Te
mplat
e
M
odu
le
, V
e
rs
io
n 1.
2,
11
.0
9.
201
8,
Diagnostics and troubleshooting
Gigaset N670 IP PRO / ALL UK en / A31008-XXXXX-XXXX-X-XX / dignostics.fm / 4/18/19
60
Actions
Exporting the information into a CSV file
For further processing of the statistic data you can export the data into a file with CSV (Comma
separated Value) format.
¤
Click on
Export
Select the location where the file should be stored using the system file
selection dialogue.
Resetting the statistics
¤
Click on
Reset all
. . . the counters in the table are reset to 0.
Filtering the list
¤
From the
Choose column
option menu select the column for which you want to set a filter.
Note that columns may be hidden.
¤
In the text field enter the filter criteria
Click on
Filter
. . . only the entries matching the filter
are shown.
For filtering the list according to specific counter values the following operators are possible:
For the
MAC address
column only the following condition is allowed: = MAC address
The MAC address must be in the following format:
aabbccddeeff
(without colons)
Deleting the filter:
Click on
Clear
Examples:
Only base stations with more than 20 busy situations should be displayed in the table. This could
be achieved by the following filter settings.
Only base stations with less than 5 call interruptions should be displayed in the table. This could
be achieved by the following filter settings.
Displaying/ hiding columns
¤
Click on the
View
option menu on the right
Select the columns you want to be displayed
in the table (
/
= displayed/hidden).
Names of columns which cannot be hidden are greyed out.
<
less than
>
more than
=
equal to
<= less or equal
>= more or equal
Busy
Filter
Clear
>20
Call drops
Filter
Clear