6 Maintenance and debugging
6.1 Inspection and maintenance plan
Work to be carried out
Time period/frequency
Function test
In accordance with the country-specific provisions/as
required
Cleaning
If required and according to the degree of dirt
6.2 Description of the inspection and maintenance plan
All functions of the RoadLED must be maintained and, if need be, executed by professionally trained person-
nel, in accordance with the regulations, standards and rules of the respective country.
6.3 Troubleshooting / Measures for fault elimination
Fault / error message
Possible cause
Remedy
LED modules do not light up
Battery discharged
Fuse defective
Interrupted cable
Light module defective
Control unit defective
Charge battery
Replace defective fuse
Check cable and replace damaged sec-
tion if necessary.
Replace the electronics of the light mo-
dule.
Contact the manufacturer GIFAS or
have it checked by a qualified electri-
cian on site.
if required, send in the complete unit.
LED module flickers
Light module connection
may not be tight
Cable break
Contact the manufacturer GIFAS or
have it checked by a qualified electri-
cian on site
If required, send in the light module.
Battery is not being charged
Charger not correctly
connected
Charging cable defective
Plug and socket connec-
tions defective
Temperature too high or
too low
Battery defective
Check charging cable for correct con-
nection.
Check charging cable for damage
Change charging environment or select
cooler or warmer location
Battery capacity indication defective
Send to GIFAS for repair
Battery is not being fully
charged - Battery life too
short
Ageing of the battery and
decrease of the max.
capacity
Battery not fully charged
Send to GIFAS for battery change.
Recharge the battery and charge it oc-
casionally using the battery capacity in-
dication monitoring.
Damage to cable drum
Send to GIFAS for repair