Press connector 2. Crimp side
-
Shrink with hot-air gun until the insulation
sleeve shrinks (shrink temperature 110 °C)
6.4 Isolation of system cables
-
A current collector that is installed incorrectly or
in the wrong location will leave 2 small holes in
the system cable that must be isolated against
moisture
-
Isolation of the holes (current collector)
Hazard
Insulation tape: Item no. 152743
Manufacturer's designation: 3 M Scotch table no. 23,
black, (19 mm/19.4 m)