- 125 -
BIOS Setup
Parameter
Description
Uncorrected Converted to
Poison Enabke Mask High
Enables mask for masking of uncorrectable parity errors on internal
arrays.
Uncorrected Converted to
Poison Enabke Mask Low
Enables mask for masking of uncorrectable parity errors on internal
arrays.
System Hub Watchdog Timer
Specifies the timer interval of the SYSHUB Watchdog timer in miliseconds.
SLINK Read Response OK
This item specifies whether SLINK read response errors are converted to
an Okay response.
Options available: Enabled/Disabled. Default setting is
Disabled
.
SLINK Read Response Error
Handling
Options available: Enabled, Trigger MCOMMIT Error, Log Errors in MCA.
Default setting is
Log Errors in MCA
.
Log Poison Data from SLINK
Enable/Disable the Log Poison Data from SLINK feature.
Options available: Enabled/Disabled. Default setting is
Disabled
.
PCIe Aer Reporting
Mechanism
Selects the method of reporting AER errors from PCI Express.
Options available: Auto, Firmware First, OS First, MCA.
Default setting is
Auto
.
Edpc Control
Options available: Auto, Enabled, Disabled. Default setting is
Disabled
.
NBIO Poison Consumption
Options available: Auto, Enabled, Disabled. Default setting is
Auto
.
Sync Flood on PCIe Fatal
Error
Options available: Auto, True, False. Default setting is
Auto
.
Summary of Contents for R182-Z93
Page 1: ...R182 Z93 AMD EPYC 7003 DP Server System 1U 10 Bay Gen4 NVMe User Manual Rev 1 0 ...
Page 10: ... 10 This page left intentionally blankThis ...
Page 16: ... 16 Hardware Installation 1 3 System Block Diagram ...
Page 42: ...System Hardware Installation 42 NVMe Card 4 5 NVMe Card 6 7 Top Bo om Bo om Top R182 Z92 ...
Page 43: ... 43 System Hardware Installation NVMe Card 8 9 HDD Backplane Board Signal R182 Z92 ...
Page 44: ...System Hardware Installation 44 HDD Backplane Board Power Front Panel IO R182 Z92 ...
Page 45: ... 45 System Hardware Installation Front Panel USB ...
Page 46: ...System Hardware Installation 46 This page intentionally left blank ...
Page 50: ...Motherboard Components 50 This page left intentionally blankThis ...
Page 56: ...BIOS Setup 66 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...
Page 61: ... 71 BIOS Setup 5 2 4 1 Serial Port 1 2 Configuration ...
Page 69: ... 79 BIOS Setup 5 2 8 PCI Subsystem Settings ...
Page 80: ...BIOS Setup 90 5 2 17 Intel R I350 Gigabit Network Connection ...