Code
Operation
Example
Notes
OPTC (d)
output temp cal pmtr
(This command is used for diagnostic purposes only.)
OR (d)
output power level
OR
Send the output power level.
OS (2b)
output status bytes
(This command is not supported.)
PL d t
power level
PL-5.1DM
Set the output level to -5.1 dBm.
PM 0
PM off
PM0
Deactivate pulse modulation.
PM 1
PM ext + on
PM1
Activate pulse modulation, external pulse
positive true.
PM 2
PM int on
PM2
Activate internal pulse modulation.
PM 3
PM ext - on
PM3
Activate pulse modulation, external pulse
negative true.
PM 4
PM trig + on
PM4
Activate pulse modulation, external
rising edge trigger.
PM 5
PM trig - on
PM5
Activate pulse modulation, external falling
edge trigger.
PR d t
PM int rate
PR50KZ
Activate internal pulse modulation; set the
rate to 50 kHz.
PW d t
PM int width
PW1US
Activate internal pulse modulation; set the
width to 1
µ
s.
PY d t
PM int delay
PY.1US
Activate internal pulse modulation; set the
delay to .1
µ
s.
RC n
recall front panel setup
RC6
Recall the front panel setup stored at
memory location 6.
RF 0
RF off
RF0
Deactivate/activate the RF output.
RF 1
RF on
RF1
RFD0
RF ON @ Freq Cng off
RFD0
Deactivate/activate Special Function 21 (RF
on at frequency change); this function causes
the RF output to remain on during frequency
changes (band changes and filter changes
excepted).
RFD1
RF ON @ Freq Cng on
RFD1
SB h
set bit
This command is used for diagnostic purposes only
SC0
scan off
SC0
Deactivate scan modulation or variable
attenuation (Opt. 27).
SC1
scan ext on
SC1
Activate external scan modulation (Opt. 27).
SC2
scan sine on
SC2
Activate internal scan modulation (Opts. 24
& 27), with a sine wave.
SC3
scan square on
SC3
Activate internal scan modulation (Opts. 24
& 27), with a square wave.
SC4
scan triangle on
SC4
Activate internal scan modulation (Opts. 24
& 27), with a triangle wave.
SC5
variable attenuation on
SC5
Activate variable attenuation
(Opt. 27).
SD d t
internal scan modulation or variable
attenuation depth
SD-20DB
Set depth for scan modulation or variable
attenuation (Opt. 27) to
-20 dBm.
SF d t
freq resolution increment
SF1KZ
Set the CW frequency resolution to 1 kHz.
SHA1
unleveled
SHA1
Select the unleveled mode (disable automatic
level control).
SHCW d t
CW resolution increment
SHCW1KZ
Set the CW frequency resolution to 1 kHz.
SHM4 d t
self test
SHM410MZ
Run the instrument self test program in
10 MHz steps and display the results.
SHM5
turn off diagnostics
This command is not supported
SHPL d t
set power level step
SHPL3DB
Set the level resolution to 3 dB.
SHPM
8757A mode (ext PM on)
SHPM
Activate external PM (for use with Model
8757A).
SHPS d t
uncouple attenuator & ALC; set
attenuator in 10 dB increments
SHPS40DB
Uncouple the attenuator from the level
control system; set the attenuator to 40 dB.
Model GT 9000 Microwave Signal Generator
2-22
Manual No. 120AM00250, Rev C, September 1998
Summary of Contents for GT 9000
Page 12: ...Series GT 9000 Microwave Synthesizers x Manual No 120AM00250 Rev C September 1998 ...
Page 14: ...Series GT 9000 Microwave Synthesizers xii Manual No 120AM00250 Rev C September 1998 ...
Page 18: ...Series GT 9000 Microwave Synthesizers xvi Manual No 120AM00250 Rev C September 1998 ...
Page 20: ...Series GT 9000 Microwave Synthesizers xviii Manual No 120AM00250 Rev C September 1998 ...
Page 94: ...Model GT 9000 Microwave Synthesizer 3 36 Manual No 120AM00250 Rev C September 1998 ...
Page 122: ...Model GT 9000 Microwave Synthesizer 4 28 Manual No 120AM00250 Rev C September 1998 ...
Page 142: ...Model GT 9000 Microwave Synthesizer 5 16 Manual No 120AM00250 Rev C September 1998 ...
Page 198: ...Model GT 9000 Microwave Synthesizer 6 56 Manual No 120AM00250 Rev C September 1998 ...
Page 206: ...Model GT 9000 Microwave Synthesizers 7 2 Manual No 120AM00250 Rev C September 1998 ...
Page 232: ...Model GT 9000 Microwave Synthesizer A 26 Manual No 120AM00250 Rev C September 1998 ...
Page 238: ...Model GT 9000 Microwave Synthesizer Index 6 Manual No 120AM00250 Rev C September 1998 ...