- 6 -
the radius of the plasma beam.
NOTE! This machine is designed to use only compressed
air as the “gas”.
B. Voltage Regulation
The Automatic Voltage Compensation circuit prevents voltage load from exceeding maximum in
accordance with the main technical data sheet and shortening the life of the machine.
C. Thermal Protection
The thermal protection circuits will engage if unit exceeds duty cycle. This will cause the
machine to stop working. The indicator will be lit on the front of the machine. The fan will most
likely continue to run until unit cools down. When it reaches an acceptable temperature, it will
operate again.
D. Duty Cycle
Duty cycle is the percentage of on time (measured in minutes) in a 10-minute period in which
the machine can be operated continually, in an environment of a specified temperature.
Exceeding duty cycle ratings will cause the thermal overload protection circuit to become
energized and shut down output until the unit cools to normal operating temperature. Continual
exceeding of duty cycle ratings can cause damage to the machine.
E. INPUT POWER
CUT40/50
for 220 voltage input,
CUT40D/50D
for 110/220 duel voltage input, automatic input voltage changing