background image

Technical and Operational Description

Replace Battery

1. Power turn off

2. Take the cover away

3. Take the battery away

4. Take new battery

5. Put new battery in

6. Fix the battery cover

Note:

1. Read the instructions on your device before replace new battery.

2. PCR120/MFR120 can used Single-cell alkaline, nickel-cadmium (NiCd), or nickel-metal

hydride

   (NiMH) Battery

12

Summary of Contents for MFR120 Series

Page 1: ...March 2007 REGISTERED TO ISO 9001 2000 8F No 31 Lane 169 Kang Ning St Hsi Chih Taipei Hsien 221 Taiwan Phone 886 2 2695 4214 FAX 886 2 2695 4213 www gigatms com tw 1 ...

Page 2: ...ubject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of GIGA TMS INC Rev Number Date Notes REVISIONS 01 March 07 Initial Release 2 ...

Page 3: ...ction against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case the use...

Page 4: ...Keep battery contact surfaces and battery compartment contacts clean by rubbing them with a clean pencil eraser or a rough cloth each time you replace batteries 6 Keep batteries away from children If swallowed contact a physician at once 7 Don t recharge a battery unless it is specifically marked rechargeable Attempts to recharge an alkaline battery may cause an imbalance within the cell leading t...

Page 5: ...contact surfaces and battery compartment contacts clean by rubbing them with a clean pencil eraser or a rough cloth each time you replace batteries 6 Keep batteries away from children If swallowed contact a physician at once 7 Don t recharge a battery unless it is specifically marked rechargeable Attempts to recharge an alkaline battery may cause an imbalance within the cell leading to gassing and...

Page 6: ...in unit PCR120 MFR120 RS232 Cable WAS T0017 LR03 AAA ALKALINE 1 5V Battery BAT T0010 Chain Sling TM09F1001 USB Cable for PCR120U MFR120U series WAS 1571 CD ROM RS232 Cable for PCR120 MFR120 series WAS T0017 Information 6 ...

Page 7: ...bad memory or incorrectly encoded data and so on the device will turn on the ERROR indicator RFID Card Scan Area Scan the RFID card to reader Technical and Operational Description Battery Box Put the battery in box and hold battery Connector For connection to host computer and external Power Operate Keypad Turn the PCR120 MFR120 on off power and Operate Operation LED Indicator LCD Main Screen Chai...

Page 8: ...ubmenu 1 Corresponding Key Power Exit Back Cancel No Key Function 2 Corresponding Key 3 Corresponding Key 4 Corresponding Key Up Up scroll Decrease Scan Key Function Down Down scroll Increase Event Key Function Menu Enter Save Next Yes Key Function Technical And Operational Description LCD Display Display Date Week Time Menu Item Record Data Parameter Setting Other Information EM Buzzer ON Event M...

Page 9: ...t ON Reset Default BackLight 15 seconds Auto Power Off 30 seconds Power Mode Switch Mode Sound ON 3 1 Status 3 2 View Display Memory Status Used Space Unused Space Total Space Display all records in memory 4 1 Date Format 4 2 Set Date Time Set Date Format Select Year Month Date Date Month Year Month Date Year Default Month Date Year Set Date Year Month Date Set Time Week Hour Minute Second 5 1 Pro...

Page 10: ...ready is full After scan card LCD Display message Check RTC Check FLASH Decode Error No Record Record not empty ISP MODE FLASH Full Counterplot Set Date and Time Contect Agent Scah Card again or Change Card Swipe Card Download Records and Erase Records Update New Firmware Download Records and Erase Records Status Power On Ready Read OK Read Error Green LED Take turns blink 2 times Off Blink 1 time...

Page 11: ... and you must do the RTC time setting before you use the unit When the device is powered by battery it would have Low Battery Detect function When the battery goes low the LCD would display and you must change battery immediately otherwise the unit would shut down any time without pre warning 5 Scan RFID Card 6 Operate for Calendar 7 Memory Full Warning Log database memory is full You are not able...

Page 12: ...the cover away 3 Take the battery away 4 Take new battery 5 Put new battery in 6 Fix the battery cover Note 1 Read the instructions on your device before replace new battery 2 PCR120 MFR120 can used Single cell alkaline nickel cadmium NiCd or nickel metal hydride NiMH Battery 12 ...

Page 13: ...er DC 5V PCR120 MFR120 DSUB 9P POWER JACK No use Note 1 When PCR120 MFR120 is connected disconnected with an external power adapter it would be turned On Off automatically 2 When PCR120 MFR120 is not connected with an external power adaptor the corresponding key for power on PCR120 MFR120 needs to be pressed all the time during the communications with the PC 13 ...

Page 14: ... USB interface cable 1 1 Connections Note 1 When PCR120 MFR120 is connected disconnected with USB port it would be turned On Off automatically USB 4P FEMALE PIN 1 3 2 4 FUNCTION VCC D D GND MINI USB 4P 1 3 2 4 FUNCTION RXD TXD VCC GND PCR120 MFR120 14 ...

Page 15: ...racters 20h 3 TIME is 24hrs YYYY MM DD HH MM SS W SP WEEK SUN MON TUE WED THU FRI SAT 0 1 2 3 4 5 6 STX CARD TYPE WEEK CARD ID FC CR A MM DD YYYY HH MM SS W SP DD MM YYYY HH MM SS W SP SP WEEK CARD TPYE 8 or 16 CARD ID CARD TYPE Mifare 1k Mifare 4k Mifare Ultrlight Mifare DESFire EM 125K Felica 1 2 3 4 5 6 EVENT CODE 0 1 2 3 4 5 6 7 8 9 EVENT EVENT USER DEFINE EVENT 15 ...

Page 16: ...GNET VER 1 2 Communication Protocol Version 1 2 GNET V1 2 Memory Size for Storing Data RTC CLOCK CMOS Serial Flash Memory 512K bytes Up to 8192 records 32 Bytes Record Real Time Clock RTC module and back up capacitor USB Interface Full compliance with the USB Specification V 1 1 The device uses a Virtual Serial Port Driver making it appear to have the software like a standard RS232 Serial Port USB...

Page 17: ...3 NACK Handshaking STX CMD CONTENTS CR PACKET STX CMD CONTENTS CHKSUM CR 2 B Start of Text 02 STX REPLY CONTENTS CR ITEM Dec Control Key Function Hex 13 M Carriage Return 0d ASCII ASCII Command Code ASCII ASCII ASCII Contents Data ASCII ASCII ASCII Check Sum ASCII REPLY 78 65 N A Negative Acknowledge 4e 41 17 ...

Page 18: ... Set Password Logout Erase All Record J I Get Machine ID Set Machine ID D I Access Denied Invalid Command or Data F E Command Execution Failed Database is Empty PCR120 MFR120 Terminal has an extensive list of Commands that allow manipulating its internal database setting functional parameters and getting data on its current status There are 2 levels of access to the PCR120 MFR120 User and Supervis...

Page 19: ...0d EXAMPLE PASSWORD PASSWORD 4 Characters for Login 0000 Initial value 0000 LOGOUT STX O CR STX A CR 02 O 0d Logout 02 A 0d EXAMPLE SET PASSWORD STX P CR STX A or D or I CR PASSWORD PASSWORD New four characters password 02 D 0d Login password command is not executed 02 I 0d Invalid password Access Security Commands 19 ...

Page 20: ... Width 0000h 0800h READ RECORD BY NUMBER STX G CR STX A CR 02 G 0d Record data ABCDEF 02 A 0d EXAMPLE DATA 20h DATA 20h Record Data ABCDEF DATE TIME DATA TIME DATE TIME 11 10 2004 10 39 23 20 STX E or D or F CR 02 E 0d Database is empty 02 P 0d Set new password 1234 02 A 0d EXAMPLE 1234 02 D 0d Set new password is not executed Invalid password 02 I 0d 20 ...

Page 21: ... is not executed RECOVERY ALL DATABASE READOUT TRANSACTION STX M CR STX A or I CR 02 R 0d 02 A 0d EXAMPLE Database is recovery 02 I 0d Invalid command 02 E 0d Erase all records 02 A 0d EXAMPLE 02 D 0d Erase command is not executed Communication Protocol ERASE ALL RECORD STX E CR STX A or D CR Erase Duration 60 seconds 21 ...

Page 22: ...l number ROM T0571 Firmware version 1 03 Modify times 0 02 A 0d V1 03R0 EXAMPLE ROM T0571 SET DATE AND TIME STX S CR STX A or I or D CR 02 S 0d Set Date 2000 5 5 Set Time 12 30 00 Saturday 02 A 0d YYYYMMDDhhmmss 200005051230006 EXAMPLE YYYY MM DD hh mm ss Year 2000 20xx Month 01 12 Date 01 31 Hour 00 23 Minute 00 59 Second 00 59 Invalid Date Time 02 I 0d Set Date Time is not executed 02 D 0d 22 ...

Page 23: ... 02 A 0d EXAMPLE Get Time 14 20 31 Thursday YYYYMMDDhhmmss 20001108142031 Get Date Time is not set or invalid 02 F 0d SET MACHINE ID STX J CR STX A or I or D CR 02 J 0d Set Machine ID 00 02 A 0d EXAMPLE 00 255 00 Invalid command or data 02 I 0d 02 D 0d Set Machine ID is not executed 23 ...

Page 24: ...ARE MANAGEMENT MODE STX X CR STX A CR 02 X 0d Enter firmware management mode 02 A 0d EXAMPLE 02 I 0d Get Machine ID 00 02 A 0d EXAMPLE 00 Get Identification is not set or otherwise invalid 02 F 0d GET MACHINE STX I CR STX A CR 00 255 24 ...

Page 25: ...FFh 0 255 second 00h Off FFh On 00h mm dd yyyy FFh yyyy mm dd other dd mm yyyy 00h Tracks Parallel 01h Credit Card Mode other Tracks Series 0 1h only 0 event 2h 0 1 event nh 0 n 1 event Max n 10 10 FFh 0 9 event 16 Characters Password 30 1FBh 1FC 1FFh 4 Characters GET REGISTER STX B CR STX A CR REGISTER REGSTER PARAM CHKSUM PARAM Register Address 2 Bytes Width 00h FFh Set Parameters of Register SE...

Reviews: