- 26 -
System Appearance
2-6 Power Supply Unit LED
PSU LED
State
Description
OFF
No AC power to all power supplies
1Hz Green Blinking
AC present / only standby on / Cold redundant mode
2Hz Green Blinking
Power supply firmware updating mode
Amber
AC cord unplugged or AC power lost; with a second
power supply in parallel still with AC input power
Power supply critical event causing shut down:
failure, OCP, OVP, fan failure and UVP
1Hz Amber Blinking
Power supply warning events where the
power supply continues to operate:
high temp, high power, high current and slow fan
Summary of Contents for R283-S91-AAE1
Page 10: ... 10 This page intentionally left blank ...
Page 40: ... 40 System Hardware Installation 2 2 1 1 3 2 4 5 3 2 4 5 ...
Page 72: ... 72 BIOS Setup 5 2 4 PCI Subsystem Settings ...
Page 81: ... 81 BIOS Setup 5 2 12 Intel R i350 Gigabit Network Connection ...
Page 86: ... 86 BIOS Setup 5 3 1 Processor Configuration ...