Oil on the drying agent 

If too many oil particles enter the adsorber, the oil particles close the pores of the desiccant and thus 
prevent adsorption. 

 

Ambient temperature too high 

If the ambient temperature exceeds 80°C, the binding forces in the desiccant decrease. This means that 
the incoming ambient air is only dried to a limited extent. 

 

2.  Positive or negative pressure builds up in the system 

Valves are jammed / blocked 

If the functionality of the valves is impaired by impurities, the pressure in the system increases. 

 

Air flow rate too high 

Too high an air flow rate can cause over- or underpressure in the system. 

 

Contaminated filter element 

The filter unit can be clogged by dirt particles and can therefore build up pressure in the system. 

 

Oil on the drying agent 

If oil particles get into the adsorber, the spaces in the fill can be filled with oil and the fill will stick 
together. This can cause pressure to build up in the system. 

 

3.  Adsorber is damaged 

Material resistance 

When selecting the adsorber, the ambient and operating conditions should be considered. An aggressive 
environment or liquid in the container can damage the adsorber. 

 

Temperature range 

The ambient and operating temperatures should not exceed or fall below the specified range, otherwise 
the adsorber may be damaged. 

 

Improper handling 

Incorrect or improper handling can damage the adsorber. The recommended installation must be 
observed. 

 

Strong vibrations 

Strong vibrations of the plant can damage the adsorber. 

Summary of Contents for ME-RV

Page 1: ...on the manufacturer Giebel FilTec GmbH Carl Zeiss Str 5 74626 Bretzfeld Germany Tel 49 79 46 94 44 01 0 Fax 49 79 46 94 44 01 29 E Mail info giebel adsorber de Section 2 Product overview Sizes Size 2 Size 3 Size 5 ME RV 2L ME RV 3M ME RV 3L ME RV 5M ME RV 5L ME RV 5XL Materials used Stainless steel acrylic glass polyoxymethylene POM FKM EPDM Silicagel Orange activated carbon REACH Note No ingredie...

Page 2: ...ion efficiency Seal material FKM EPDM Operating temperature 40 C 80 C Connection BSP NPT Metric Slipfit Section 4 Technical data ME RV 2L ME RV 3M ME RV 3L ME RV 5M ME RV 5L ME RV 5XL Total weight kg 3 5 4 8 6 1 8 7 10 8 13 2 Adsorbent kg 0 5 0 9 1 4 2 5 3 8 5 2 Max Water absorption ml 200 360 560 1000 1520 2080 Height mm 210 290 390 320 420 520 Housing diameter mm 90 110 110 150 150 150 Screw in ...

Page 3: ...crew it onto the system Remove the safety plugs from the clamps 2 Remove the protective foil on the underside of the adsorber section and place the adsorber section on the valve section 3 Hook the clamping bracket into the closing hooks and press the clamping levers down Secure the clamping lever again with the safety plugs Blue highlighted in the image Adsorbers of the ME RV 2L series have no ext...

Page 4: ...th the new one 4 Remove the activated carbon disc and empty the desiccant 5 Pull out the filter element 6 Remove the lower foam disc as well 7 Loosen the circlip on the inside of the window remove the window and flat gasket Insert the new inspection glass shown in yellow and flat seal shown in red from the inside and reinstall the retaining ring 8 Remove the flat gaskets on the bottom of the adsor...

Page 5: ...ctors Number and duration of flow and loading intervals Air flow volume and flow velocity relative humidity of ambient air Temperature of the ambient air and the medium to be ventilated Storage of adsorbers All articles filled with desiccant are packed airtight To avoid damage to the desiccant they must be stored in dark and dry rooms at 10 C to 30 C Adsorber Spare parts kit Desiccant ME RV 1L ET ...

Page 6: ...fied as a hazardous substance under European Union legislation Regulation EC No 1272 2008 It is not subject to compulsory labelling according to EC Directive 67 548 EEC or 1999 45 EC Silicagel Orange is not classified as a substance hazardous to health or the environment Section 9 Risk and hazard analysis 1 Moist air flows into the system Porous seals Moist air can flow into the adsorber or into t...

Page 7: ...ate too high Too high an air flow rate can cause over or underpressure in the system Contaminated filter element The filter unit can be clogged by dirt particles and can therefore build up pressure in the system Oil on the drying agent If oil particles get into the adsorber the spaces in the fill can be filled with oil and the fill will stick together This can cause pressure to build up in the sys...

Page 8: ...In case of existing damage a new spare parts kit or a new adsorber should be used 2 Check filter unit for impurities Check Take off the lid and remove the activated carbon disc Then empty the desiccant The filter unit can then be removed This should be checked for impurities and should be free of dirt for smooth operation Cycle Half yearly Measures The filter element is part of the spare parts kit...

Page 9: ...es do not open and close replace the adsorber with a new one to ensure full functionality 5 Visual inspection of the adsorber Check The adsorber including the connection must be visually checked for damage Damage can occur due to various environmental or operating conditions Cycle Yearly Measures If the adsorber is damaged it must be replaced completely to ensure full functionality 6 Replacing the...