Follow the below steps to install the Intrusion Switch:
1. Align the intrusion switch with the intrusion switch slot.
2. Slide the intrusion switch until it is firmly seated in the intrusion switch slot.
3. Connect the intrusion switch cable to the connector on the system board.
After installing the Intrusion Switch ensure the following:
1. Install internal PERC riser.
2. Follow the procedure listed in
After working inside your system
.
Drives
This describes the procedure to install and remove the Drives.
Removing a Drive Blank
l
Follow the safety guidelines listed in
l
If installed, remove the front bezel.
CAUTION: To maintain proper system cooling, drive blanks must be installed in all
empty drive slots.
CAUTION: Mixing drive blanks from previous generations of PowerEdge servers is not
supported.
Follow the below steps to remove the Drive Blank:
1. Press the release button, and slide the drive blank out of the drive slot.