background image

- 79 -

BIOS Setup

5-2-12 

NVMe Configuration

Parameter

Description

NVMe controller and Drive 
Information

Displays the NVMe devices connected to the system.

Summary of Contents for G482-Z50

Page 1: ...G482 Z50 G482 Z51 AMD EPYCTM 7002 Series Processor Server User Manual Rev 1 0 ...

Page 2: ...nd BMC firmware Service Guide detailed information steps about the installation configuration and use of this product server barebones covering hardware BIOS Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes Please see the support section of the online product page to check the current availability of these documents For More Inform...

Page 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Page 4: ...ticular attention to the plug electrical outlet and the point where the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing CAUTION Do not operate the server for lon...

Page 5: ...scharge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully The...

Page 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Page 7: ...23 2 7 Hard Disk Drive LEDs 24 Chapter 3 System Hardware Installation 25 3 1 Removing and Installing the Top Rear Cover 26 3 2 Removing and Installing the Air Duct 27 3 3 Removing and Installing the GPU Fan Module 28 3 4 Installing the GPU Card Optional 29 3 5 Installing the PCIe Card 32 3 5 1 G482 Z50 32 3 5 2 G482 Z51 34 3 6 Removing and Installing the Heat Sink 36 3 7 Removing and Installing th...

Page 8: ...Redish Host Interface Settings 65 5 2 4 Legacy Video Select 66 5 2 5 AST2500 Super IO Configuration 67 5 2 6 S5 RTC Wake Settings 69 5 2 7 Serial Port Console Redirection 70 5 2 8 CPU Configuration 73 5 2 9 AMI Graphic Output Protocol Policy 74 5 2 10 PCI Subsystem Settings 75 5 2 11 USB Configuration 77 5 2 12 NVMe Configuration 79 5 2 13 SATA Configuration 80 5 2 14 Network Stack Configuration 8...

Page 9: ...ve BBS Priorities 129 5 8 4 UEFI Application Boot Priorities 130 5 9 Save Exit Menu 131 5 10 ABL POST Codes 132 5 10 1 Start Processor Test Points 132 5 10 2 Memory test points 132 5 10 3 PMU Test Points 132 5 10 4 Original Post Code 133 5 10 5 CPU test points 134 5 10 6 Topology test points 134 5 10 7 Extended memory test point 134 5 10 8 Gnb Earlier init 135 5 10 9 PMU test points 138 5 10 10 AB...

Page 10: ... 10 5 11 8 0xADXX assigned for AGESA DF Module 151 5 11 9 0xAFXX assigned for AGESA FCH Module 151 5 12 BIOS POST Beep code AMI standard 153 5 12 1 PEI Beep Codes 153 5 12 2 DXE Beep Codes 153 ...

Page 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Page 12: ...ide 2 x 10Gb s BASE T LAN ports Intel X550 AT2 1 x 10 100 1000 management LAN Front side 2 x 1Gb s BASE T LAN ports Intel I350 AM2 Expansion Slot System is validated for population with a uniform GPU model Support is not provided for mixed GPU populations G482 Z50 10 x PCIe x16 slots Gen3 x16 bus for GPU 1 x PCIe x16 Gen3 x8 bus half length low profile slot in front occupied by CRA3338 HBA 1 x PCI...

Page 13: ...t swappable HDD SSD bay NOTE SATA devices supported only SAS SATA SAS supported SATA supported Internal I O 1 x TPM header 1 x Front panel header Front I O 2 x USB3 0 connector 1 x VGA connector 2 x RJ45 LAN connector 1 x MLAN connector reserved enabled by cable switch 1 x Power button with LED 1 x ID button with LED 1 x Reset button 1 x NMI button 1 x System status LED 1 x HDD access LED Rear I O...

Page 14: ...Redirection Settings PAM Order Settings SSL Settings SMTP Settings OS Compatibility Windows Windows Server 2016 X2APIC 256T not supported Windows Server 2019 with KB4490481 Red Hat Enterprise Linux 7 6 x64 or later Red Hat Enterprise Linux 8 0 x64 or later SUSE Linux Enterprise Server 12 SP4 x64 or later SUSE Linux Enterprise Server 15 SP1 x64 or later Ubuntu 18 04 LTS x64 or later VMware ESXi 6 5...

Page 15: ...perties Operating temperature 10 C to 35 C Non operating temperature 40 C to 60 C Operating humidity 8 80 non condensing Non operating humidity 20 95 non condensing System Dimension 4U 448 W x 176 H x 880 D mm 17 64 W x 6 93 H x 34 65 D inch ...

Page 16: ...Hardware Installation 16 1 3 System Block Diagram 1 3 1 G482 Z50 1 3 2 G482 Z51 ...

Page 17: ...ption No Description 1 RAID Card Slot 5 USB 3 0 Port x 2 2 Front Panel LEDs and Buttons 6 VGA Port 3 10GbE LAN Port x 2 7 2 5 inch HDD Bay x 10 0 to 9 4 10 100 1000 Server Management LAN Port 8 3 5 inch HDD Bay x 12 12 to 23 2 1 1 G482 Z50 HDD 12 HDD 15 HDD 18 HDD 21 HDD 13 HDD 16 HDD 19 HDD 22 HDD 14 HDD 17 HDD 20 HDD 23 HDD 0 HDD 2 HDD 4 HDD 6 HDD 8 HDD 1 HDD 3 HDD 5 HDD 7 HDD 9 ...

Page 18: ...l LEDs and Buttons 4 USB 3 0 Port x 2 2 10GbE LAN Port x 2 5 VGA Port 3 10 100 1000 Server Management LAN Port 6 2 5 inch HDD Bay x 10 0 to 9 Go to the section 2 3 Front Panel Buttons and LEDs for detail description of function LEDs HDD 0 HDD 2 HDD 4 HDD 6 HDD 8 HDD 1 HDD 3 HDD 5 HDD 7 HDD 9 ...

Page 19: ...PCIe x16 Slot x 8 5 LAN Module 3 10GbE LAN Port x 2 optional 6 Power Supply Unit x 3 PSU 1 to 3 2 2 1 G482 Z50 2 2 2 G482 Z51 1 2 3 4 5 No Description No Description 1 PCIe x16 Slot x 8 4 LAN Module 2 10GbE LAN Port x 2 optional 5 Power Supply Unit x 3 PSU 1 to 3 3 10 100 1000 Server Management LAN Port PSU 3 PSU 2 PSU 1 PSU 3 PSU 2 PSU 1 ...

Page 20: ...tem temperature Blink Indicates non critical condition may include Redundant power module failure Temperature and voltage issue Chassis intrusion N A Off Indicates system is not ready may include POST error NMI error Processor or terminator is missing 4 NMI Button Press this button for the server to generate a NMI to the processor If multiple bit ECC errors occur the server will effectively be han...

Page 21: ...ription 1 GbE Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or reception is occurring N A Off No data transmission or reception is occurring ...

Page 22: ...iption 1 GbE Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or reception is occurring N A Off No data transmission or reception is occurring ...

Page 23: ... Smart Standby Mode Green Blinking 2Hz Power supply firmware update Amber On AC cord unplugged AC power lost but a second power supply in parallel still having AC input power Power supply critical events that cause a shutdown such as OTP OCP UVP OVP and fan failure Amber Blinking 0 5Hz Power supply warning events where the power supply continues to operate such as high temperature high power high ...

Page 24: ...ID Card or SW RAID Card Disk LED LED on Back Panel Amber Removed HDD Slot LED on Back Panel Disk LED Removed HDD Slot Green ON 1 OFF Green OFF ON OFF ON 1 OFF OFF ON OFF ON Alternately Low Speed 2 Hz 3 3 OFF OFF Green Amber Green ON 1 OFF Green Green OFF OFF Amber Amber Amber OFF OFF Amber OFF LED 2 HDD Present No HDD Green ON OFF Information shown in the tables below applies to both G482 Z50 and ...

Page 25: ...er you are working inside the system case If possible wear a grounded wrist strap when you are working inside the system case Alternatively discharge any static electricity by touching the bare metal system of the system case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do ...

Page 26: ...remove the top rear cover 1 Remove the single screw securing the cover 2 Loosen the two thumbnail screws securing the top rear cover in place 3 Slide the cover towards the rear and remove the cover in the direction indicated 4 Follow steps 1 4 in reverse order to re install the top rear cover 1 2 2 3 3 The image below shows the top rear cover removal process for G482 Z50 The same process applies t...

Page 27: ...all the air duct align the rear edge of air duct with the GPU module brackets ensuring that the arrows on the air duct face the rear of the system as shown in the image below and then push down the air duct into chassis until it firmly seats Before you remove the top rear cover Make sure the system is not turned on or connected to AC power The section applies to G482 Z50 only ...

Page 28: ...fan module in place 3 Lift up to remove the GPU fan module from the system 4 Follow steps 1 3 in reverse order to re install the GPU fan module 1 2 2 3 Before you remove the GPU fan module Make sure the system is not turned on or connected to AC power Disconnect all necessary cable connections Failure to observe these warnings could result in personal injury or damage to the equipment This section...

Page 29: ...two screws to secure the GPU card in place 6 Install the three screws to secure the GPU card bracket in place 1 1 1 2 Before you install the GPU card Voltages can be present within the server whenever an AC power source is connected This voltage is present even when the main power switch is in the off position Ensure that the system is powered down and all power sources have been disconnected from...

Page 30: ...System Hardware Installation 30 3 4 5 ...

Page 31: ... 31 System Hardware Installation 6 6 6 ...

Page 32: ...g a PCIe card Make sure the system is not turned on or connected to AC power Failure to observe these warnings could result in personal injury or damage to the equipment Follow these instructions to install the PCIe card 1 Pull out the thumbnail screw securing the GPU card cage in place 2 Flip over the GPU card cage in the direction indicated 3 Remove the two screws securing the PCIe card slot cov...

Page 33: ... 33 System Hardware Installation 3 5 4 ...

Page 34: ...urces have been disconnected from the server prior to installing a PCIe card Make sure the system is not turned on or connected to AC power Failure to observe these warnings could result in personal injury or damage to the equipment Follow these instructions to install the PCIe card 1 Remove the two screws securing the PCIe card slot covers in place and remove the PCIe card slot covers 2 Insert th...

Page 35: ... 35 System Hardware Installation 2 3 ...

Page 36: ...e surface Open the system according to the instructions WARNING Failure to turn off the server before you start installing components may cause serious damage Do not attempt the procedures described in the following sections unless you are a qualified service technician Follow these instructions to install the heatsink 1 Loosen the four captive screws securing the heat sink in place in reverse the...

Page 37: ...ections unless you are a qualified service technician Follow these instructions to install the CPU 1 Loosen the three captive screws securing the CPU cover in sequential order 1g2g3 2 Flip open the CPU cover 3 Remove the CPU carrier from the CPU frame using the handle on the CPU carrier 4 Using the handle on the CPU carrier insert the new CPU carrier with CPU installed into the CPU frame NOTE Ensu...

Page 38: ...e Installation 38 CPU 4 5 6 1 3 2 7 When installing the heat sink over the CPU use T20 Lobe driver to tighten the 4 captive nuts in sequential order 1g2g3g4 The screw tightening torque 16 1 1 2 kgf cm 14 0 1 0 lbf in ...

Page 39: ..._P0_F0 DIMM_P0_F1 DIMM_P0_G0 DIMM_P0_G1 DIMM_P0_H0 DIMM_P0_H1 DIMM_P1_L1 DIMM_P1_L0 DIMM_P1_K1 DIMM_P1_K0 DIMM_P1_J1 DIMM_P1_J0 DIMM_P1_I1 DIMM_P1_I0 DIMM_P1_M0 DIMM_P1_M1 DIMM_P1_N0 DIMM_P1_N1 DIMM_P1_O0 DIMM_P1_O1 DIMM_P1_P0 DIMM_P1_P1 Read the following guidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same ...

Page 40: ...he plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 8 3 DIMM Population Rule Be sure to install DDR4 DIMMs on this motherboard The initial DIMMs installed must be installed in the primary CPU CPU0 memory slots first Install the memory in alphabetic order starting with Bank A If the system features ...

Page 41: ...rted 1 2 DIMMs Populated DIMM 2S2R 2S4R 1 2 2933 2666 1 2V Frequency MT s LRDIMM Maximum Frequency Supported 4DR 2 1 DIMMs Populated DIMM 2S2R 2S4R 1 1 2 2 1 1 3200 3200 2933 Not Supported 2933 1 2V Frequency MT s 1R 1 package rank of SDP DRAMs 2R 2 package rank of SDP DRAMs 2DR 2 package rank of DDP DRAMs 4DR 4 package rank of DDP DRAMs 2S2R 2S4R 2S8R 2 package rank of 2 4 8 high 3DS DRAMs ...

Page 42: ... 2 Extend the locking lever 3 Pull the locking lever to remove the HDD tray 4 Slide the hard disk drive into the blank HDD tray 5 Secure the hard drive to the tray with the four screws as shown Do not over tighten the screws Slide the hard drive tray into the bay until it locks in place CAUTION We strongly recommend using enterprise level hard disk drives in the Gigabyte server system For more inf...

Page 43: ... Slide the hard drive into the blank HDD tray in the indicated direction 6 Make sure the hard drive is secured in the HDD tray Slide the hard drive tray into the bay until it locks in place CAUTION We strongly recommend using enterprise level hard disk drives in the Gigabyte server system For more information of recommended HDDs please visit the Gigabyte website https www gigabyte com and search f...

Page 44: ...ss the release button 2 Extend the locking lever 3 Pull the locking lever to remove the HDD tray 4 Slide the hard disk drive into the blank HDD tray 5 Slide the hard drive tray into the bay until it locks in place CAUTION We strongly recommend using enterprise level hard disk drives in the Gigabyte server system For more information of recommended HDDs please visit the Gigabyte website https www g...

Page 45: ...bserve these warnings could result in personal injury or damage to the equipment FAN 1 FAN 2 FAN 3 FAN 4 FAN 5 FAN 6 Follow these instructions to replace the system fan module For all system fan modules 1 Grasp the finger slots of the fan module and pull up to remove the fan module 2 Reverse the previous steps to install the replacement fan module 2 1 1 The images below show the system fan module ...

Page 46: ... screws securing the cover 2 Slide the cover towards the rear and remove the cover in the direction indicated 3 Reverse the previous steps to install the top front cover 1 1 1 2 2 Skip this section if you are not going to replace the PCIe RAID card The image below shows the Top Front Cover removal process for G482 Z50 The same process applies to G482 Z51 ...

Page 47: ...irection indicated to disconnect the PCIe RAID 5 Reverse the previous steps to install the replacement PCIe RAID card 2 3 1 This section applies to G482 Z51 only Voltages can be present within the server whenever an AC power source is connected This voltage is present even when the main power switch is in the off position Ensure that the system is powered off and all power sources have been discon...

Page 48: ...System Hardware Installation 48 4 ...

Page 49: ...t the power supply using the handle 4 Insert the replacement power supply firmly into the chassis Connect the AC power cord to the replacement power supply 1 3 2 4 CAUTION In order to reduce the risk of injury from electric shock disconnect AC power from the power supply before removing the power supply from the system Please see Section 2 2 Rear View for installation sequence The images below sho...

Page 50: ...he LAN module 1 Press the retaining clip on the right side of the LAN module in the direction indicated 2 Pull out the LAN module using the handle 3 Insert the replacement LAN module firmly into the chassis 1 2 3 The images below show the LAN Module removal process for G482 Z50 The same process applies to G482 Z51 ...

Page 51: ... 51 System Hardware Installation 3 16 Cable Connections 3 16 1 G482 Z50 1 1 2 3 4 5 6 7 8 4 7 2 5 6 8 3 9 10 10 11 9 11 Motherboard to PCIe Board and Middle Board ...

Page 52: ...System Hardware Installation 52 G482 Z50 3 5 HDD Backplane Board 2 5 HDD Backplane Board Daughter Board 1 Daughter Board 2 2 2 1 1 3 3 4 5 6 4 5 6 7 8 7 8 HDD Backplane Boards to Daughter Boards ...

Page 53: ... 53 System Hardware Installation 3 16 2 G482 Z51 1 2 3 4 5 6 19 20 20 21 1 2 3 4 7 8 9 10 11 12 5 6 7 8 12 11 9 10 17 15 13 14 15 16 18 17 18 21 16 14 13 19 Motherboard to PCIe Board and Middle Board ...

Page 54: ...System Hardware Installation 54 G482 Z51 1 2 3 2 1 3 Motherboard to 2 5 HDD Backplane Board ...

Page 55: ...MLAN NCSI Signal 18 Slimline Connector Miscellaneous 19 TPM Module Connector 20 Slimline Connector SATA 0 3 for CPU0 21 Slimline Connector SATA 4 7 for CPU0 22 IPMB Connector 23 2 x 15 Pin HDD Back Plane Board Connector 24 For G482 Z50 Slimline Connectors XGMI Signal For G482 Z51 Slimline Connectors PCIe Signal 25 Serial Port Cable Connector CPU0 CPU1 DIMM_P0_D1 DIMM_P0_D0 DIMM_P0_C1 DIMM_P0_C0 DI...

Page 56: ..._P1_K1 DIMM_P1_K0 DIMM_P1_J1 DIMM_P1_J0 DIMM_P1_I1 DIMM_P1_I0 DIMM_P1_M0 DIMM_P1_M1 DIMM_P1_N0 DIMM_P1_N1 DIMM_P1_O0 DIMM_P1_O1 DIMM_P1_P0 DIMM_P1_P1 1 2 1 2 J1 ON DIP 1 2 3 4 ON J1 1 2 3 4 OFF BIOS Defined BIOS Defined Normal Default Clear Supervisor Password BIOS_PWD HSMB_SEL PMBUS_SEL BIOS_RCVR BIOS Recovery Mode Normal Default ON OFF CLR_CMOS Default Enable 1 2 3 Clear CMOS Jumper Information ...

Page 57: ... caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this chapter ...

Page 58: ... Bridge South Bridge and System event logs Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not t...

Page 59: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Page 60: ...on number of the BIOS setup utility BIOS Information Project Name Displays the project name information Project Version Displays version number of the BIOS setup utility Build Date and Time Displays the date and time when the BIOS setup utility was created BMC Information BMC Firmware Version Displays version number of the BIOS setup utility Processor Information CPU 0 Brand String CPU 1 Brand Str...

Page 61: ...ion information Onboard LAN Information LAN1 MAC Address Note2 Displays LAN MAC address information LAN2 MAC Address Note2 Displays LAN MAC address information System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note1 This section will display capacity and frequency information of the memory that the custome...

Page 62: ... Setup 62 5 2 Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen ...

Page 63: ...figuration Security Device Support Select Enable to activate TPM support feature Options available Enable Disable Default setting is Enable SPI TPM Support Options available Enabled Disabled Default setting is Enabled 5 2 1 Trusted Computing ...

Page 64: ...BIOS Setup 64 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Page 65: ...Displays the Redish version supported by BIOS Authentication Mode Press Enter to select the authentication mode Options available Basic Authentication Session Authentication Default setting is Basic Authentication Redish BMC Settings IP Address Press Enter to configure the IP address IP Mask Address Press Enter to configure the IP mask address IP Port Press Enter to configure the IP port ...

Page 66: ...OnBrd Ext VGA Select Note Select between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard Note This configurable option will be displayed when Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Page 67: ... 67 BIOS Setup 5 2 5 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information ...

Page 68: ...ngs Change Settings Note2 Select an optimal setting for the Super I O device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 ...

Page 69: ... Enable or disable system wake on alarm event Select Fixed Time system will wake on the time HH MM SS specified Select Dynamic Time and the system will wake at the current time plus an increase in minute s Options available Disabled Fixed Time Dynamic Time Default setting is Disabled ...

Page 70: ...on the available COM ports Serial Port for Out of Band Management Windows Emergency Management Services EMS Console Redirection Note Selects a COM port for EMS console redirection EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled COM1 SOL Console Redirection ...

Page 71: ...th slow devices may require more than 1 stop bit Options available 1 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals ...

Page 72: ... Console Redirection Settings Out of Band Mgmt Port Selects a serial port to remotely manage a Windows server OS Options available COM1 SOL Default setting is COM1 SOL Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is VT UTF8 Bits per second Selects the transfer rate for console redirection Options available 9600 ...

Page 73: ...tions available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is Enabled CPU 0 Information Press Enter to view more information related to CPU 0 CPU 1 Information Press Enter to view more information related to CPU 1 ...

Page 74: ...BIOS Setup 74 5 2 9 AMI Graphic Output Protocol Policy Parameter Description ASPEED Graphics PCI Adapter ASPEED Graphics Driver Output Select Press Enter to select output interface ...

Page 75: ...n ROM for the related PCI E slot Options available Enabled Disabled Default setting is Enabled Onboard LAN 1 Controller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN 1 I O ROM Note2 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Dev...

Page 76: ...m has SR IOV capable PCIe devices this item Enable Disable Single Root IO Virtualization Support Options available Enabled Disabled Default setting is Enabled PCI E AER Enabled Enable Disable PCI E AER Options available Enabled Disabled Default setting is Disabled ...

Page 77: ...ff Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled Port 60 64 Emulation Enables the I O port 60h 64h emulation support This should be enabled for the complete USB Keyboard Legacy support ...

Page 78: ...or a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM0 1 00 AMI HDisk0 1 00 Generic Flash Disk 8 07 ADATA USB Flash Drive 1100 Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media wil...

Page 79: ... 79 BIOS Setup 5 2 12 NVMe Configuration Parameter Description NVMe controller and Drive Information Displays the NVMe devices connected to the system ...

Page 80: ...BIOS Setup 80 5 2 13 SATA Configuration ...

Page 81: ...setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Disabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled IPSEC Certificate Note Enable Disable the IPSEC Certificate feature Options available Enabled Disabled Default setting is Enabled PXE bo...

Page 82: ...anced items Channel A BC D E F G H DIMM0 Presence DIMM1 Presence Chipset Bank Interleave Dram EC Dram Parity Dimm Sensor Fine Grain Mode CPU 1 Press Enter for configuration of advanced items Channel I J K L M N O P DIMM0 Presence DIMM1 Presence Chipset Bank Interleave Dram EC Dram Parity Dimm Sensor Fine Grain Mode ...

Page 83: ...Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add Attempt Press Enter for configuration of advanced items Delete Attempt Press Enter for configuration of advanced items Change Attempt Order Press Enter for configuration of advanced items ...

Page 84: ...n Press Enter for configuration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration N A ...

Page 85: ... 85 BIOS Setup 5 2 18 Intel R I350 Gigabit Network Connection ...

Page 86: ... Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the Network Interface Controller PCI D...

Page 87: ... 87 BIOS Setup 5 2 19 VLAN Configuration ...

Page 88: ... to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Note Enable Disable the VLAN Options available Enable Disable Default setting is Disabled Remove VLAN Press Enter to remove an existing VLAN Note O...

Page 89: ...e Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter and then choose to save or discard the changes made Note This item will ap...

Page 90: ...e Table Gateway addresses DNS addresses Interface ID The 64 bit alternative interface ID for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor Solicitaion messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Addres Detection is not performed Policy Save Change...

Page 91: ... 91 BIOS Setup 5 2 22 Intel R Ethernet Controller X550 ...

Page 92: ... Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the Network Interface Controller PCI D...

Page 93: ...etup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Page 94: ...f CCDs to be used the number of cores to be used and whether to enable or disable symmetric multithreading Prefetcher settings Press Enter for more options L1 Stream HW Prefetcher Option to enable or disable L1 Stream HW Prefetcher Options available Disable Enable Auto Default option is Auto L2 Stream HW Prefetcher Option to enable or disable L2 Stream HW Prefetcher Options available Disable Enabl...

Page 95: ...3 ASIDs 509 ASIDs Auto Default option is Auto SEV ES ASID Space Limit Control Space limit control for SEV ES ASIDs Options available Auto Manual Default option is Auto Streaming Stores Control Enables or disables the streaming stores functionality Options available Disabled Enabled Auto Default option is Auto Local APIC Mode Sets the Local APIC mode Options available xAPIC x2APIC Auto Default opti...

Page 96: ...l Allows you to enable or disable poison scrubber control Options available Disabled Enabled Auto Default option is Auto Redirect scrubber control Allows you to enable or disable redirect of scrubber control Options available Disabled Enabled Auto Default option is Auto Redirect scrubber limit Allows you to set the redirect scrubber limit Options available 2 4 8 Infinite Auto Default option is Aut...

Page 97: ...to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Do not remap Attempt to remap Auto Default option is Auto DRAM map inversion Inverting the map will cause the highest memory channels to get assigned the lowest addresses in the system Options available Disable...

Page 98: ...t Auto Default option is Auto Disable DF to external IP Sync Flood Propagation Disable SyncFlood to UMC downstream slaves Options avaialble Sync flood disabled Sync flood enabled Auto Default option is Auto Disable DF sync flood propagation Enable Disable DF SyncFlood Options avaialble Sync flood disabled Sync flood enabled Auto Default option is Auto Freeze DF module queues on error Controls DF P...

Page 99: ...ll be capped at AMD guidelines To enable 2 DIMMS per Channel at 3200MHz function select Accept at warning message switch Overclock from Auto to Enabled and then set memory speed to 3200Mhz DRAM Controller Configuration Press Enter to configure DRAM controller options DRAM Power Options Cmd2T Gear Down Mode CAD Bus Configuration Press Enter to configure CAD Bus options CAD Bus Timing User Controls ...

Page 100: ...hat alters how applications get assigned to physical locations within the memory modules When this option sets to Auto it is null Options available Enabled Disabled Auto Default option is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Enabled Disabled Auto Default option is Auto Address Hash Bank Enable or disable bank address hashing Options available Disabled Enabled Aut...

Page 101: ...atic Lane Control Aggressor Static Lane Select Upper 32 bits Aggressor Static Lane Select Lower 32 bits Aggressor Static Lane Select ECC Aggressor Static Lane Value Target Static Lane Control Target Static Lane Select Upper 32 bits Target Static Lane Select Lower 32 bits Target Static Lane Select ECC Target Static Lane Value Data Eye Type Worst Case Margin Granularity Read Voltage Sweep Step Size ...

Page 102: ...Ie ARI Support Enables Alternative Routing ID Interpretation Options available Disable Enable Auto Default option is Auto PCIe Ten Bit Tag Support Enables PCIe ten bit tags for supported devices Auto Disabled Options available Disable Enable Auto Default option is Auto HD Audio Enable Enables or disables HD Audio Options available Enable Disabled Auto Default option is Auto ...

Page 103: ...power efficiency optimized CCLK DPM settings Options available Auto Enabled Default option is Auto Package Power Limit Control Auto Use the fused PPT Manual User can set PPT PPT will be used as the ASIC power limit Options available Manual Auto Default option is Manual xGMI Link Width Control Auto Use degault xGMI link width controller Manual User can set custom xGMI link width controller settings...

Page 104: ...d to APML When set to FALSE that reporting will be disabled Options available Enabled Disabled Default option is Disabled Egress Poison Mask High Enter a value These set the enable mask for masking of errors logged in EGRESS_POISON_STATUS For each bit set to 1 errors are masked For each bit set to 0 errors trigger response actions Egress Poison Mask Low Enter a value These set the enable mask for ...

Page 105: ...erted to Okay responses Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default option is Log Errors in MCA Log Poison Data from SLINK This value specifies whether poison data propogated from SLINK will generate a deferred error When this value is set to TRUE deferred errors are enabled When set to FALSE errors are not generated Options available Enabled Disabled Default option i...

Page 106: ...o Enable AER Cap Enables Advanced Error Reporting Capabilty Options available Enable Disabled Auto Default option is Auto Early Link Speed Sets Early Link Speed Options available Auto Gen1 Gen2 Default option is Auto Hot Plug Handling mode Controls the Hot Plug Handling mode Options available A0 Mode OS First No Error Handling OS First Error Handling Not Implementd Firmware First Not Implemented A...

Page 107: ... Sata Disabled AHCI Prefetch Function Enable or disable Sata Disabled AHCI Prefetch Function Options available Disabled Enabled Auto Default setting is Auto Aggressive SATA Device Sleep Port 0 Options available Disabled Enabled Auto Default setting is Auto Aggressive SATA Device Sleep Port 1 Options available Disabled Enabled Auto Default setting is Auto SATA Controller options Press Enter for mor...

Page 108: ...if Uart 3 is enabled Options available Disabled Enabled Auto Default setting is Auto Uart 2 Enable no HW FC Options available Disabled Enabled Auto Default setting is Auto Uart 3 Enable no HW FC Options available Disabled Enabled Auto Default setting is Auto ESPI Configuration Options Press Enter for more options ESPI Enable Options available Disabled Enabled Auto Default setting is Auto eMMC Opti...

Page 109: ...nter for more options ALink RAS Support Options available Disabled Enabled Auto Default setting is Auto Reset after sync flood Enable AB to forward downstream sync flood message to system controller Options available Disabled Enabled Auto Default setting is Auto ...

Page 110: ...BIOS Setup 110 5 3 6 NTB Common Options Parameter Description NTB Common Options NTB Enable Enable or disable OnChip SATA controller Options available Auto Enable Default setting is Auto ...

Page 111: ...able Auto Default setting is Auto ABL Basic Console Out Control Enable Enable Basic ConsoleOut Function for ABL Disable Disable Basic ConsoleOut Function for ABL Auto Keep default behavior Options available Disable Enable Auto Default setting is Auto ABL PMU message Control Controls the total number of PMU debug message Options available Detailed debug message Coarse debug message Stage completion...

Page 112: ...g the function of AMD PBS Select a submenu item then press Enter to access the related submenu screen Parameter Description AMD PBS RAS Press Enter for advanced configurations SPI Locking Enable or disable SPI Locking for protect ROM part Options Available Enabled Disabled Default option is Disabled ...

Page 113: ...ue is 1000 dec SMI Scale Unit Defines the unit of time scale Options available millisecond second minute Default option is millisecond SMI Period Enter a value Defines the polling interval in milliseconds Default option is 1000 dec Maximum value is 32767 dec 0 disable GHES Notify Type Notification type for deferred corrected errors Options Available Polled SCI Default option is Polled GHES UnCorr ...

Page 114: ...Device UnCorr Err Mask Reg Enter a value Intialize the PCIe AER Uncorrected Error Mask register of PCIe Device PCIe Device UnCorr Error Sev Reg Enter a value Intialize the PCIe AER Uncorrected Error Severity registers of PCIe Device CCIX GHES Deferred Err Notify Type Notification type for CCIX deferred errors Options Available Polled SCI Default option is Polled CCIX GHES Corrected Err Notify Type...

Page 115: ...creen Parameter Description PCIe Link Training Type PCIe Link training in 1 or 2 steps Options available 1 Step 2Step Default setting is 1 Step PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enables or disables program all VR on MB Options available Disabled Enabled Default setting is Enabled North Bridge Press Enter for more information related to CPU 0 and CP...

Page 116: ...s set to Enabled OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configure OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes NOTE This item is configurable when OS Watchdog Timer is set to Enabled OS Wtd Timer Policy Configure OS Watchdog Timer ...

Page 117: ...Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Page 118: ...sing SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options avail...

Page 119: ...nformation The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depending on the product you have purchased ...

Page 120: ...BMC network parameters during BIOS phase Options available Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information Real time synchronize BMC network parameter values Press En...

Page 121: ...C network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IPv6 ...

Page 122: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Page 123: ...es being loaded before Windows loads and gets to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys from the BIOS database Options available Standard Custom Default setting is Custom Restore Factory Keys Forces the system to...

Page 124: ...splays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set Update Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set Update Append Forbidden Signature...

Page 125: ...put the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enable Disable showing the logo during POST Options available Disabled Enabled Default setting is Enabled Boot mode select Selects the boot mode Options available LEGACY UEFI Default setting is UEFI FIXED BOOT ORDER Priorities Boot Option 1 2 3 4 5 Press ...

Page 126: ...es Press Enter to configure the boot priority UEFI USB Drive BBS Priorities Press Enter to configure the boot priority UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Page 127: ...rities The UEFI hard disk drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI hard disk drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 128: ...iorities The UEFI USB drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI USB drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 129: ...orities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 130: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 131: ... so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options available ...

Page 132: ...face 0xE00D ProcMemPhyFenceTraining 0xE00E ProcMemSynchronizeDcts 0xE00F ProcMemSystemMemoryMapping 0xE010 ProcMemMtrrConfiguration 0xE011 ProcMemDramTraining 0xE012 ProcMemBeforeAnyTraining Public interface 0xE013 5 10 3 PMU Test Points ABL Mem PMU Before PMU Firmware load 0xE014 ABL Mem PMU After PMU Firmware load 0xE015 ABL Mem PMU Populate SRAM Timing 0xE016 ABL Mem PMU Populate SRAM Config 0x...

Page 133: ... ABL Mem Read Test pattern 0xE036 ABL Mem Compare Test pattern 0xE037 ABL Mem Online Spare init 0xE038 ABL Mem Chip select Interleave Init 0xE039 ABL Mem Node Interleave Init 0xE03A ABL Mem Channel Interleave Init 0xE03B ABL Mem ECC initialization 0xE03C ABL Mem Platform Specific Init 0xE03D ABL Mem Before callout for AgesaReadSpd 0xE03E ABL Mem After callout for AgesaReadSpd 0xE03F ABL Mem Before...

Page 134: ... init 0xE057 Exit point CPU APOB EDC info init 0xE058 5 10 6 Topology test points ProcTopologyEntry 0xE071 ProcTopologyDone 0xE07C 5 10 7 Extended memory test point ProcMemSendMRS2 0xE080 Sedding MRS3 0xE081 Sending MRS1 0xE082 Sending MRS0 0xE083 Continuous Pattern Read 0xE084 Continuous Pattern Write 0xE085 Mem 2d RdDqs Training begin 0xE086 Mem Before optional callout to platform BIOS to change...

Page 135: ...de 0xE09F TP0xA0 0xE0A0 GNB internal debug code 0xE0A1 GNB internal debug code 0xE0A2 GNB internal debug code 0xE0A3 GNB internal debug code 0xE0A4 GNB internal debug code 0xE0A5 GNB internal debug code 0xE0A6 GNB internal debug code 0xE0A7 GNB internal debug code 0xE0A8 GNB internal debug code 0xE0A9 GNB internal debug code 0xE0AA GNB internal debug code 0xE0AB GNB internal debug code 0xE0AC GNB ...

Page 136: ...Initialization Stage 4 Warning 0xF4C0 ABL 3 GMI xGMI Initialization Stage 4 Error 0xE5C0 ABL 3 GMI xGMI Initialization Stage 5 0xB5C0 ABL 3 GMI xGMI Initialization Stage 5 Warning 0xF5C0 ABL 3 GMI xGMI Initialization Stage 5 Error 0xE6C0 ABL 3 GMI xGMI Initialization Stage 6 0xB6C0 ABL 3 GMI xGMI Initialization Stage 6 Warning 0xF6C0 ABL 3 GMI xGMI Initialization Stage 6 Error 0xE7C0 ABL 3 GMI xGM...

Page 137: ...n AP 0xE0E0 Before IDS calls out to get IDS data 0xE0E1 After IDS calls out to get IDS data 0xE0E2 Before the heap manager calls out to allocate a buffer 0xE0E3 After the heap manager calls out to allocate a buffer 0xE0E4 Before the heap manager calls out to deallocate a buffer 0xE0E5 After the heap manager calls out to deallocate a buffer 0xE0E6 Before the heap manager calls out to locate a buffe...

Page 138: ... Initialization 0xE103 End of phase 1b memory code 0xE104 ABL 1b memory initialization 0xE105 ABL 6 Global memroy error detected 0xE106 ABL 1b Debug Synchronization Function 0xE107 ABL 4b Debug Synchronization Function 0xE108 AblbBegin 0xE109 Ab4bBegin 0xE10A BSP encountered HMAC fail on APOB Header 0xE10B ABL Eroor General ASSERT 0xE2A0 Unknown Error 0xE2A1 ABL Error Log Inig Error 0xE2A2 ABL Err...

Page 139: ...r DDR Recovery error 0xE2BE ABL Error for RRW Test error 0xE2BF ABL Error for On Die Thermal error 0xE2C1 ABL Error for Heap Allocation For Dct Struct Amd Ch Def structure error 0xE2C2 ABL Error for Heap Allocation for PMU SRAM Msg block error 0xE2C3 ABL Error for Heap Phy PLL lock Flure error 0xE2C4 ABL Error for Pmu Training error 0xE2C5 ABL Error for Failure to Load or Verify PMU FW error 0xE2C...

Page 140: ... Error 0xE2EB ABL Error MBIST Heap Allocation Error 0xE2EC ABL Error MBIST Results Error 0xE2EE ABL Error NO Dimm Smcus Info Error 0xE2EE ABL Error Por Max Freq Table Error 0xE2EF ABL Error Unsupproted DIMM Config Error 0xE2F0 ABL Error No Ps Table Error 0xE2F1 ABL Error Cad Bus Timing Not Found Error 0xE2F2 ABL Error Data Bus Timing Not Found Error 0xE2F3 ABL Error LrDIMM IBT Not Found Error 0xE2...

Page 141: ...E30A ABL Error message slave sync function execution Error 0xE30B ABL Error slave offline Error 0xE30C ABL Error Sync Master Error 0xE30D ABL Error Slave Informs Master Info Message Error 0xE30E ABL Error General Assert Error 0xE30F ABL Error No Dimms On Any Channel in sysem 0xE310 ABL Alert PMU Major Message captured 0xE311 ABL Alert PMU REsults Rx Timing captured 0xE312 ABL Alert PMU REsults Tx ...

Page 142: ...A107 TpProcMemSpdTiming 0xA108 TpProcMemDramMapping 0xA109 TpProcMemPlatformSpecificConfig 0xA10A TPProcMemPhyCompensation 0xA10B TpProcMemStartDcts 0xA10C Public interface 0xA10D TpProcMemPhyFenceTraining 0xA10E TpProcMemSynchronizeDcts 0xA10F TpProcMemSystemMemoryMapping 0xA110 TpProcMemMtrrConfiguration 0xA111 TpProcMemDramTraining 0xA112 Public interface 0xA113 TpProcMemWriteLevelizationTraini...

Page 143: ...2 Start sweep 0xA133 Set delay 0xA134 Write test pattern 0xA135 Read Test pattern 0xA136 Compare Test pattern 0xA137 Online Spare init 0xA138 Bank Interleave Init 0xA139 Node Interleave Init 0xA13A Channel Interleave Init 0xA13B ECC initialization 0xA13C Platform Specific Init 0xA13D Before callout for AgesaReadSpd 0xA13E After callout for AgesaReadSpd 0xA13F Before optional callout AgesaHookBefor...

Page 144: ...xA187 Mem After optional callout to platform BIOS to change External Vref during 2d Training 0xA188 Configure DCT For General use begin 0xA189 Configure DCT For training begin 0xA18A Configure DCT For Non Explicit 0xA18B Configure to Sync channels 0xA18C Allocate C6 Storage 0xA18D Before LV DDR4 0xA18E BR CPU BR before AP launch 0xA190 Install AP launched PPI 0xA191 BR after AP launch 0xA192 Befor...

Page 145: ... code calls out to locate a buffer 0xA1F2 After the memory code calls out to locate a buffer 0xA1F3 Before the memory code calls out to locate a buffer 0xA1F4 After the memory code calls out to locate a buffer 0xA1F5 Before the memory code calls out to locate a buffer 0xA1F6 After the memory code calls out to locate a buffer 0xA1F7 5 11 4 PMU Post Code Failed PMU training 0xA1F9 5 11 5 0xA5XX assi...

Page 146: ...eV2 ready to boot exit 0xA52A PspDxeV2 exit boot serivce entry 0xA52B PspDxeV2 exit boot serivce exit 0xA52C PspSmmV2 entry 0xA52D PspSmmV2 exit 0xA52E PspSmmV2 SwSmiCallBack entry build the S3 save area for resume 0xA52F PspSmmV2 SwSmiCallBack exit build the S3 save area for resume 0xA530 PspSmmV2 BspSmmResumeVector entry 0xA531 PspSmmV2 BspSmmResumeVector exit 0xA532 PspSmmV2 ApSmmResumeVector e...

Page 147: ...mand MboxBiosCmdHSTIQuery 0xA5C4 Before send C2P command MboxBiosCmdClrSmmLock 0xA5C7 Before send C2P command MboxBiosCmdPcieInfo 0xA5C8 Before send C2P command MboxBiosCmdGetVersion 0xA5C9 PSP C2P mailbox exit base 0xA5DX Cmd 0xA5D0 Wait C2P command MboxBiosCmdDramInfo finished 0xA5D1 Wait C2P command MboxBiosCmdSmmInfo finished 0xA5D2 Wait C2P command MboxBiosCmdSleep SxInfo finished 0xA5D3 Wait...

Page 148: ...t 0xA90B IOMMU AmdNbioIommu DXE driver entry 0xA90C AmdNbioIommu DXE driver exit 0xA90D ALIB AmdNbioALIB DXE driver entry 0xA90E AmdNbioALIB DXE driver exit 0xA90F SMU AmdSmuV8 PEIM driver entry 0xA910 AmdSmuV8 PEIM driver exit 0xA911 AmdSmuV8 DXE driver entry 0xA912 AmdSmuV8 DXE driver exit 0xA913 AmdSmuV9 PEIM driver entry 0xA914 AmdSmuV9 PEIM driver exit 0xA915 AmdSmuV9 DXE driver entry 0xA916 ...

Page 149: ... NbioBaseHookReadyToBoot Event exit 0xA95D NbioBaseHookPciIO Event entry 0xA95E NbioBaseHookPciIO Event exit 0xA95F 0xA980 0xA99F BR GNB Task GnbEarlyInterfaceCZ entry 0xA970 GnbEarlyInterfaceCZ exit 0xA971 PcieConfigurationInit entry 0xA972 PcieConfigurationInit exit 0xA973 GnbEarlierInterfaceCZ entry 0xA974 GnbEarlierInterfaceCZ exit 0xA975 PcieEarlyInterfaceCZ entry 0xA976 PcieEarlyInterfaceCZ ...

Page 150: ...Late exit 0xA993 GnbSmuServiceRequestV8 entry 0xA994 GnbSmuServiceRequestV8 exit 0xA995 5 11 7 0xACXX assigned for AGESA CCX Module CCX IDS IDS_HOOK_CCX_AFTER_AP_LAUNCH 0xAC10 CCX PEI entry 0xAC50 CCX downcore entry 0xAC51 CCX DXE entry 0xAC55 CCX MP service callback entry 0xAC56 CCX Read To Boot callback entry 0xAC57 CCX SMM entry 0xAC5D CCX PEI start to launch APs for S3 0xAC70 CCX PEI end of la...

Page 151: ...ch finished 0xAF0D FCH InitS3Late dispatch finished 0xAF0E FCH Pei Entry 0xAF10 FCH Pei Exit 0xAF11 FCH MultiFch Pei Entry 0xAF12 FCH MultiFch Pei Exit 0xAF13 FCH Dxe Entry 0xAF14 FCH Dxe Exit 0xAF15 FCH MultiFch Dxe Entry 0xAF16 FCH MultiFch Dxe Exit 0xAF17 FCH Smm Entry 0xAF18 FCH Smm Exit 0xAF19 FCH Smm Dispatcher Entry 0xAF20 FCH Smm Dispatcher Exit 0xAF21 FCH InitReset HwAcpi 0xAF40 FCH InitR...

Page 152: ...0xAF61 FCH InitMid LPC 0xAF62 FCH InitMid SPI 0xAF63 FCH InitMid eSPI 0xAF64 FCH InitMid SD 0xAF65 FCH InitMid eMMC 0xAF66 FCH InitMid SATA 0xAF67 FCH InitMid USB 0xAF68 FCH InitMid xGbE 0xAF69 FCH InitLate HwAcpi 0xAF70 FCH InitLate AB Link 0xAF71 FCH InitLate LPC 0xAF72 FCH InitLate SPI 0xAF73 FCH InitLate eSPI 0xAF74 FCH InitLate SD 0xAF75 FCH InitLate eMMC 0xAF76 FCH InitLate SATA 0xAF77 FCH I...

Page 153: ...PL was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 12 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource ...

Reviews: