Specifications

Model P220A-3100/5100

Consult the factory for special requirements that must be met if the pump is
to operate beyond one or more of the limits specified above.

PUMP 

PULLEY

MOTOR 

PULLEY

RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI

7.75

5.25

1150

3.1

1.7

2.6

3.2

3.6

4.3

7.75

6.50

1450

3.9

2.2

3.2

4.0

4.6

5.4

7.75

7.75

1750

4.7

2.6

3.9

4.9

5.5

6.5

P220A-3100/5100 PULLEY SELECTION & HORSEPOWER 

REQUIREMENTS

PULLEY INFORMATION

Pulley selection and pump speed are based on a 1725
RPM motor and "B" section belts.  When selecting
desired GPM, allow for a ±5% tolerance on pumps
output due to variations in pulleys, belts and motors
among manufacturers.
1.

Select GPM required, then select appropriate

motor and pump pulley from the same line.
2.

The desired pressure is achieved by selecting the

correct nozzle size that corresponds with the pump
GPM.

HORSEPOWER INFORMATION
Horsepower ratings shown are the power require-
ments for the pump.  Gas engine power outputs must
be approximately twice the pump power require-
ments shown above.
We recommend that a 1.1 service factor be specified
when selecting an electric motor as the power source.
To compute specific pump horsepower requirements,
use the following formula:

GPM X PSI 

 =hp

1450

U.S.

(Metric)

Volume ........................................................... 4.7GPM* .................. (17.8 LPM)*
Discharge Pressure ........................................ 2000 PSI ................... (140 bar)
Inlet Pressure ................................................. 90 PSI ....................... (6.2 bar)
RPM ................................................................................................... 1750 RPM
Plunger Diameter ........................................... 4.76” ......................... 18mm
Stroke ............................................................. 3.73 ........................... 14.1mm
Temperature of Pumped Fluids ..................... 160

o

F ........................ (71

o

C)

Inlet Ports (P220A-3100) .................................................................. (2) 3/8” BSP
Inlet Ports (P220A-5100) .................................................................. (2) 1/2” BSP
Discharge Ports .................................................................................. (2) 3/8" BSP
Shaft Rotation ................................................ Top of Pulley Towards Fluid End
Crankshaft Diameter ..................................... 0.94” ......................... 24mm
Key Width ...................................................... 0.31” ......................... 8mm
Shaft Mounting .................................................................................. Either Side
Weight ............................................................ 11 lbs. 11oz. .............. (4.9 kg)
Crankcase Oil Capacity ................................. 8.1 fl.oz. .................... (0.24 liters)
Volumetric Efficiency @ 1750 RPM ................................................. 0.96
Mechanical Efficiency @ 1750 RPM ................................................ 0.85

* Positive inlet pressure required

Summary of Contents for P200A-3100 Series Repair and

Page 1: ...ouble Shooting Guide Recommened Spare Parts List page 14 Dimensions page 15 Warranty Information back page Triplex Ceramic Plunger Pump Operating Instructions Repair and Service Manual Series P200A 31...

Page 2: ...before operation from Giant Industries Inc 4 Run the pump dry approximately 10 seconds to drain the water before exposure to freezing temperatures 1 Prior to initial operation add oil to the crankcase...

Page 3: ...a 1725 RPM motor and B section belts When selecting desired GPM allow for a 5 tolerance on pumps output due to variations in pulleys belts and motors among manufacturers 1 Select GPM required then sel...

Page 4: ...00 PSI 2000 PSI 7 75 5 25 1725 2 1 1 2 1 7 2 2 2 5 2 9 7 75 6 50 1450 2 6 1 4 2 2 2 7 3 0 3 6 7 75 7 25 1750 3 4 1 9 2 8 3 5 4 0 4 7 P218A 3100 5100 PULLEY SELECTION HORSEPOWER REQUIREMENTS PULLEY INF...

Page 5: ...rrect nozzle size that corresponds with the pump GPM HORSEPOWER INFORMATION Horsepower ratings shown are the power require ments for the pump Gas engine power outputs must be approximately twice the p...

Page 6: ...size that corresponds with the pump GPM HORSEPOWER INFORMATION Horsepower ratings shown are the power require ments for the pump Gas engine power outputs must be approximately twice the pump power req...

Page 7: ...ific pump horse power requirements use the following formula HP GPM X PSI 1450 Intermittent duty only U S Metric 1750 RPM Ratings 2 34 GPM 2000 PSI 8 9 LPM 137 bar 3450 RPM Ratings 4 2 GPM 2000 PSI 15...

Page 8: ...ompute specific pump horse power requirements use the following formula HP GPM X PSI 1450 U S Metric 1750 RPM Ratings 2 1 GPM 2000 PSI 8 0 LPM 137 bar 3450 RPM Ratings 3 8 GPM 2000 PSI 14 4 LPM 137 ba...

Page 9: ...operate beyond one or more of the limits specified above Specifications Model P230 3100 5100 U S Metric 1750 RPM Ratings 1 1 GPM 2000 PSI 4 2 LPM 137 bar 3450 RPM Ratings 2 05 GPM 2000 PSI 7 8 LPM 13...

Page 10: ...10 Exploded View P200A 3100 5100 Series...

Page 11: ...d 3 24 07904 Pressure Ring 3 25 08445 0100 Weep Return Ring 316 S S 3 26 06582 3000 Valve Casing 3100 pumps 1 26 06582 5000 Valve Casing 5100 pumps 1 27 07849 0100 Valve Seat 6 28 07491 0100 Valve Pla...

Page 12: ...leeve 23 from the valve casing 26 Remove the rear v sleeve 23A from the seal case 20 Inspect all parts including o ring 21 for wear and replace as necessary 8 Check surfaces of plunger 16 A damaged su...

Page 13: ...cting rods 2 Replace left and right side bearings 12A and 12B if they were removed from the crankshaft Be certain the bearings are pressed all the way onto the shaft and completely into the crankcase...

Page 14: ...f pump for restrictions Unloader Check for proper operation Water in crankcase High humidity Reduce oil change interval Worn seals Replace seals Noisy Operation Worn bearings Replace bearings Refill c...

Page 15: ...15 P200A 3100 5100 DIMENSIONS INCHES mm...

Page 16: ...ifications made by the customer or third party 6 The operation of pumps and or accessories exceeding the specifications set forth in the Operations Manuals provided by Giant Industries Inc Liability u...