background image

R152-ZE0

AMD EPYC™ 7003 UP Server System - 1U Gen4 NVMe

User Manual

Rev. 1.0

Summary of Contents for E152-ZE0

Page 1: ...R152 ZE0 AMD EPYC 7003 UP Server System 1U Gen4 NVMe User Manual Rev 1 0 ...

Page 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Page 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Page 4: ...e risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is not suitable for use in locations where children are likely to be present WARNING This equipment is intended to be used in Restrict Acce...

Page 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully They...

Page 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Page 7: ...5 3 3 Installing the CPU and Heat Sink 26 3 4 Installing the Memory 28 3 4 1 Eight Channel Memory Configuration 28 3 4 2 Installing a Memory 29 3 4 3 Processor and Memory Module Matrix Table 29 3 4 4 Memory Population Table 30 3 5 Installing the PCI Expansion Card 31 3 6 Installing the GPU Card 32 3 7 Installing the Hard Disk Drive 33 3 8 Installing the Mezzanine Card 34 3 9 Replacing the Power Su...

Page 8: ...uration 76 5 2 19 MAC IPv4 Network Configuration 77 5 2 20 MAC IPv6 Network Configuration 78 5 3 AMD CBS Menu 79 5 3 1 CPU Common Options 80 5 3 2 DF Common Options 85 5 3 3 UMC Common Options 90 5 3 4 NBIO Common Options 104 5 3 5 FCH Common Options 110 5 3 6 NTB Common Options 114 5 3 7 SOC Miscellaneous Control 115 5 3 8 Workload Tuning 116 5 4 AMD PBS Menu 117 5 4 1 RAS 118 5 5 Chipset Setup M...

Page 9: ... 9 5 8 2 UEFI Application Boot Priorities 135 5 9 Save Exit Menu 136 5 10 BIOS POST Beep code AMI standard 137 5 10 1 PEI Beep Codes 137 5 10 2 DXE Beep Codes 137 ...

Page 10: ... 10 This page intentionally left blank ...

Page 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Page 12: ...t LAN 2 x 1Gb s LAN ports Intel I350 AM2 1 x 10 100 1000 management LAN Socket Socket Video Integrated in Aspeed AST2600 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp DDR4 SDRAM Socket Socket Storage 2 x 2 5 SATA SAS Gen4 NVMe hot swappable HDD SSD bays SAS card is required for SAS devices support 2 x M 2 slots on CMTP182 Riser Card M key PCIe Gen4 x4 per slot Supports NGFF...

Page 13: ...y NOTE 1 If using 280W CPU please select 1300W power supply 2 If using 250W double slot GPU or 2 x single slot 125W GPUs please select 1300W power supply Socket ocket System Management Aspeed AST2600 management controller GIGABYTE Management Console AMI MegaRAC SP X web interface Dashboard JAVA Based Serial Over LAN HTML5 KVM Sensor Monitor Voltage RPM Temperature CPU Status etc Sensor Reading His...

Page 14: ...idity Operating temperature 10 C to 35 C Non operating temperature 40 C to 60 C Operating humidity 8 80 non condensing Non operating humidity 20 95 non condensing NOTE Ambient temperature limited to 30 C if using 280W CPU Socket Socket System Dimension 1U 438mm W x 43 5mm H x 400mm D ...

Page 15: ...PCIe x16 FHFL slots support 1 x DW GPU or 2 x SW GPUs 1 x PCIe x16 LPHL slot Riser CRSE020 Riser CRSH01H PCIe4 0 x16 PCIe4 0 x16 1 x PCIe x16 LPHL slot Riser CRSH01E PCIe4 0 x16 PCIe2 0 x2 PCIe2 0 x1 USB2 0 x1 OCP 3 0 mezzanine Switch NCSI NCSI NCSI Intel i350 AM2 2 x 1G LAN Flash 512 MB TPM USB3 0 USB2 0 x2 2 x USB 3 0 AMD MILAN Zen3 Core Socket SP3 MUX MLAN RGMII 10 100 1G PHY USB2 0 x1 USB2 0 x...

Page 16: ...Hardware Installation 16 This page intentionally left blank ...

Page 17: ...Front Panel LEDs and Buttons 5 10 100 1000 Server management LAN port 6 GbE LAN Port x 2 7 Mini DP Port 8 Mezzanine Card Slot Option OCP V3 0 Card NOTE The Green HDD Latch Supports NVMe Please Go to Chapter 2 3 Front Panel LED and Buttons for detail description of function LEDs 2 2 Rear View No Description 1 GPU Card Slot 1 2 3 4 5 6 7 8 HDD 0 HDD 1 PSU 1 ...

Page 18: ...CPI S1 state sleep mode N A Off System is not powered on or in ACPI S5 state power off System is in ACPI S4 state hibernate mode 2 ID Button This LED represents the RoT function LED behavior Please see the following section for detail LED behavior 3 System Status LED This LED represents the RoT function LED behavior Please see the following section for detail LED behavior ...

Page 19: ...ion 1 1GbE Speed LED Yellow On 1Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring ...

Page 20: ...Hz Green Blinking Power supply firmware updating mode Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut down failure OCP OVP fan failure and UVP 1 Hz Amber Blinking Power supply warning events where the power supply continues to operate high temp high power high current and slow fan ...

Page 21: ...Back Panel Removed HDD Slot LED on Back Panel Disk LED Removed HDD Slot RAID SKU No RAID configuration via HBA RAID configuration via HW RAID Card or SW RAID Card HDD Access HDD Present No Access BLINK 2 BLINK 2 OFF OFF OFF OFF OFF OFF Low Speed 2 Hz 3 3 Rebuilding HDD Fault OFF OFF ON OFF ON OFF OFF OFF Locate Amber Green ON 1 ON OFF ON 1 OFF Green Amber Green ON 1 Green OFF Amber Amber OFF LED1 ...

Page 22: ...System Appearance 22 This page intentionally left blank ...

Page 23: ...u are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do...

Page 24: ...ed to AC power Follow these instructions to remove the rear system cover 1 Remove the screw on the top cover 2 Unlock the plastic handle and pull the grip handle to open the panel cover 3 Slide the cover to the rear of the system and then remove the cover in the direction indicated by the arrow 4 To reinstall the chassis cover reverse steps 1 3 2 1 4 3 ...

Page 25: ... and Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the fan duct 2 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats ...

Page 26: ...w these instructions to install the CPU 1 Align and install the processor on the carrier making sure to line up the triangle markers on the corner of the CPU to the triangle mark on the corner of the CPU carrier 2 Slide the carrier assembly into the channels of the carrier bracket 3 Close the carrier bracket so that it firmly latches on to the CPU socket 4 Close the CPU socket cover 5 Tighten and ...

Page 27: ...tallation CPU 4 5 6 1 3 2 7 2 3 1 4 8 9 3 1 2 4 When installing the heat sink over the CPU use T30 Lobe driver to tighten the 4 captive nuts in sequential order 1g2g3g4 The screw tightening torque 8 0 5kgf cm 17 0 1 0 lbf in ...

Page 28: ...h CPU DIMM_P0_A0 DIMM_P0_B0 DIMM_P0_C0 DIMM_P0_D0 DIMM_P0_H0 DIMM_P0_G0 DIMM_P0_F0 DIMM_P0_E0 Read the following guidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off the computer and unplug the power cord from the power outlet before installing the memory...

Page 29: ...y Follow these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 4 3 Processor and Memory Module Matrix Table Processor and Memory Module Matrix Table 1 DIMM CPU CPU0 2 DIMMs...

Page 30: ...n memory slot DIMM1 3 4 4 Memory Population Table DIMM Type DIMM Population Max EPYC 7003 DDR Frequency MHz DIMM 0 RDIMM 1R 1 Rank 3200 2R or 2DR 2 Ranks 3200 LRDIMM 4DR 4 Ranks 3200 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 EPYC Memory Speed based on DIMM Population One DIMM per Channel ...

Page 31: ...ult in personal injury or damage to equipment The PCI riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Remove the screws on the riser bracket 2 Lift up the riser bracket out of system 3 Remove the slot covers from the riser bracket 4 Orient the PCIe card with the riser guid...

Page 32: ... secure the GPU card in place 3 1 1 2 5 3 4 Before you install the GPU card l Voltages can be present within the server whenever an AC power source is connected This voltage is present even when the main power switch is in the off position Ensure that the system is powered down and all power sources have been disconnected from the server prior to installing a GPU card Make sure the system is not t...

Page 33: ...f inserted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install a 2 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever to remove the HDD tray 4 Align the hard disk drive with the positioning stub on the HDD tray 5 Slide hard disk drive into the blank HDD tray 6 Reinsert the HDD tray ...

Page 34: ...e instructions to install an OCP 3 0 Mezzanine card 1 Remove the screw securing the OCP 3 0 card slot cover 2 Remove the slot cover from the system 3 Insert the OCP 3 0 card into the card slot ensuring that the card is firmly connected to the connector on the motherboard 4 Tighten the thumbnail screw to secure the OCP 3 0 card in place 5 Reverse steps 3 4 to replace the OCP 3 0 card 1 2 3 ...

Page 35: ... the left side of the power supply unit along the direction of the arrow 2 Pull the power supply handle at the same time and pull out the power supply unit 3 Insert the replacement power supply unit firmly into the chassis Connect the AC power cord to the replacement power supply 4 Repeat steps 1 3 for replacement of the second power supply 1 3 2 ...

Page 36: ...System Hardware Installation 36 HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable 3 10 Cable Routing ...

Page 37: ... 37 System Hardware Installation PMBus Cable Power Distribution Board to Motherboard Power Cable ...

Page 38: ...System Hardware Installation 38 U 2 NMVe to HDD Back Plane Board Cable NMVe0 U 2 NMVe to HDD Back Plane Board Cable NMVe1 ...

Page 39: ... 39 System Hardware Installation On Board SATA to HDD Back Plane Board Cable GPU Card Power Cable Recommend 1 2 3 ...

Page 40: ...System Hardware Installation 40 This page intentionally left blank ...

Page 41: ... OCP 3 0 SFF Type Gen4 x16 2 Front panel USB 3 0 Connector 3 Proprietary PCIe Slot Z 1 Gen 4 x8 slot GENZ_1 4 Proprietary PCIe Slot Z 1 Gen 4 x8 slot GENZ_1 5 Front Panel Connector 6 System Fan Connectors 7 Proprietary PCIe Slot Z 2 Gen 4 x8 slot GENZ_2 8 Proprietary PCIe Slot Z 2 Gen 4 x8 slot GENZ_2 9 HDD Back Plane Board Connector 10 System Power Connector 11 System Fan Connectors ...

Page 42: ...SlimLine SAS Connector U2_0 NVMe Signal 14 PMBUS Connector 15 VGA Cable Connector 16 SlimLine SAS Connector SL_CN2 SATA Signal 17 BMC Firmware Readiness LED 18 System Battery Cable Connector 19 Proprietary PCIe Slot Z 5 Gen 4 x8 slot GENZ_5 20 Front Panel USB 3 0 Connector ...

Page 43: ... CMOS CLR_CMOS Enable Default 3 2 1 NCSI Switch Onboard LAN OCP 3 0 Mezzanine SW OFF ON ON 21 3 ON BIOS recovery mode Normal Default BIOS Defined BIOS Defined Clear supervisor password OFF HOST_SMBUS_SEL PMBUS_SEL BIOS_PWD BIOS_RCVR Normal Default J2 1 2 3 4 ...

Page 44: ...Motherboard Components 44 This page intentionally left blank ...

Page 45: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Page 46: ...f the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This...

Page 47: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Page 48: ... memory size of the installed memory Memory Frequency Note3 Displays the frequency information of the installed memory VR Information Version Displays VR version information AGESA PI Version PI Version Displays AGESA PI version information Onboard LAN Information LAN1 MAC Address Note1 Displays LAN MAC address information LAN2 MAC Address Note2 Displays LAN MAC address information System Date Sets...

Page 49: ... Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default ...

Page 50: ...BIOS Setup 50 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Page 51: ...ble BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Support Select Enable to activate TPM support feature Options available Enabled Disabled Default setting is Disabled ...

Page 52: ...BIOS Setup 52 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Page 53: ...OnBrd Ext VGA Select Note Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard Note This configurable option will be displayed when Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Page 54: ... 2 4 AST2600 Super IO Configuration Parameter Description AST2600 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration of advanced items ...

Page 55: ... Note1 Enable Disable the Serial Port COM When set to Enabled allows you to configure the Serial port 1 2 settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default setting is Enabled Devices Settings Note2 Displays the Serial Port 1 2 device settings ...

Page 56: ... IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Please note that t...

Page 57: ...tion Wake System from S5 Note1 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time enabled system will wake on the hr min sec specified Default setting is Disabled Note1 Advanced items prompt when this item is defined ...

Page 58: ...r LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is ANSI Bits per second Selects the transfer rate for console redirection Options...

Page 59: ... 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT U...

Page 60: ...MS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when Serial Port for Out of Band Mana...

Page 61: ...ta loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Page 62: ...le the CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is Enabled CPU 0 Information Press Enter to view more information related to CPU ...

Page 63: ... 45 BIOS Setup 5 2 8 PCI Subsystem Settings ...

Page 64: ...eed Options available Auto Maximum Gen1 Gen2 Gen3 Gen4 Default setting is Auto Onboard LAN Controller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note2 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings...

Page 65: ...ble Auto Enabled Disabled Default setting is Enabled XHCI Hand off Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled USB hardware delays and time outs USB transfer time out The time out val...

Page 66: ... 10 sec 20 sec 30 sec 40 sec Default setting is 20 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto ...

Page 67: ...ions available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Wait time in seconds to press ESC key to abort the PXE boot Press the keys to increase o...

Page 68: ...BIOS Setup 68 5 2 11 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system ...

Page 69: ... 45 BIOS Setup 5 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type ...

Page 70: ...POST LOGO Configuration Parameter Description UEFI Configuration Output Device Type Select output device Options available First loaded Device Onboard Device External Device Specific Device Default setting is Onboard Deviceevice ...

Page 71: ... 45 BIOS Setup 5 2 14 AMD Mem Configuration Status Parameter Description CPU0 Press Enter to view the memory configuration status related to CPU 0 ...

Page 72: ...iguration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration Press Enter for configuration of advanced items ...

Page 73: ...Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add Attempt Press Enter for configuration of advanced items Delete Attempt Press Enter for configuration of advanced items Change Attempt Order Press Enter for configuration of advanced items ...

Page 74: ...BIOS Setup 74 5 2 17 Intel R Ethernet Controller I350 ...

Page 75: ...ort by blinking the associated LED Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the ...

Page 76: ...g VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Remove VLAN Press Enter to remove an existing VLAN ...

Page 77: ...Note Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter to save all configurations Note This item appears whe...

Page 78: ... for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consective Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address Detection is not performed Policy Options available automatic manual Default setting is automatic Save Changes and Exit Press Enter ...

Page 79: ...etup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Page 80: ...EH cloak individual banks and mask deferred error interrupts from each bank Options available Auto Enabled Disabled Default setting is Auto Core Performance Boost Enable Disable the Core Performance Boost function Options available Auto Disabled Default setting is Auto Global C State Control Controls the IO based C state generation and DF C states Options available Auto Enabled Disabled Default se...

Page 81: ...tions available Auto Enabled Disabled Default setting is Auto SNP Memory RMP Table Coverage Enabled Enter system memory is covered Options available Auto Enabled Disabled Custom Default setting is Auto SMEE Control secure memory encryption enable Options available Auto Enabled Disabled Default setting is Auto Action on BIST Failure Action to take when a CCD BIST failure is detected Options availab...

Page 82: ...ept or decline enabling CCDs processor cores and threads When accepted you can control the number of CCDs to be used the number of cores to be used and whether to enable or disable Simultaneous Multithreading Technology SMT support SMT Control Can be used to disable symmetric multithreading To re enable SMT a POwer CYCLE is needed after select the Enable option Select Auto base on BIOS PCD PcdAmdS...

Page 83: ...ble Disable Default setting is Auto L1 Region Prefetcher Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Options available Auto Enable Disable Default setting is Enable L2 Stream HW Prefetcher Enable Disable L2 Stream HW Prefetcher Options available Auto Enable Disabled Default setting is Enable L2 Up Down...

Page 84: ...BIOS Setup 84 5 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto ...

Page 85: ...Disable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Frezze DF module queues on error Options available Auto Enabled Disabled Default setting is Auto CC6 memory region encryption Controls whether or not the CC6 save restor memory is encrypted Options available Auto Enabled Disabled Default setting is Auto System probe filter Enable...

Page 86: ...efault setting is Auto Poison scrubber control Enable Disable the Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber limit Sets the redirect scrubber limit Options available Auto 2 4 8 Infinite ...

Page 87: ... remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Auto Do not remap Attempt to remap Default setting is Auto DRAM map inversion Enable Disable the DRAM map inversion function Options available Auto Enabled Disabled Default setting is Auto...

Page 88: ...Options available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT remote relative distance Sets the remote socket distance for 2P systems as near 2 8 or far 3 2 Options available Auto Near Far Default setting is Auto ...

Page 89: ...ault setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps 3 link xGMI max speed Specifies the max speed of 3 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps xGMI TXEQ Mode Configures xGMI TXEQ RX vetting Mode Options available Auto TXEQ_Disable...

Page 90: ...Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced items Memory MBIST Press Enter for configuration of advanced items ...

Page 91: ...nel at 3200MHz function select Accept at warning message change Overclock from Auto to Enabled and then set memory speed to 3200MHz DRAM Controller Configuration Press Enter to configure DRAM Controller Configuration CAD Bus Configuration Press Enter to configure CAD Bus Configuration Data Bus Configuration Press Enter to configure Data Bus Configuration Common RAS Press Enter to configure Common ...

Page 92: ...und UrgRefLimit DRAM Maximum Activate Count Options available Auto Unlimited MC 200K 300K 400K 500K 600K 700K Default setting is Auto DRAM Refresh Rate Options available 7 8 usec 3 9 usec Default setting is 7 8 usec Self Refresh Exit Staggering Options available Disabled Trfc 3 Trfc 4 Default setting is Disabled Cmd2T Selects the Cmd2T mode on ADDR CMD Options available Auto 1T 2T Default setting ...

Page 93: ...iguration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto ...

Page 94: ...3 1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Default setting is Auto ...

Page 95: ...tion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurable when DRAM Address Command Parity Retry is set to Enabled Write CRC Enable Enable Disable the Write CRC function Options available Auto Enabled Disabled Default setting is Auto DRAM Write CRC Enable...

Page 96: ...ems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable Options available Auto Enabled Disabled Default setting is Auto DRAM UECC Retry Enable Disable DRAM UECC Retry Options available Auto Enabled Disabled Default setting is Auto ...

Page 97: ...rameter Description Security TSME Enable Disable Transparent SME Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available Auto Enabled Disabled Default setting is Auto ...

Page 98: ...U Training Press Enter to configure PMU Training DFE Traing Enable Disable DDR power down mode Options available Auto Enabled Disabled Default setting is Auto FFE Write Training Auto Enabled Disabled Default setting is Auto PMU Pattern Bits Controls Auto Manual Default setting is Auto ...

Page 99: ... No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address Hash Bank Enable Disable bank address hashing Options available Auto Enabled Disabled Default setting is Auto Address Hash CS Enable Disable CS address hashing Options available Auto Enabled Disabled...

Page 100: ...BIOS Setup 100 5 3 3 3 NVDIMM Parameter Description NVDIMM Disable NVDIMM N feature for memory margin tool Options available No Yes Default setting is No ...

Page 101: ...e Mode Data Eye Mode Default setting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Disable to report 2D data eye results in ABL log for each DQ Chipselect and Channel Options available Auto Enabled Disabled Default setting is Auto Data Eye Press Enter to configure advan...

Page 102: ...ol function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select Lower 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select ECC This item is configurable when Aggressor Static ...

Page 103: ...Voltage Sweep 1D Timing Sweep 2D Full Data Eye Worst Case Margin Only Default setting is Worst Case Margin Only Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available Per Chip Select Per Nibble Default setting is Worst Case Margin Only Read Voltage Sweep Step Size Configures the step size for read Data Eye voltage sweep Options available 1 2 4 Default setting is 2...

Page 104: ...numeration ARI Forwarding Enable for each downstream port Options available Auto Enabled Disabled Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices Auto Disabled Options available Auto Enabled Disabled Default setting is Auto SMU Common Options Press Enter for configuration of advanced items NBIO RAS Common Options Press Enter for configuration...

Page 105: ...available Auto Manual Default setting is Auto Loopback Mode Enabled Disabled PCIe Loopback mode Options available Auto Enabled Disabled Default setting is Auto CV test Set this to Enabled to support running PCIECV tool Auto preserve hardware defaults Options available Auto Enabled Disabled Default setting is Auto CAC Weight Adjustment EDC Mode select Options available Auto Enabled Disabled Default...

Page 106: ...Control Selects use the fused TDP or set customized TDP TDP is used to define the RC thermal model only Options available Auto Manual Default setting is Auto cTDP Display cTDP information EfficiencyModeEn Options available Auto Enabled Default setting is Auto Package Power Limit Control Selects use the fused PPT or set customized PPT PPT will be used as the ASIC power limit Options available Auto ...

Page 107: ...isable Options available Auto Enabled Disabled Default setting is Auto DLMM Support Select DLMM support enable or disable Options available Auto Enabled Disabled Default setting is Auto BoostFmaxEn Options available Auto Enabled Default setting is Auto EDC Current Options available Enable Disable Default setting is Disable LCLK Frequency Control Press Enter for advanced configuration DF PSTATE Mod...

Page 108: ...bit of 0 indicates LOW serverity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFlood Reporting The value may be used to enanle SyncFlood reporting to APML Options available Enabled Disabled Default setting is Disabled Egress Poison Mask High Enables mask for masking of errors log...

Page 109: ...Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable Disable the Log Poison Data from SLINK feature Options available Enabled Disabled Default setting is Disabled PCIe Aer Reporting Mechanism Selects the method of reporting AER errors from PCI Express O...

Page 110: ...arameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items Miscellaneous Options Press Enter for configuration of advanced items ...

Page 111: ...S Setup 5 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is Power off ...

Page 112: ...ALink RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to system controller Options available Auto Enabled Disabled Default setting is Auto ...

Page 113: ... 45 BIOS Setup 5 3 5 3 Miscellaneous Options Parameter Description Miscellaneous Options Boot Time Enable Options available Auto Enabled Disabled Default setting is Auto ...

Page 114: ...NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P1 NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P2 NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P3 NTB Enable Options available Auto Enable Default setting is Auto ...

Page 115: ...nable Disable the ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number of PMU debug messages Options available Auto Enabled Disabled Default setting is Auto Note This item appears when ABL Console Out Control is set to Enabled ...

Page 116: ...ter Description Workload Tuning Workload Profile Select the profile for different workloads Default setting is Auto Performance Tracing Enable to allow capturing performance traces Options available Auto Enabled Disabled Default setting is Auto ...

Page 117: ...king for protect ROM part Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn Reserved 1M bytes MMIO space on 1M boundary when iLA TraceMemoryEn disabled Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn reserved MMIO Reserved function SRIS mode debug Control SRIS mode debug Options available Auto Enabled Disabled Default setting is Auto ...

Page 118: ...Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for uncorrected errors Options available Polled NMI Default setting is NMI PCIe GHES Notify Type Selects the Notification type for PCIe corrected errors Options available Polled SCI Default setting is Polled...

Page 119: ...RR Notify Type Selects the Notification type for CCIX deffered error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX corrected error Options available Polled SCI Default setting is Polled DDR4 DRAM Hard Post Package Repair This feature allows spare DRAM rows to replace malfunctioning rows via an in field repair mecha...

Page 120: ...er to access the related submenu screen Parameter Description PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available Enabled Disabled Default setting is Enabled North Bridge Press Enter for configuration of advanced items Fabric Resource Press Enter for configuration of advanced items ...

Page 121: ...er Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU0 Information Press Enter to view information related to CPU 0 CPU1 Information Press Enter to view information related to CPU 1 ...

Page 122: ...BIOS Setup 122 5 5 2 Fabric Resource Parameter Description Fabric Resource Socket 0 1 NBIO_ PCIe Bus Number Change Socket 0 1 NBIO_ PCIe Bus Number ...

Page 123: ... Default setting is Do Nothing OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configures OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes Please note that this item is configurable when OS Watchdog Timer is set to Enabled OS Wtd Timer Policy C...

Page 124: ...ed 2 minutes 4 minutes 6 minutes Default setting is 2 minutes System Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Page 125: ...e SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options availabl...

Page 126: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Page 127: ...g is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information VLAN Support Set to BMC enabled diisabled VLAN Options available Enabled Disable...

Page 128: ...work during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Enable Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IP...

Page 129: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Page 130: ...ooting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys from the BIOS database Options avail...

Page 131: ... Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set New Append ...

Page 132: ...ber of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Boot mode select Selects the boot ...

Page 133: ...ure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Page 134: ...rities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 135: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 136: ...ne so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options availabl...

Page 137: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource r...

Page 138: ...BIOS Setup 138 This page intentionally left blank ...

Reviews: