background image

R282-3C2 

3rd Gen. Intel® Xeon® Scalable DP Server System - 2U 12-Bay Gen4 NVMe

User Manual

Rev. 1.0

Summary of Contents for R282-3C2

Page 1: ...R282 3C2 3rd Gen Intel Xeon Scalable DP Server System 2U 12 Bay Gen4 NVMe User Manual Rev 1 0 ...

Page 2: ...cations Inordertoassistintheuseofthisproduct GIGABYTEprovidesthefollowingtypesofdocumentations For detailed product information carefully read the User s Manual For More Information For related product specifications the latest firmware and software and related information please visit ourwebsiteat http www gigabyte com For GIGABYTE distributors and resellers additional sales marketing materials a...

Page 3: ... guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Page 4: ...articular attention to the plug electrical outlet and the point where the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing CAUTION Do not operate the server for l...

Page 5: ...system and discon nect the cables attached to the system before servicing it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist str...

Page 6: ...ke care to grip with but not squeeze the pliers or other tool used to remove a jumper or the pins on the board may bend or break CAUTION Risk of explosion if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions ...

Page 7: ...he CPU and Heat Sink 28 3 3 1 Follow these instructions to install the CPU 28 3 4 Installing the Memory 30 3 4 1 Eight Channel Memory Configuration 30 3 4 2 Installing a Memory 31 3 4 3 DIMM Population Table 31 3 4 4 Processor and Memory Module Matrix Table 32 3 4 5 Intel Optane DCPMM DIMM Population Rule 33 3 5 Installing the PCI Expansion Card 34 3 6 Installing the Hard Disk Drive 35 3 7 Replaci...

Page 8: ...Chipset Menu 75 5 3 1 Processor Configuration 76 5 3 2 Common RefCode Configuration 79 5 3 3 UPI Configuration 80 5 3 4 Memory Configuration 81 5 3 5 IIO Configuration 84 5 3 6 Advanced Power Management Configuration 86 5 3 7 PCH Configuration 88 5 3 8 Miscellaneous Configuration 90 5 3 9 Server ME Configuration 91 5 3 10 Runtime Error Logging Settings 92 5 3 11 Power Policy 94 5 4 Server Manageme...

Page 9: ... 9 5 8 1 PEI Beep Codes 111 5 8 2 DXE Beep Codes 111 ...

Page 10: ... 10 This page intentionally left blank ...

Page 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Page 12: ...3200 2933 2666 MHz LAN 2 x 1Gb s LAN ports Intel I350 AM2 1 x 10 100 1000 management LAN Expansion Slot Riser Card CRS2033 1 x PCIe x16 slot Gen4 x16 Full height half length 2 x PCIe x8 slots Gen4 x8 Full height half length Riser Card CRS2137 1 x PCIe x16 slot Gen4 x16 o x8 Full height half length 1 x PCIe x8 slots Gen4 x0 or x8 Full height half length 1 x PCIe x16 slot Gen4 x16 or x8 shared with ...

Page 13: ... header 1 x HDD back plane board header 1 x IPMB connector 1 x Clear CMOS jumper 1 x BIOS recovery switch Front Panel LED Buttons 2 x USB 3 0 1 x Power button with LED 1 x ID button with LED 1 x Reset button 1 x NMI button 1 x System status LED 1 x HDD activity LED 2 x LAN activity LEDs Rear Panel I O 2 x USB 3 0 1 x VGA 2 x RJ45 1 x MLAN 1 x ID button with LED Backplane I O Front side_CBP20C5 8 x...

Page 14: ...operating temperature 40 C to 60 C Operating humidity 8 80 non condensing Non operating humidity 20 95 non condensing OS Compatibility Windows Server 2016 Windows Server 2019 Windows Server 2022 Red Hat Enterprise Linux 8 2 x64 or later Red Hat Enterprise Linux 8 3 x64 or later SUSE Linux Enterprise Server 12 SP5 x64 or later SUSE Linux Enterprise Server 15 SP2 x64 or later Ubuntu 20 04 LTS x64 or...

Page 15: ...EL Log in Linear Storage Circular Storage Policy Hardware Inventory Fan Profile System Firewall Power Consumption Power Control LDAP AD RADIUS Support Backup Restore Configuration Remote BIOS BMC CPLD Update Event Log Filter User Management Media Redirection Settings PAM Order Settings SSL Settings SMTP Settings System Dimension 2U 438mm W x 87 5mm H x 730mm D We reserves the right to make any cha...

Page 16: ...CIe4 0 x16 PCIe4 0 x32 2 x PCIe 4 0 x8 slots PCIe 4 0 x16 slot PCIe 4 0 x8 slot PCIe 4 0 x8 slot PCIe 4 0 x0 or x8 slot PCIe 4 0 x16 or x8 slot PCIe 4 0 x16 or x8 slot PCIe4 0 x16 PCIe4 0 x24 PCIe4 0 x8 SPI Flash 64 MB SPI Flash 64 MB Dual ROM ROT Option Dual ROM ROT Option 3 x UPI 11 2GT s ICX PCIe4 0 x16 Switch NCSI NCSI OCP 3 0 mezzanine OCP 2 0 mezzanine PCH Lewisburg R Intel C621A 2 x SlimSAS...

Page 17: ... 2 System Appearance 2 1 Front View No Decription 1 Front Panel LEDs and buttons 2 Front USB 3 0 ports NOTE The Green Latch Supports NVMe Please Go to Chapter 2 3 Front Panel LED and Buttons for detail description of function LEDs 1 2 ...

Page 18: ...ezzanine Slot Option OCP 3 0 Card SFF Type 2 ID Button with LED 3 Server management LAN port 4 1GbE LAN port x 2 5 USB 3 0 port x 2 6 Mezzanine Slot Option OCP 2 0 Card 7 VGA port 8 Low Profile PCIe Card Slot 9 Full height 10 Full height 7 8 9 10 2 3 1 4 5 6 ...

Page 19: ...D Button with LED Blue On System identification is active N A Off System identification is disabled 5 HDD Status LED Green On HDD locate Blink HDD access Amber On HDD fault Green Amber Blink HDD rebuilding N A Off No HDD access or no HDD fault 6 System Status LED Green On System is operating normally Amber On Critical condition may indicates System fan failure System temperature Blink Non critical...

Page 20: ...twork or no access Green Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring 8 LAN2 Active Link LED Green On Link between system and network or no access Green Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring ...

Page 21: ...bE Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring 1 2 1 2 2 1 ...

Page 22: ...en ON OFF 2 5 HDD LED 1 LED 2 RAID SKU LED 1 Locate HDD Fault Rebuilding HDD Access HDD Present No Access No RAID configuration via HBA Disk LED LED on Back Panel Green ON 1 OFF BLINK 2 OFF Amber OFF OFF OFF OFF Removed HDD Slot LED on Back Panel Green ON 1 OFF Amber OFF OFF RAID configuration via HW RAID Card or SW RAID Card Disk LED Green ON OFF BLINK 2 OFF Amber OFF ON Low Speed 2 Hz OFF OFF Re...

Page 23: ...G 2Hz Power supply firmware update mode Amber BLINKING 1Hz Power supply warning events where the power supply continues to operate high temperature hihg power high current slow fan Amber Power supply critical event causing a shutdown failure OCP OVP Fan fail AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power 2 6 Power Supply Unit LED ...

Page 24: ...Hardware Installation 24 This page intentionally left blank ...

Page 25: ...you are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to ...

Page 26: ... not turned on or connected to AC power Follow these instructions to remove the system cover 1 Loosen and remove the thumbscrew securing the back cover 2 Push down the indentation located at the side of the back chassis 3 Slide the cover horizontally to the back and remove the cover in the direction of the arrow 2 3 3 1 4 ...

Page 27: ...d Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the fan duct 2 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats ...

Page 28: ...ons unless you are a qualified service technician 3 3 1 Follow these instructions to install the CPU 1 Align and install the processor on the carrier NOTE Apply thermal compound evenly on the top of the CPU Remove the protective cover from the underside of the heat sink 2 Carefully flip the heatsink Then install the carrier assembly on the bottom of the heatsink and make sure the gold arrow is loc...

Page 29: ... 29 Hardware Installation 5 1 3 2 4 6 4 3 ...

Page 30: ...ed and chips be used Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to insert the memory switch the direction CPU1 CPU0 DIMM_P0_B0 DIMM_P0_B1 DIMM_P0_A0 DIMM_P0_A1 DIMM_P0_D0 DIMM_P0_D1 DIMM_P0_C0 DIMM_...

Page 31: ... the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 Type Ranks Per DIMM and Data Width DIMM Capacity GB Speed MT s Voltage V Slots per Channel SPC and DIMM per Channel DPC 1DPC 2DPC 8Gb 16Gb 1 2V 1 2V RDIMM SRx8 8GB 16GB 3200 3200 RDIMM SRx4 16GB 32GB RDIMM DRx8 16GB 32GB RDIMM DRx4 32GB 64GB RDIMM 3DS 4R 8R x4 2H 64GB 4H 128GB 2H ...

Page 32: ... H1 H0 E1 E0 F1 F0 V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V V NOTE l There should be at least one DDR4 DIMM per socket l If only one DIMM is populated in a channel then populate it in the slot furthest away from CPU of that channel l Channel 0 s on each memory controller A E C G I M K O must be populated with same total capacity per channel if...

Page 33: ...lot 0 e g if RDIMM is installed into DIMM slot A0 the DCPMM must be installed into DIMM slot A1 CPU1 CPU0 F0 RDIMM Slot F1 Intel Optane DCPMM Slot E0 RDIMM Slot E1 Intel Optane DCPMM Slot H0 RDIMM Slot H1 Intel Optane DCPMM Slot G0 RDIMM Slot G1 Intel Optane DCPMM Slot K1 Intel Optane DCPMM Slot K0 RDIMM Slot L1 Intel Optane DCPMM Slot L0 RDIMM Slot I1 RIntel Optane DCPMM Slot I0 IRDIMM Slot J1 In...

Page 34: ...ly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Remove the thumbscrew on the back coverRemove the securing special screw on the riser bracket 2 Remove the thumbscrew on the riser bracket 3 Lift up the riser bracket out of system 4 Loosen and remove the bracket securing screw 5 Orient ...

Page 35: ... Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install a 3 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the HDD tray 4 Align the hard disk drive with the positioning stud on the HDD tray 5 Slide the hard disk drive into the HDD tray 6 Reinsert the HDD tr...

Page 36: ...ton 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the HDD tray 4 Align the hard disk drive with the positioning screw on the HDD tray 5 Secure the hard disk drive with five screws 6 Reinsert the HDD tray into the slot and close the locking lever Press Pull 2 3 1 4 5 ...

Page 37: ...7 Replacing the FAN Assemblly Follow these instructions to replace the fan assembly 1 Pull outward the fan ear 2 Lift up the fan assembly from the chassis 3 Reverse the previous steps to install the replacement fan assembly 1 2 3 ...

Page 38: ...ip on the right side of the power supply along the direction of the arrow At the same time pull out the power supply by using its handle 2 Insert the replacement power supply firmly into the chassis Connect the AC power cord to the replacement power supply 3 1 2 Before you remove or install the system cover Make sure the system is not turned on or connected to AC power ...

Page 39: ... 39 Hardware Installation 3 9 Cable Routing SSATA0 SL_SAS2 On board SATA Cable SSATA0 SATA0 SL_SAS1 Onboard SATA Cable SATA0 ...

Page 40: ...Hardware Installation 40 SATA1 SL_SAS0 On board SATA Cable SATA1 Onboard SATA Cable SATA4 SATA5 ...

Page 41: ... 41 Hardware Installation NVMe Cable USB Cable ...

Page 42: ...Hardware Installation 42 B P Cable F P Cable ...

Page 43: ... 43 Hardware Installation HDD BP Power HDD BP Signal ...

Page 44: ...Hardware Installation 44 This page intentionally left blank ...

Page 45: ..._P1_N1 DIMM_P1_P0 DIMM_P1_P1 DIMM_P1_O0 DIMM_P1_O1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 24 25 26 27 28 30 29 31 32 33 35 34 22 23 Item Description 1 HDD Back Plane Board Connector 2 SlimLine SAS Connector U2_P0_0 PCIe Gen4 3 SlimLine SAS Connector U2_P0_1 PCIe Gen4 4 Front Panel USB 3 0 Connector 5 Front Panel Connector 6 IPMB Connector 7 2 x 4 GPU Card Power Connector P12V_GPU2 8...

Page 46: ...ule Connector 23 TPM Module Connector SPI Interface 24 OCP Mezzanine Connector OCP 2 0 Gen3 x8 25 Riser Connector 2 SLOT2 PCIe Gen4 x32 Slot 26 Riser Connector 3 SLOT3 PCIe Gen4 x16 Slot 27 Power Supply Connector 1 Primary 28 Power Supply Connector 2 Secondary 29 2 x 3 Pin Rear HDD Back Plane Board 30 2 x 7 Pin HDD Back Plane Board Power Connector 31 2 x 2 Pin Backup Power Connector 12V_BP1 32 2 x...

Page 47: ..._N1 DIMM_P1_P0 DIMM_P1_P1 DIMM_P1_O0 DIMM_P1_O1 Clear CMOS CLR_CMOS Enable Default 1 2 3 21 3 21 3 NCSI Switch Onboard LAN OCP 2 0 Mezzanine OCP 3 0 Mezzanine SW1 OFF SW2 OFF ON ON OFF ON 1 2 ON Clear supervisor password BIOS recovery mode Force ME update ME_UPDATE BIOS_PWD ON ME recovery mode Normal Default Normal Default Normal Default Normal Default OFF BIOS_RCVR ME_RCVR J2 1 2 3 4 ON CPLD debu...

Page 48: ... Connector U_2_11 13 SlimLine SAS Connector U_2_12 14 SlimLine SAS Connector U_2_13 15 SlimLine SAS Connector U_2_14 16 SlimLine SAS Connector U_2_15 17 SlimLine SAS Connector U_2_16 18 SlimLine SAS Connector U_2_17 19 SlimLine SAS Connector U_2_18 20 SlimLine SAS Connector U_2_19 21 SlimLine SAS Connector U_2_20 22 SlimLine SAS Connector U_2_21 23 SlimLine SAS Connector U_2_22 24 SlimLine SAS Con...

Page 49: ...ption 1 SlimLine SAS Connector U_2_0 2 SlimLine SAS Connector U_2_1 3 SlimLine SAS Connector SL_SAS0 2 3 1 Item Description 28 SlimLine SAS Connector SL_SAS3 29 SlimLine SAS Connector SL_SAS4 30 SlimLine SAS Connector SL_SAS5 4 3 2 CBP2022 ...

Page 50: ...Hardware Installation 50 This page intentionally left blank ...

Page 51: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Page 52: ... Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This setup page provides items for configuration of the boot sequence Save Exit Save all the changes made...

Page 53: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Page 54: ...nd String Max CPU Speed CPU Signature Processor Core Microcode Patch Displays the technical information for the installed processor s Platform Information Processor PCH RC Revision Displays the platform information of the installed processor s and PCH Memory Information Total Memory Note2 Displays the total memory size of the installed memory Usable Memory Note2 Displays the usable memory size of ...

Page 55: ...ion LAN2 MAC Address Note3 Displays LAN MAC address information System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note2 This section will display capacity and frequency information of the memory that the customer has installed Note3 The number of LAN ports listed will depend on the motherboard system model...

Page 56: ...Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default ...

Page 57: ... Description Configuration Security Device Support Enable Disable BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable ...

Page 58: ...tings Press Enter to configure advanced items Please note that this item is configurable when COM1 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 VT UTF8 ANSI Default setting is VT100 Bits per second Selects the transfer rate for console redirection Options available 9600 19200 38400 57600 115200 Default ...

Page 59: ...t setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT UTF8 Combo...

Page 60: ... Management Windows Emergency Management Services EMS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item is...

Page 61: ...data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Page 62: ...to Enabled allows you to configure the serial port settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default setting is Enabled Current Displays the serial port base I O address and IRQ Possible Configures the serial port base I O address and IRQ Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 4 DMA IO 2F8h IRQ 4 DMA IO 3E8h IRQ 4 D...

Page 63: ...board LAN1 LAN2 I O ROM Note2 Enable Disable the onboard LAN1 LAN2 devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings Above 4G Decoding Enable Disable memory mapped I O to 4GB or greater address space Above 4G Decoding Options available Enabled Disabled Default setting is Enabled SR IOV Support If the system has SR...

Page 64: ...nd off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled Port 60 64 Emulation Enables the I O port 60h 64h emulation support This should be enabled for the complete USB Keyboard Legacy support for non USB aware OS Options availabl...

Page 65: ...ions available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Wait time in seconds to press ESC key to abort the PXE boot Press the keys to increase o...

Page 66: ...Post Report Configuration Parameter Description Post Report Configuration Error Message Report Post Error Message Enable Disable the POST Error Message support Options available Enabled Disabled Default setting is Enabled ...

Page 67: ...up 5 2 8 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system NVMe OPROM Select Options available BIOS Build In NVMe Device Default setting is BIOS Build In ...

Page 68: ...VGA Enable Disable 64bit capable devices to be decoded in Skip Above 4G Address VGA Space Options available Enabled Disabled Default setting is Disabled P2P Bridge IO Size Specifies P2P Bridge IO aligned to the size Options available 0x100 0x150 0x1000 Default setting is 0x1000 SATA HDD Security Frozen Enable Disable this item to send freeze lock command to SATA HHD Options available Enabled Disab...

Page 69: ...figuration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration Press Enter for configuration of advanced items ...

Page 70: ... items Attempt Priority Options available Host Attempt Redfish Attempt Default setting is Host Attempt Commit Changes and Exit Host iSCSI Configuration Press Enter to configure advanced items iSCSI Initiator Name Only IQN format is accepted Range from 4 to 223 Add an Attempt Delete Attempts Change Attempt Order ...

Page 71: ... 71 BIOS Setup 5 2 12 Intel R i350 Gigabit Network Connection ...

Page 72: ...he numeric keys to adjust desired values up to 15 seconds UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the Network Interface Control...

Page 73: ...ng VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Remove VLAN Press Enter to remove an existing VLAN ...

Page 74: ...BIOS Setup 74 5 2 14 Driver Health Parameter Description Driver Health Displays driver health status of the devices controllers if installed ...

Page 75: ...IOS Setup 5 3 Chipset Menu Chipset Setup menu displays submenu options for configuring the function of Platform Controller Hub PCH Select a submenu item then press Enter to access the related submenu screen ...

Page 76: ...BIOS Setup 76 5 3 1 Processor Configuration ...

Page 77: ...ble Default setting is Disable L2 RF0 Prefetch Disable Options available Enable Disable Default setting is Disable Adjacent Cache Prefetch When enabled cache lines are fetched in pairs When disabled only the required cache line is fetched Options available Enable Disable Default setting is Enable DCU Streamer Prefetcher Enable Disable DCU streamer prefetcher Options available Enable Disable Defaul...

Page 78: ...er Description Debug Consent Options available Enable Disable Default setting is Disable Total Memory Encryption TME Enable Disable total memory encryption TME Options available Enabled Disabled Default setting is Disabled ...

Page 79: ...k is the default allocation Options available 1G 4G 16G 64G 256G 1024G Default setting is 256G Isoc Mode Enable Disable the Isochronous support in order to meet the QoS requirements Quality of Service Options available Auto Enable Disable Default setting is Auto Numa Non Uniform Memory Access Enable Disable Non uniform Memory Access NUMA support to improve the system performance Options available ...

Page 80: ...s available 9 6GT s 10 4GT s 11 2GT s Auto Default setting is Auto SNC Sub NUMA Enable Disable Sub NUMA Cluster function Options available Disable Enable SNC2 2 clusters Default setting is Disable Stale AtoS Enable Disable Stale A to S directory optimization Options available Disable Enable Auto Default setting is Auto LLC dead line alloc Enable Disable fill dead lines in LLC Options available Dis...

Page 81: ...ng is Auto Enable ADR Enables the detecting and enabling of ADR Asynchronous DRAM Refresh function Options available Enable Disable Default setting is Enable Legacy ADR Mode Enable Disable the Legacy ADR Mode Options available Enable Disable Default setting is Disable Minimum System Memory Size Configures the minimum memory size Options available 2GB 4GB 6GB 8GB Default setting is 2GB ADR Data Sav...

Page 82: ...pe Displays the RAS type New SDDC Mode Enable Disable 48B SDDC ECC from ICX C0 Onwards Options available Disabled Enabled Default setting is Enabled Mirror Mode Mirror Mode will set entire 1LM memory in system to be mirrored consequently reducing the memory capacity by half Enables the Mirror Mode will disable the XPT Prefetch Options available Disabled Full Mirror Mode Partial Mirror Mode Default...

Page 83: ... decrease the desired values Leaky bucket high bit Configures leaky bucket high bit 1 63 Press the keys to increase or decrease the desired values ADDDC Sparing Enable Disable ADDDC Sparing Options available Disabled Enabled Default setting is Disabled Column Correction Disable Options available Disable Enable Default setting is Disable Set PMem Die Sparing Options available Disabled Enabled Defau...

Page 84: ... only to Chipset PCIe Root Ports Bridges Disable Programs ACS to all PCIe bridges Default setting is Enable DMA Control Opt In Flag Enable Disable DMA_CTRL_PLATFORM_OPT_IN_FLAG in DMAR table in ACPI Not compatible with Direct Device Assignment DDA Options available Enable Disable Default setting is Disable Interrupt Remapping Enable Disable the interrupt remapping support function Options availabl...

Page 85: ...guration Enable Disable Intel VMD technology Options available Enable Disable Default setting is Disable Intel VMD for Non Hotplug NVMe Note Enable Disable Intel VMD for Non Hotplug NVMe Options available Enable Disable Default setting is Disable Note This item appears when Intel VMD Configuration is set to Enable ...

Page 86: ...able Activate SST BF Enable Disable SST BF Options available Enable Disable Default setting is Disable Configure SST BF Note Enable Disable BIOS to configure SST BF High Priority Cores Options available Enable Disable Default setting is Enable Turbo Mode When this item is enabled the processor will automatically ramp up the clock speed of 1 2 of its processing cores to improve its performance When...

Page 87: ... CPU C6 ACPI C3 report to OS Options available Disable Enable Auto Default setting is Disable Enhanced Halt State C1E Core C1E auto promotion control Takes effect after reboot Options available Enable Disable Default setting is Disable Package C State Control Press Enter to configure advanced items Package C State Configures the state for the C State package limit Options available C0 C1 state C2 ...

Page 88: ...abled and cannot be access the RAID setup utility at boot time RAID Mode When set to RAID the SATA controller enables both its RAID and AHCI functions You will be allowed to access the RAID setup utility at boot time Options available AHCI RAID Default setting is AHCI Alternate Device ID on RAID Note 1 Enable Disable Alternate Device ID on RAID mode Options available Enable Disable Default setting...

Page 89: ...utility at boot time RAID Mode When set to RAID the SATA controller enables both its RAID and AHCI functions You will be allowed to access the RAID setup utility at boot time Options available AHCI RAID Default setting is AHCI Alternate Device ID on RAID Note 1 Enable Disable Alternate Device ID on RAID mode Options available Enable Disable Default setting is Disabled sSATA Port 0 1 2 3 4 5 The ca...

Page 90: ... 8 Miscellaneous Configuration Parameter Description Miscellaneous Configuration Active Video Selects the active video type Options available Auto Onboard Device PCIE Device Specific PCIE Device Default setting is Auto ...

Page 91: ...plays ME Firmware status information Current State Displays ME Firmware current status information Error Code Displays ME Firmware status error code Recovery Cause Displays ME Firmware recovery cause PTT Support Displays if the system supports the Intel Platform Trust Technology Suppress PTT Commands Displays if the system supports to Bypass TPM2 commands submitting to PTT Firmware ...

Page 92: ...nfigure advanced items WHEA Windows Hardware Error Architecture Support Enable Disable WHEA Support Options available Enable Disable Default setting is Enable Memory Error Enabling Press Enter to configure advanced items Memory Error Enable Disable Memory Error Options available Enable Disable Default setting is Enable Memory Corrected Error Enable Disable Memory Corrected Error Options available ...

Page 93: ... 93 BIOS Setup Parameter Description PCIe Error Enabling Press Enter to configure advanced items PCIE Error Enable Disable PCIE error Options available Enable Disable Default setting is Enable ...

Page 94: ...mp up the clock speed of 1 2 of its processing cores to improve its performance When this item is disabled the processor will not overclock any of its core Options available Enabled Disabled Default setting is Enabled CPU C6 report Enable Disable the BIOS to enable the report from the CPU C6 state ACPI C3 to the OS Options available Disabled Enabled Auto Default setting is Disabled Enhanced Halt S...

Page 95: ...s available Enabled Disabled Default setting is Enabled DCU Streamer Prefetcher Options available Enabled Disabled Default setting is Enabled Isoc Mode Enable Disable the Isochronous support in order to meet the QoS requirements Quality of Service Options available Auto Enabled Disabled Default setting is Auto Intel VT for Directed I O VT d Enable Disable the Intel VT for Directed I O VT d support...

Page 96: ...og Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note2 Configures OS Watchdog Timer The value is between 1 to 30 minutes Default setting is 10 minutes OS Wtd Timer Policy Note2 Configure OS Watchdog Timer Policy Options available Reset Do Nothing Power Down Power Cycle Default setting is Reset Wait BMC Ready POST...

Page 97: ...re advanced items View FRU Information Press Enter to view the FRU information BMC VLAN Configuration Press Enter to configure advanced items BMC network Configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Page 98: ...ose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Delete Oldest Record Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Opti...

Page 99: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Page 100: ...uration BMC VLAN ID Select to configure BMC VLAN ID The valid range is from 0 to 4094 When set to 0 BMC VLAN ID will be disabled BMC VLAN Priority Select to configure BMC VLAN Priority The valid range is from 0 to 7 When BMC VLAN ID is set to 0 BMC VLAN Priority will not be selected ...

Page 101: ...ailable Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information Real time get BMC networ...

Page 102: ...work during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Enable Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IP...

Page 103: ...all settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pre...

Page 104: ... the applications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually loa...

Page 105: ...ce Guard Ready Remove UEFI CA from DB Press Enter to remove Microsoft UEFI CA from Secure Boot DB Restore DB defaults Restore DB variable to factory defaults Secure Boot variable Displays the current status of the variables used for secure boot Platform Key PK Displays the current status of the Platform Key PK Press Enter to configure a new PK Options available Update Key Exchange Keys KEK Display...

Page 106: ...tabase Press Enter to configure a new DBT or load additional DBT from storage devices Options available Update Append OsRecovery Signatures Displays the current status of the OsRecovery Signature Database Press Enter to configure a new OsRecovery Signature or load additional OsRecovery Signature from storage devices Options available Update Append ...

Page 107: ...sired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Setup Flash Press Enter to run setup flash Dump full Setup Data Press Enter to dump full setup data to file Dump non default Setup Data Press Enter to dump non...

Page 108: ... the boot order priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Page 109: ... Discard Changes and Exit Discards changes made and exits the BIOS setup Options available Yes No Save Changes and Reset Restarts the system after saving the changes made Options available Yes No Discard Changes and Reset Restarts the system without saving any changes Options available Yes No Save Changes Saves changes done so far to any of the setup options Options available Yes No Discard Change...

Page 110: ...ese settings the system might not function properly Options available Yes No Save as User Defaults Saves the changes made as the user default settings Options available Yes No Restore User Defaults Loads the user default settings for all BIOS setup parameters Options available Yes No Boot Override Press Enter to configure the device as the boot up drive Launch EFI Shell from filesystem device Atte...

Page 111: ... Recovery failed 4 S3 Resume failed 7 Reset PPI is not available of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met 5 8 BIOS POST Beep code AMI standard 5 8 1 PEI Beep Co...

Page 112: ...BIOS Setup 112 This page intentionally left blank ...

Reviews: