Preventative Maintenance Check-List & Recommended Spare Parts List

Check

Daily

Weekly

50hrs

Every

       Every

        Every

500 hrs

      1500 hrs

       3000 hrs

Oil Level/Quality

X

Oil Leaks

X

Water Leaks

X

Belts, Pulley

X

Plumbing

X

Recommended Spare Parts

Oil Change

X

     X

Seal Spare Parts (1 kit/pump)

            X

(See page 11 for kit list)
Oil Seal Kit (1 kit/pump)

            X

(See page 11 for kit lit)

Valve Spare Parts (1 kit/pump)

            X

(See page 11 for kit list)

PUMP SYSTEM MALFUNCTION

MALFUNCTION

CAUSE

REMEDY

The Pressure and/

Worn packing seals

Replace packing seals

or the Delivery

Broken valve spring

Replace spring

Drops

Belt slippage

Tighten or Replace belt

Worn or Damaged nozzle

Replace nozzle

Fouled discharge valve

Clean valve assembly

Fouled inlet strainer

Clean strainer

Worn or Damaged hose

Repair/Replace hose

Worn or Plugged relief valve on pump

Clean, Reset, and Replace worn parts

Cavitation

Check suction lines on inlet of

pump for restrictions
Unloader

Check for proper operation

Water in crankcase

High humidity

Reduce oil change interval

Worn seals

Replace seals

Noisy Operation

Worn bearings

Replace bearings, Refill crankcase

oil with

 recommended lubricant

Cavitation

Check inlet lines for restrictions
and/or proper sizing

Rough/Pulsating

Worn packing

Replace packing

Operation with

Inlet restriction

Check system for stoppage, air

Pressure Drop

leaks, correctly sized inlet
plumbing to pump

Accumulator pressure

Recharge/Replace accumulator

Unloader

Check for proper operation

Cavitation

Check inlet lines for restrictions
and/or proper size

Pressure Drop at Gun

Restricted discharge plumbing

Re-size discharge plumbing to
flow rate of pump

Excessive

Worn plungers

Replace plungers

Leakage

Worn packing/seals

Adjust or Replace packing seals

Excessive vacuum

Reduce suction vacuum

Cracked plungers

Replace plungers

Inlet pressure too high

Reduce inlet pressure

High Crankcase

Wrong Grade of oil

Giant oil is recommended

Temperature

Improper amount of oil in crankcase

Adjust oil level to proper amount

Summary of Contents for P200A-3100 Series Repair and

Page 1: ...ouble Shooting Guide Recommened Spare Parts List page 14 Dimensions page 15 Warranty Information back page Triplex Ceramic Plunger Pump Operating Instructions Repair and Service Manual Series P200A 31...

Page 2: ...before operation from Giant Industries Inc 4 Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures 1 Prior to initial operation add oil to the crankcase...

Page 3: ...a 1725 RPM motor and B section belts When selecting desired GPM allow for a 5 tolerance on pumps output due to variations in pulleys belts and motors among manufacturers 1 Select GPM required then sel...

Page 4: ...00 PSI 2000 PSI 7 75 5 25 1725 2 1 1 2 1 7 2 2 2 5 2 9 7 75 6 50 1450 2 6 1 4 2 2 2 7 3 0 3 6 7 75 7 25 1750 3 4 1 9 2 8 3 5 4 0 4 7 P218A 3100 5100 PULLEY SELECTION HORSEPOWER REQUIREMENTS PULLEY INF...

Page 5: ...rrect nozzle size that corresponds with the pump GPM HORSEPOWER INFORMATION Horsepower ratings shown are the power require ments for the pump Gas engine power outputs must be approximately twice the p...

Page 6: ...size that corresponds with the pump GPM HORSEPOWER INFORMATION Horsepower ratings shown are the power require ments for the pump Gas engine power outputs must be approximately twice the pump power req...

Page 7: ...ific pump horse power requirements use the following formula HP GPM X PSI 1450 Intermittent duty only U S Metric 1750 RPM Ratings 2 34 GPM 2000 PSI 8 9 LPM 137 bar 3450 RPM Ratings 4 2 GPM 2000 PSI 15...

Page 8: ...ompute specific pump horse power requirements use the following formula HP GPM X PSI 1450 U S Metric 1750 RPM Ratings 2 1 GPM 2000 PSI 8 0 LPM 137 bar 3450 RPM Ratings 3 8 GPM 2000 PSI 14 4 LPM 137 ba...

Page 9: ...operate beyond one or more of the limits specified above Specifications Model P230 3100 5100 U S Metric 1750 RPM Ratings 1 1 GPM 2000 PSI 4 2 LPM 137 bar 3450 RPM Ratings 2 05 GPM 2000 PSI 7 8 LPM 13...

Page 10: ...10 Exploded View P200A 3100 5100 Series...

Page 11: ...d 3 24 07904 Pressure Ring 3 25 08445 0100 Weep Return Ring 316 S S 3 26 06582 3000 Valve Casing 3100 pumps 1 26 06582 5000 Valve Casing 5100 pumps 1 27 07849 0100 Valve Seat 6 28 07491 0100 Valve Pla...

Page 12: ...leeve 23 from the valve casing 26 Remove the rear v sleeve 23A from the seal case 20 Inspect all parts including o ring 21 for wear and replace as necessary 8 Check surfaces of plunger 16 A damaged su...