- 89 -
BIOS Setup
5-3-3 UMC Common Options
Parameter
Description
UMC Common Options
DDR4 Common Options
Press [Enter] for more options.
Enforce POR
–
Press [Enter] to configure the enforcement of Plan Of Record
(POR) which enables / disables restrictions for DDR4 frequency
and voltage programming. Memory speeds will be capped at AMD
guidelines.
– To enable 2 DIMMS per Channel at 3200MHz function, select
Accept
at warning message, switch Overclock from
Auto
to
Enabled
, and then set memory speed to 3200Mhz.
DRAM Controller Configuration
–
Press [Enter] to configure DRAM controller options.
•
DRAM Power Options
•
Cmd2T
•
Gear Down Mode
CAD Bus Configuration
–
Press [Enter] to configure CAD Bus options.
•
CAD Bus Timing User Controls
•
CAD Bus Drive Strength User Controls
Data Bus configuration
–
Press [Enter] to configure Data Bus options.