2 - DATA OF APPLIANCES

3 - TECHNICAL DATA

The instructions contained in this manual apply to our gas
cookers in the II2H3+ category (see table on page 8). 
The data plate is located on the front of the appliance and

on the control panel. It contains all necessary reference
data such as the name of the manufacturer, input pressu-
re, gas type setting, etc.

0051

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

G30/G31

28/37 mbar

G20

20 mbar

N. 

51BQ2900

51BQ2900

51BQ2900

51BQ2900

51BQ2901

51BQ2901

Model

KCP4

KCP82

OPCP4

OPCP82

CCPG4

CCPG82

External dimensions

(LxPxH+H1) - mm

400 x 900 x 875-1090

800 x 900 x 875-1090

400 x 900 x 530

800 x 900 x 530

400 x 700 x 875-1090

800 x 700 x 875-1090

Plumbing

connection - mm

Ø 12

Ø 12

Ø 12

Ø 12

Ø 12

Ø 12

Water 

outlet

R 1"

R 1"

R 1"

R 1"

R 1"

R 1"

Gas connection

R 3/4" ISO R228

R 3/4" ISO R228

R 3/4" ISO R228

R 3/4" ISO R228

R 1/2" ISO R228

R 1/2" ISO R228

Tank 

capacity (lt)

36

2 x 36

36

2 x 36

28

2 x 28

Summary of Contents for CCPG4

Page 1: ...013_03 Installation operating and maintenance instructions 12 2005 GAS PASTA COOKER KCP4 KCP82 OPCP4 OPCP82 CCPG4 CCPG82 COPYRIGHT 2004 GIGA GRANDI CUCINE SRL ...

Page 2: ...ctions 11 Note for the installer 11 Running the appliance on other types of gas 11 Replacing the main burner nozzle 11 Pilot burner nozzle 11 Adjusting the low flame 11 Maintenance page 11 Replacing parts 12 Ignition plung 12 Gas tap 12 Thermocouple 12 Using the appliance 13 First time use of the appliance 13 Ignition 13 Turning the pilot burner on 13 Turning the main burner on and adjusting the t...

Page 3: ...ge tap Inlet tap Gas control knob Piezo electric lighter Water outlet Water inlet Gas connection A B C D E F G C B D A G 21 21 220 F E 220 410 310 G 100 100 F E 250 KCP4 weight approx 100 kg G 21 21 220 F E 220 410 310 G 100 100 F E 250 C B D A ...

Page 4: ...00 A F G C B D A KCP82 G 21 21 220 F E 220 410 310 G 100 100 F E 250 A C D C B D weight approx 112 kg Drainage tap Inlet tap Gas control knob Piezo electric lighter Water outlet Water inlet Gas connection A B C D E F G OPCP4 weight approx 70 kg ...

Page 5: ...as pasta cooker 5 Dimensions A C D C B D 900 C B D A 800 900 A F G Drainage tap Inlet tap Gas control knob Piezo electric lighter Water outlet Water inlet Gas connection A B C D E F G OPCP82 weight approx 96 kg ...

Page 6: ...0 310 250 G G 21 21 220 285 100 100 F F E E 220 310 250 D B C A G G 21 21 220 285 100 100 F F E E 220 310 250 A CCPG82 D B C D B C weight approx 96 kg weight approx 112 kg Drainage tap Inlet tap Gas control knob Piezo electric lighter Water outlet Water inlet Gas connection A B C D E F G ...

Page 7: ...LU EE LV LT EE LV LT NO MT CY IS HU CY MOD MOD ART N N Qn kW m3 h MADE IN ITALY Predisposto a gas Gas preset Prevu pour gaz Eingestelt für Gas Preparado para gas Geschuckt voor V AC kW Hz THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE AND INSTALLED IN A WELL VENTILATED ROOM READ THE INSTRUCTION MANUALS BEFORE INSTALLING AND USING THE APPLIANCE THE APPLIANCE MUST BE INSTALLED ...

Page 8: ... G31 HuB 9 45 kWh m3 m3 h HuB 12 87 kWh kg kg h Nominal capacity Low flame Nominal capacity Low flame G20 G30 31 20 mbar 28 37 mbar II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 15 15 245 adjustable 160 100 adjustable 20 21 10 5 4 1 4 4 2 x 245 adjustable 2 x 160 2 x 100 adjustable 20 42 10 5x2 21 0 4 1x2 8 2 22 20 2 x 230 adjustable 2 x 150 2 x 100 adjustable 20 36 9x2 18 0 3 8x2 7 6 ...

Page 9: ...ical requisites During assembly the following legal and technical re quisites should be adhered to relevant national legislation local building and fire safety regulations worksheet Technical rules for installing gas worksheet Technical rules for LP gas worksheet Gas installations in industrial kitchens industrial injury legislation local Gas Board regulations current CEI regulations INSTALLATION ...

Page 10: ...as Flow Regulation table If you wish to check the nominal capacity further you may do so using a gas meter according to the so called volumetric method It is normally enough however simply to check that the nozzles are functioning correctly Checking input pressure Fig 3 Input pressure should be measured using a gauge e g a gooseneck pipe min resolution 0 1 mbar Remove screw 22 from the pressure so...

Page 11: ...as been transformed or adapted recheck its functions as described in paragraph Checking the functions Replacing the main burner nozzle To change nozzle 30 open the doors Unscrew the nozzle from the nozzle holder using a 12 spanner repla ce with a new nozzle see TECHNICAL DATA table If necessary to make changing the nozzle easier loo sen screws 39 to remove the air adjustment sleeve Pilot burner ad...

Page 12: ...ion lead loosen the lock nut and insert a new plug Gas tap Fig 3 Loosen the gas piping and thermocouple hoses then loosen the screws fixing the gas supply to the gas ramp and insert a new tap Thermocouple Figs 2 3 Loosen the screws fixing the thermocouple 38 to the gas 6 tap and the pilot burner 34 insert the new part After replacing the parts fit the control panel and its parts back in the right ...

Page 13: ...ob to the right until it is on high or else continue until it reaches low the heating capacity must be set between these two positions TURNING THE APPLIANCE OFF Turning the appliance off during normal operation To turn the main burner off only simply turn the knob to this way only the pilot burner will stay on To turn the appliance off completely turn the knob to this will turn the pilot burner of...

Page 14: ...de of fibrous synthetic material rubbing in the direction of the satin finish Rinse and dry thoroughly Never use wire wool for cleaning stainless steel or leave it in contact with the steel as very small ferrous deposits could remain on the surface and cause the formation of ru st by contamination Precautions during use Sauces and condiments all the stainless steel containers used for notoriously ...

Page 15: ...T TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSI BLE IF THE INSTRUCTIONS CONTAINED IN THIS MA NUAL ARE NOT OBSERVED GIGA GRANDI CUCINE S r l Via Pisana 336 Loc Olmo 50018 SCANDICCI FI ITALY Tel 39 055 722 33 11 linee r a Fax 39 055 7310 056 www gigagrandicucine it info gigagrandidicucine it ...

Reviews: