BIOS Setup
- 124 -
5-3-4-2 NBIO RAS Common Options
Parameter
Description
NBIO RAS Common Options
NBIO RAS Control
Options available: Disabled, MCA, Legacy. Default setting is
MCA
.
Egress Poison Serverity High
Configures the Egress Poison High Serverity. Each bit set to 1 enables
High serverity on the associated IOHC egress port. A bit of 0 indicates
LOW serverity.
Egress Poison Serverity Low
Configures the Egress Poison Low Serverity. Each bit set to 1 enables
High serverity on the associated IOHC egress port. A bit of 0 indicates
LOW serverity.
NBIO SyncFlood Generation
The value may be used to mask SyncFlood caused by NBIO RAS options.
Options available: Auto, Enabled, Disabled. Default setting is
Auto
.
NBIO SyncFlood Reporting
The value may be used to enanle SyncFlood reporting to APML.
Options available: Enabled/Disabled. Default setting is
Disabled
.
Egress Poison Mask High
Enables mask for masking of errors logged in EGRESS_POISON_
STATUS. For each bit set to 1, errors are masked. For each bit set to 0,
errors trigger response actions.
Egress Poison Mask Low
Enables mask for masking of errors logged in EGRESS_POISON_
STATUS. For each bit set to 1, errors are masked. For each bit set to 0,
errors trigger response actions.
Summary of Contents for R182-Z93
Page 1: ...R182 Z93 AMD EPYC 7003 DP Server System 1U 10 Bay Gen4 NVMe User Manual Rev 1 0 ...
Page 10: ... 10 This page left intentionally blankThis ...
Page 16: ... 16 Hardware Installation 1 3 System Block Diagram ...
Page 42: ...System Hardware Installation 42 NVMe Card 4 5 NVMe Card 6 7 Top Bo om Bo om Top R182 Z92 ...
Page 43: ... 43 System Hardware Installation NVMe Card 8 9 HDD Backplane Board Signal R182 Z92 ...
Page 44: ...System Hardware Installation 44 HDD Backplane Board Power Front Panel IO R182 Z92 ...
Page 45: ... 45 System Hardware Installation Front Panel USB ...
Page 46: ...System Hardware Installation 46 This page intentionally left blank ...
Page 50: ...Motherboard Components 50 This page left intentionally blankThis ...
Page 56: ...BIOS Setup 66 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...
Page 61: ... 71 BIOS Setup 5 2 4 1 Serial Port 1 2 Configuration ...
Page 69: ... 79 BIOS Setup 5 2 8 PCI Subsystem Settings ...
Page 80: ...BIOS Setup 90 5 2 17 Intel R I350 Gigabit Network Connection ...
Page 144: ...BIOS Setup 154 This page intentionally left blank ...