BIOS Setup
- 66 -
Parameter
Description
Serial Port for Out-of-Band
EMS Console Redirection
Settings(continued)
Flow Control
–
Flow control can prevent data loss from buffer overflow. When
sending data, if the receiving buffers are full, a 'stop' signal can
be sent to stop the data flow. Once the buffers are empty, a 'start'
signal can be sent to re-start the flow. Hardware flow control uses
two wires to send start/stop signals.
– Options available: None, Hardware RTS/CTS, Software Xon/Xoff.
Default setting is
None
.