
29B
29D
29C
13) Replace complete seal
sleeve (35)/seal case (37)
assembly into crankcase
(1). Make sure that the
weep hole points down-
ward.
Note: To replace
the oil seals (31), you
will need to disassemble
the gear end (see in-
structions below).
Weep Hole
14) Place entire manifold/seal
sleeve assembly over the
studs and push firmly until
seated against the crank-
case.
15) Tighten hex nuts (49A) in a
crosswise pattern (shown
above) to 59 ft.-lbs.
6
4
2
7
8
1
3
5
REPAIR INSTRUCTIONS -
LP301A/LP301A-4000/LP600/LP600-4000