- 47 -

BIOS Setup

5-7  Security Menu

The Security menu allows you to safeguard and protect the system from unauthorized use by setting up 
access passwords. 

There are two types of passwords that you can set:

• 

Administrator Password

 

 

Entering this password will allow the user to access and change all settings in the Setup Utility. 

• 

User Password

 

 

Entering this password will restrict a user’s access to the Setup menus. To enable or disable  

 

 

this field, a Administrator Password must first be set. A user can only access and modify the  

 

 

System Time, System Date, and Set User Password fields.

Parameter

Description

Administrator Password

Press [Enter] to configure the administrator password.

User Password

Press [Enter] to configure the user password.

Secure Boot

Press [Enter] to configure advanced items.

Summary of Contents for R152-Z33

Page 1: ...R152 Z33 AMD EPYC 7003 UP Server System 1U 10 Bay Gen4 NVMe User Manual Rev 1 0 ...

Page 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Page 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Page 4: ...e risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is not suitable for use in locations where children are likely to be present WARNING This equipment is intended to be used in Restrict Acce...

Page 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully They...

Page 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Page 7: ...Fan Duct 27 3 3 Installing the CPU and Heat Sink 28 3 4 Installing the Memory 30 3 4 1 Eight Channel Memory Configuration 30 3 4 2 Installing a Memory 31 3 4 3 Processor and Memory Module Matrix Table 31 3 4 4 Memory Population Table 32 3 5 Installing the PCI Expansion Card 33 3 6 Installing the Hard Disk Drive 34 3 7 Installing the Mezzanine Card Optional 35 3 8 Replacing the FAN Assemblly 36 3 9...

Page 8: ...ontroller I350 75 5 2 17 VLAN Configuration 77 5 2 18 MAC IPv4 Network Configuration 78 5 2 19 MAC IPv6 Network Configuration 79 5 3 AMD CBS Menu 80 5 3 1 CPU Common Options 81 5 3 2 DF Common Options 86 5 3 3 UMC Common Options 91 5 3 4 NBIO Common Options 105 5 3 5 FCH Common Options 111 5 3 6 NTB Common Options 115 5 3 7 SOC Miscellaneous Control 116 5 3 8 Workload Tuning 117 5 4 AMD PBS Menu 1...

Page 9: ... 5 8 1 UEFI NETWORK Drive BBS Priorities 135 5 8 2 UEFI Application Boot Priorities 136 5 9 Save Exit Menu 137 5 10 BIOS POST Beep code AMI standard 138 5 10 1 PEI Beep Codes 138 5 10 2 DXE Beep Codes 138 ...

Page 10: ... 10 This page intentionally left blank ...

Page 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Page 12: ...upported Memory speed Up to 3200 2933 MHz Note Follow BIOS setting and memory QVL list if running 3200 Mhz with 2DPC Socket ocket LAN 2 x 1GbE LAN ports 1 x Intel I350 AM2 1 x 10 100 1000 management LAN Socket Socket Video Integrated in Aspeed AST2500 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp Socket Socket Storage 10 x 2 5 Gen4 U 2 hot swappable HDD SSD bays 2 x M 2 slo...

Page 13: ...y jumper 1 x Buzzer Socket Socket Front I O 1 x USB 3 0 1 x Power button with LED 1 x ID button with LED 1 x NMI button 1 x Reset button 2 x LAN activity LEDs 1 x HDD activity LED 1 x System status LED Socket Socket Rear I O 3 x USB 3 0 1 x VGA 1 x COM 2 x RJ45 1 x MLAN 1 x ID button with LED Socket Socket Backplane I O Backplane P N 9CBP10A5NR 00 Speed and bandwidth PCIe Gen4 x4 per port Socket S...

Page 14: ...ABYTE Management Console AMI MegaRAC SP X web interface Dashboard JAVA Based Serial Over LAN HTML5 KVM Sensor Monitor Voltage RPM Temperature CPU Status etc Sensor Reading History Data FRU Information SEL Log in Linear Storage Circular Storage Policy Hardware Inventory Fan Profile System Firewall Power Consumption Power Control LDAP AD RADIUS Support Backup Restore Configuration Remote BIOS BMC CP...

Page 15: ...midity Operating temperature 10 C to 35 C Non operating temperature 40 C to 60 C Operating humidity 8 80 non condensing Non operating humidity 20 95 non condensing NOTE Ambient temperature limited to 30 C if using 280W CPU Socket Socket System Dimension 1U 438mm W x 43 5mm H x 710mm D ...

Page 16: ...l i350 AM2 2 x GbE LAN MGNT BUS TPM USB2 0 x2 USB2 0 x1 USB3 0 x1 USB2 0 x1 USB3 0 x1 USB2 0 x2 USB3 0 x2 USB3 0 x2 Front USB3 0 Rear 3 x USB3 0 USB HUB GL3523 LPC 10 bay 2 5 NVMe 2 x SlimLine 4i 4 x U 2 PCIe x16 Riser CRS101D MLAN VGA COM_1 COM_2 RGMII RTL8211 PHY Security Chip Main SPI Flash 32MB Backup SPI Flash 32MB Main SPI Flash 64MB Backup SPI Flash 64MB Control AMD MILAN Zen3 Core Socket S...

Page 17: ... 2 3 Front Panel LED and Buttons for detail description of function LEDs 2 2 Rear View No Description 1 Serial Port 2 VGA Port 3 Mezzanine Card Slot Option OCP V2 0 Card 4 ID Button 5 10 100 1000 Server management LAN port 6 USB 3 0 Port x 2 7 GbE LAN Port x 2 8 USB 3 0 Port 9 PCIe Card Slot PCIe x16 1 2 HDD 0 HDD 1 HDD 2 HDD 3 HDD 4 HDD 5 HDD 6 HDD 7 HDD 8 HDD 9 2 1 3 5 4 6 7 8 9 PSU1 PSU2 ...

Page 18: ...I S5 state power off System is in ACPI S4 state hibernate mode 4 ID Button This LED represents the RoT function LED behavior Please see the following section for detail LED behavior 5 HDD Status LED Green On HDD locate Blink HDD access Amber On HDD fault Green Amber Blink HDD rebuilding N A Off No HDD access or no HDD fault 6 System Status LED This LED represents the RoT function LED behavior Plea...

Page 19: ...ages OFF OFF Recovering BMC Active Flash Blinks Blue 4 times per second Blinks Green 4 times per second Recovering BIOS Active Flash Blinks Blue 4 times per second Blinks Green 4 times per second Authentication AUTH Pass Recovering BIOS Active Flash OFF OFF BMC AUTH pass after doing recovery BIOS AUTH pass after doing recovery OFF OFF BMC AUTH pass after doing recovery BIOS AUTH pass OFF OFF BMC A...

Page 20: ...or Microchip CEC1702 Once Microchip CEC1702 is working Auth or recovery the front panel LED is controlled by Microchip CEC1702 and vice versa Active Flash Authentication AUTH Fail BMC AUTH Fail Note2 Blinks Blue 1 time per second Blinks Green 1 time per second BIOS AUTH fail Note2 Blinks Blue 1 time per second Blinks Amber 1 time per second BMC AUTH fail after doing recovery Note3 Blinks Blue 2 ti...

Page 21: ... Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring 1 2 1 2 1 2 ...

Page 22: ... Red Blinking AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Red Power supply critical event causing shut down failure OCP OVP fan failure and UVP 0 5 Hz Green Red Alternative Blinking 0 5sec Green and 0 5sec Red Power supply warning events where the power supply continues to operate high temp high power high current and slow fan ...

Page 23: ...Back Panel Removed HDD Slot LED on Back Panel Disk LED Removed HDD Slot RAID SKU No RAID configuration via HBA RAID configuration via HW RAID Card or SW RAID Card HDD Access HDD Present No Access BLINK 2 BLINK 2 OFF OFF OFF OFF OFF OFF Low Speed 2 Hz 3 3 Rebuilding HDD Fault OFF OFF ON OFF ON OFF OFF OFF Locate Amber Green ON 1 ON OFF ON 1 OFF Green Amber Green ON 1 Green OFF Amber Amber OFF LED1 ...

Page 24: ...This page intentionally left blank ...

Page 25: ...u are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do...

Page 26: ...r system cover 1 Loosen and remove the thumbscrew securing the back cover 2 Push down the indentation located at the side of the back chassis 3 Slide the cover horizontally to the back and remove the cover in the direction of the arrow 2 3 1 4 Follow these instructions to remove the front system cover 1 Remove the four screws securing the front system cover to the system 2 Flip open the front syst...

Page 27: ... Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the two fan ducts 2 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 1 2 ...

Page 28: ...w these instructions to install the CPU 1 Align and install the processor on the carrier making sure to line up the triangle markers on the corner of the CPU to the triangle mark on the corner of the CPU carrier 2 Slide the carrier assembly into the channels of the carrier bracket 3 Close the carrier bracket so that it firmly latches on to the CPU socket 4 Close the CPU socket cover 5 Tighten and ...

Page 29: ...tallation CPU 4 5 6 1 3 2 7 2 3 1 4 8 9 3 1 2 4 When installing the heat sink over the CPU use T30 Lobe driver to tighten the 4 captive nuts in sequential order 1g2g3g4 The screw tightening torque 8 0 5kgf cm 17 0 1 0 lbf in ...

Page 30: ..._P0_D1 DIMM_P0_A1 DIMM_P0_A0 DIMM_P0_B0 DIMM_P0_B1 DIMM_P0_C0 DIMM_P0_C1 DIMM_P0_D0 DIMM_P0_D1 DIMM_P0_F0 DIMM_P0_F1 DIMM_P0_G0 DIMM_P0_G1 DIMM_P0_H0 DIMM_P0_H1 DIMM_P0_E0 DIMM_P0_E1 Read the following guidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off ...

Page 31: ...ic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 4 3 Processor and Memory Module Matrix Table Processor and Memory Module Matrix Table 8 DIMMs CPU CPU0 A1 B1 C1 D1 E1 F1 G1 H1 16 DIMMs CPU0 A1 A0 B1 B0 C1 C0 D1 D0 E1 E0 F1 F0 G1 G0 H1 H0 16 DIMMs CPU0 A1 B1 C1 D1 E1 F1 G1 H1 CPU1 I1 J1 K1 L1 M1 N1 O1 P1...

Page 32: ...0 LRDIMM 4DR 4 Ranks 3200 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 EPYC Memory Speed based on DIMM Population One DIMM per Channel EPYC Memory Speed based on DIMM Population Two DIMM per Channel DIMM Type DIMM Population Max EPYC 7003 DDR Frequency MHz DIMM 0 DIMM 1 RDIMM 1R 3200 1R 1R 2933 2R or 2DR 3200 1R 2R or 2DR 2933 2R or 2DR 2R or 2DR 2933 LRDIMM 4DR 3200 4DR 4DR 2933 2S2R 4 Ranks 3200 2S4R 8 R...

Page 33: ...result in personal injury or damage to equipment The PCI riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Remove the thumbscrew on the riser bracket 2 Lift up the riser bracket out of system 3 Remove the slot covers from the riser bracket 4 Orient the PCIe card with the ris...

Page 34: ...ted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install a 2 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever to remove the HDD tray 4 Align the hard disk drive with the positioning screw on the HDD tray 5 Slide hard disk drive into the blank HDD tray 6 Reinsert the HDD tray into t...

Page 35: ... securing the mezzanine card slot cover 2 Remove the slot cover from the system 3 Insert the OCP 2 0 mezzanine card into the compartment ensuring that the card is firmly connected to the connector on the motherboad 4 Secure the OCP 2 0 mezzanine card into the system with three screws 5 Reverse steps 3 4 to replace the OCP 2 0 mezzanine card 4 3 5 6 ...

Page 36: ...ment fan assembly 1 2 Voltages can be present within the server whenever an AC power source is connected This voltage is present even when the main power switch is in the off position Ensure that the system is powered down and all power sources have been disconnected from the server prior to removing installing a system fan Failure to observe these warnings could result in personal injury or damag...

Page 37: ... the left side of the power supply unit along the direction of the arrow 2 Pull the power supply handle at the same time and pull out the power supply unit 3 Insert the replacement power supply unit firmly into the chassis Connect the AC power cord to the replacement power supply 4 Repeat steps 1 3 for replacement of the second power supply 1 3 2 ...

Page 38: ...ow these instructions to install a mezzanine card 1 Insert the mezzanine card into the system ensuring that the connector on the mezzanine card connects to the connector on the motherboard 2 Secure the mezzanine card to the system with three screws NOTE Supports OCP V2 0 Card 2 1 1 ...

Page 39: ... 39 System Hardware Installation HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable Front Panel USB 3 0 Cable Front Switch Cable Front LED Cable 3 11 Cable Routing ...

Page 40: ...m Hardware Installation 40 U 2 NMVe to HDD Back Plane Board Cable NMVe0 U 2 NMVe to HDD Back Plane Board Cable NMVe2 U 2 NMVe to HDD Back Plane Board Cable NMVe1 U 2 NMVe to HDD Back Plane Board Cable NMVe3 ...

Page 41: ...nstallation U 2 NMVe to HDD Back Plane Board Cable NMVe4 U 2 NMVe to HDD Back Plane Board Cable NMVe6 U 2 NMVe to HDD Back Plane Board Cable NMVe5 U 2 NMVe to HDD Back Plane Board Cable NMVe7 A B D C A B D C A B D C A B D C ...

Page 42: ...System Hardware Installation 42 U 2 NMVe to HDD Back Plane Board Cable NMVe6 U 2 NMVe to HDD Back Plane Board Cable NMVe7 ...

Page 43: ...CPU 2 4 3 1 5 6 7 8 9 11 10 12 15 16 16 17 18 19 20 21 22 14 13 Item Description 1 SlimLine SAS Connector U2_0 2 SlimLine SAS Connector U2_1 3 SlimLine SAS Connector U2_2 4 SlimLine SAS Connector U2_3 5 Front panel USB 3 0 Connector 6 Front Panel Connector 7 HDD Back Plane Board Connector ...

Page 44: ...1 TPM Module Connector 12 Serial Port Cable Connector 13 IPMB Connector 14 BMC Firmware Readiness LED 15 Riser Connector 16 OCP Mezzanine Connector 17 System Battery 18 2 x 12 Pin Power Connector 19 2 x 4 Pin 12V Power Connector 20 2 x 4 Pin 12V Power Connector 21 SlimLine SAS Connector SATA0 22 SlimLine SAS Connector SATA1 ...

Page 45: ...ts 4 2 Jumper Settings 21 3 Clear CMOS CLR_CMOS Enable Default 1 2 3 HSMB_SEL PMBUS_SEL ON BIOS recovery mode Normal Default Normal Default BIOS Defined BIOS Defined Clear supervisor password OFF BIOS_PWD BIOS_RCVR J2 1 2 3 4 ...

Page 46: ...Motherboard Components 46 This page intentionally left blank ...

Page 47: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Page 48: ...f the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This...

Page 49: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Page 50: ...e of the installed memory Memory Frequency Note3 Displays the frequency information of the installed memory VR Information Version Displays VR version information AGESA PI Version PI Version Displays AGESA PI version information Onboard LAN Information LAN1 MAC Address Note1 Displays LAN MAC address information LAN2 MAC Address Note2 Displays LAN MAC address information System Date Sets the date f...

Page 51: ... Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default ...

Page 52: ...BIOS Setup 52 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Page 53: ...ble BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Support Select Enable to activate TPM support feature Options available Enabled Disabled Default setting is Disabled ...

Page 54: ...BIOS Setup 54 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Page 55: ...OnBrd Ext VGA Select Note Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard Note This configurable option will be displayed when Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Page 56: ...2 4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 2 Configuration Press Enter for configuration of advanced items ...

Page 57: ... 47 BIOS Setup 5 2 4 1 Serial Port 1 2 Configuration ...

Page 58: ...Devices Settings Note2 Displays the Serial Port 1 2 device settings Change Settings Note2 Select an optimal settings for Super IO Device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ...

Page 59: ...tion Wake System from S5 Note1 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time enabled system will wake on the hr min sec specified Default setting is Disabled Note1 Advanced items prompt when this item is defined ...

Page 60: ...ver LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is ANSI Bits per second Selects the transfer rate for console redirection Optio...

Page 61: ... 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT U...

Page 62: ...MS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when Serial Port for Out of Band Mana...

Page 63: ...ta loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Page 64: ...le the CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is Enabled CPU 0 Information Press Enter to view more information related to CPU ...

Page 65: ... 47 BIOS Setup 5 2 8 PCI Subsystem Settings ...

Page 66: ...ault setting is Auto Onboard LAN Controller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note2 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings Above 4G Decoding Enable Disable memory mapped I O to 4GB...

Page 67: ...ble Auto Enabled Disabled Default setting is Enabled XHCI Hand off Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled USB hardware delays and time outs USB transfer time out The time out val...

Page 68: ...or a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM0 1 00 AMI HDisk0 1 00 Generic Flash Disk 8 07 ADATA USB Flash Drive 1100 Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media wil...

Page 69: ...ions available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Wait time in seconds to press ESC key to abort the PXE boot Press the keys to increase o...

Page 70: ...BIOS Setup 70 5 2 11 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system ...

Page 71: ... 47 BIOS Setup 5 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type ...

Page 72: ...POST LOGO Configuration Parameter Description UEFI Configuration Output Device Type Select output device Options available First loaded Device Onboard Device External Device Specific Device Default setting is Onboard Deviceevice ...

Page 73: ... 47 BIOS Setup 5 2 14 AMD Mem Configuration Status Parameter Description CPU0 Press Enter to view the memory configuration status related to CPU 0 ...

Page 74: ...iguration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration Press Enter for configuration of advanced items ...

Page 75: ...BIOS Setup 75 5 2 16 Intel R Ethernet Controller I350 ...

Page 76: ...ort by blinking the associated LED Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the ...

Page 77: ...g VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Remove VLAN Press Enter to remove an existing VLAN ...

Page 78: ...Note Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter to save all configurations Note This item appears whe...

Page 79: ... for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consective Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address Detection is not performed Policy Options available automatic manual Default setting is automatic Save Changes and Exit Press Enter ...

Page 80: ...etup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Page 81: ...EH cloak individual banks and mask deferred error interrupts from each bank Options available Auto Enabled Disabled Default setting is Auto Core Performance Boost Enable Disable the Core Performance Boost function Options available Auto Disabled Default setting is Auto Global C State Control Controls the IO based C state generation and DF C states Options available Auto Enabled Disabled Default se...

Page 82: ...tions available Auto Enabled Disabled Default setting is Auto SNP Memory RMP Table Coverage Enabled Enter system memory is covered Options available Auto Enabled Disabled Custom Default setting is Auto SMEE Control secure memory encryption enable Options available Auto Enabled Disabled Default setting is Auto Action on BIST Failure Action to take when a CCD BIST failure is detected Options availab...

Page 83: ...ept or decline enabling CCDs processor cores and threads When accepted you can control the number of CCDs to be used the number of cores to be used and whether to enable or disable Simultaneous Multithreading Technology SMT support SMT Control Can be used to disable symmetric multithreading To re enable SMT a POwer CYCLE is needed after select the Enable option Select Auto base on BIOS PCD PcdAmdS...

Page 84: ...ble Disable Default setting is Auto L1 Region Prefetcher Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Options available Auto Enable Disable Default setting is Enable L2 Stream HW Prefetcher Enable Disable L2 Stream HW Prefetcher Options available Auto Enable Disabled Default setting is Enable L2 Up Down...

Page 85: ...BIOS Setup 85 5 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto ...

Page 86: ...Disable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Frezze DF module queues on error Options available Auto Enabled Disabled Default setting is Auto CC6 memory region encryption Controls whether or not the CC6 save restor memory is encrypted Options available Auto Enabled Disabled Default setting is Auto System probe filter Enable...

Page 87: ...efault setting is Auto Poison scrubber control Enable Disable the Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber limit Sets the redirect scrubber limit Options available Auto 2 4 8 Infinite ...

Page 88: ... remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Auto Do not remap Attempt to remap Default setting is Auto DRAM map inversion Enable Disable the DRAM map inversion function Options available Auto Enabled Disabled Default setting is Auto...

Page 89: ...Options available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT remote relative distance Sets the remote socket distance for 2P systems as near 2 8 or far 3 2 Options available Auto Near Far Default setting is Auto ...

Page 90: ...ault setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps 3 link xGMI max speed Specifies the max speed of 3 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps xGMI TXEQ Mode Configures xGMI TXEQ RX vetting Mode Options available Auto TXEQ_Disable...

Page 91: ...Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced items Memory MBIST Press Enter for configuration of advanced items ...

Page 92: ...nel at 3200MHz function select Accept at warning message change Overclock from Auto to Enabled and then set memory speed to 3200MHz DRAM Controller Configuration Press Enter to configure DRAM Controller Configuration CAD Bus Configuration Press Enter to configure CAD Bus Configuration Data Bus Configuration Press Enter to configure Data Bus Configuration Common RAS Press Enter to configure Common ...

Page 93: ...und UrgRefLimit DRAM Maximum Activate Count Options available Auto Unlimited MC 200K 300K 400K 500K 600K 700K Default setting is Auto DRAM Refresh Rate Options available 7 8 usec 3 9 usec Default setting is 7 8 usec Self Refresh Exit Staggering Options available Disabled Trfc 3 Trfc 4 Default setting is Disabled Cmd2T Selects the Cmd2T mode on ADDR CMD Options available Auto 1T 2T Default setting ...

Page 94: ...iguration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto ...

Page 95: ...3 1 3 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Default setting is Auto ...

Page 96: ...tion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurable when DRAM Address Command Parity Retry is set to Enabled Write CRC Enable Enable Disable the Write CRC function Options available Auto Enabled Disabled Default setting is Auto DRAM Write CRC Enable...

Page 97: ...ems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable Options available Auto Enabled Disabled Default setting is Auto DRAM UECC Retry Enable Disable DRAM UECC Retry Options available Auto Enabled Disabled Default setting is Auto ...

Page 98: ...rameter Description Security TSME Enable Disable Transparent SME Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available Auto Enabled Disabled Default setting is Auto ...

Page 99: ...U Training Press Enter to configure PMU Training DFE Traing Enable Disable DDR power down mode Options available Auto Enabled Disabled Default setting is Auto FFE Write Training Auto Enabled Disabled Default setting is Auto PMU Pattern Bits Controls Auto Manual Default setting is Auto ...

Page 100: ... No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address Hash Bank Enable Disable bank address hashing Options available Auto Enabled Disabled Default setting is Auto Address Hash CS Enable Disable CS address hashing Options available Auto Enabled Disabled...

Page 101: ...BIOS Setup 101 5 3 3 3 NVDIMM Parameter Description NVDIMM Disable NVDIMM N feature for memory margin tool Options available No Yes Default setting is No ...

Page 102: ...e Mode Data Eye Mode Default setting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Disable to report 2D data eye results in ABL log for each DQ Chipselect and Channel Options available Auto Enabled Disabled Default setting is Auto Data Eye Press Enter to configure advan...

Page 103: ...ol function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select Lower 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select ECC This item is configurable when Aggressor Static ...

Page 104: ...Voltage Sweep 1D Timing Sweep 2D Full Data Eye Worst Case Margin Only Default setting is Worst Case Margin Only Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available Per Chip Select Per Nibble Default setting is Worst Case Margin Only Read Voltage Sweep Step Size Configures the step size for read Data Eye voltage sweep Options available 1 2 4 Default setting is 2...

Page 105: ...numeration ARI Forwarding Enable for each downstream port Options available Auto Enabled Disabled Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices Auto Disabled Options available Auto Enabled Disabled Default setting is Auto SMU Common Options Press Enter for configuration of advanced items NBIO RAS Common Options Press Enter for configuration...

Page 106: ...available Auto Manual Default setting is Auto Loopback Mode Enabled Disabled PCIe Loopback mode Options available Auto Enabled Disabled Default setting is Auto CV test Set this to Enabled to support running PCIECV tool Auto preserve hardware defaults Options available Auto Enabled Disabled Default setting is Auto CAC Weight Adjustment EDC Mode select Options available Auto Enabled Disabled Default...

Page 107: ...Control Selects use the fused TDP or set customized TDP TDP is used to define the RC thermal model only Options available Auto Manual Default setting is Auto cTDP Display cTDP information EfficiencyModeEn Options available Auto Enabled Default setting is Auto Package Power Limit Control Selects use the fused PPT or set customized PPT PPT will be used as the ASIC power limit Options available Auto ...

Page 108: ...isable Options available Auto Enabled Disabled Default setting is Auto DLMM Support Select DLMM support enable or disable Options available Auto Enabled Disabled Default setting is Auto BoostFmaxEn Options available Auto Enabled Default setting is Auto EDC Current Options available Enable Disable Default setting is Disable LCLK Frequency Control Press Enter for advanced configuration DF PSTATE Mod...

Page 109: ...bit of 0 indicates LOW serverity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFlood Reporting The value may be used to enanle SyncFlood reporting to APML Options available Enabled Disabled Default setting is Disabled Egress Poison Mask High Enables mask for masking of errors log...

Page 110: ...Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable Disable the Log Poison Data from SLINK feature Options available Enabled Disabled Default setting is Disabled PCIe Aer Reporting Mechanism Selects the method of reporting AER errors from PCI Express O...

Page 111: ...arameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items Miscellaneous Options Press Enter for configuration of advanced items ...

Page 112: ...S Setup 5 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is Power off ...

Page 113: ...ALink RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to system controller Options available Auto Enabled Disabled Default setting is Auto ...

Page 114: ... 47 BIOS Setup 5 3 5 3 Miscellaneous Options Parameter Description Miscellaneous Options Boot Time Enable Options available Auto Enabled Disabled Default setting is Auto ...

Page 115: ...NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P1 NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P2 NTB Enable Options available Auto Enable Default setting is Auto Socket 0 P3 NTB Enable Options available Auto Enable Default setting is Auto ...

Page 116: ...nable Disable the ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number of PMU debug messages Options available Auto Enabled Disabled Default setting is Auto Note This item appears when ABL Console Out Control is set to Enabled ...

Page 117: ...ter Description Workload Tuning Workload Profile Select the profile for different workloads Default setting is Auto Performance Tracing Enable to allow capturing performance traces Options available Auto Enabled Disabled Default setting is Auto ...

Page 118: ...king for protect ROM part Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn Reserved 1M bytes MMIO space on 1M boundary when iLA TraceMemoryEn disabled Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn reserved MMIO Reserved function SRIS mode debug Control SRIS mode debug Options available Auto Enabled Disabled Default setting is Auto ...

Page 119: ...Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for uncorrected errors Options available Polled NMI Default setting is NMI PCIe GHES Notify Type Selects the Notification type for PCIe corrected errors Options available Polled SCI Default setting is Polled...

Page 120: ...RR Notify Type Selects the Notification type for CCIX deffered error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX corrected error Options available Polled SCI Default setting is Polled DDR4 DRAM Hard Post Package Repair This feature allows spare DRAM rows to replace malfunctioning rows via an in field repair mecha...

Page 121: ...er to access the related submenu screen Parameter Description PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available Enabled Disabled Default setting is Enabled North Bridge Press Enter for configuration of advanced items Fabric Resource Press Enter for configuration of advanced items ...

Page 122: ...er Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU0 Information Press Enter to view information related to CPU 0 CPU1 Information Press Enter to view information related to CPU 1 ...

Page 123: ...BIOS Setup 123 5 5 2 Fabric Resource Parameter Description Fabric Resource Socket 0 1 NBIO_ PCIe Bus Number Change Socket 0 1 NBIO_ PCIe Bus Number ...

Page 124: ... Default setting is Do Nothing OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configures OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes Please note that this item is configurable when OS Watchdog Timer is set to Enabled OS Wtd Timer Policy C...

Page 125: ...ed 2 minutes 4 minutes 6 minutes Default setting is 2 minutes System Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Page 126: ...e SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options availabl...

Page 127: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Page 128: ...g is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information VLAN Support Set to BMC enabled diisabled VLAN Options available Enabled Disable...

Page 129: ...work during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Enable Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IP...

Page 130: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Page 131: ...ooting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys from the BIOS database Options avail...

Page 132: ... Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set New Append ...

Page 133: ...ber of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Boot mode select Selects the boot ...

Page 134: ...ure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Page 135: ...rities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 136: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Page 137: ...ne so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options availabl...

Page 138: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource r...

Page 139: ...BIOS Setup 139 This page intentionally left blank ...