39
Appendix
Gigaset S455 / USA EN / A31008-M1714-R301-3-6019 / appendix.fm / 21.8.07
Specifications
Recommended batteries
(Valid at the time of going to press)
Nickel-metal-hydride (NiMH):
u
Sanyo Twicell 650
u
Sanyo Twicell 700
u
Panasonic 700mAh "for DECT"
u
GP 700mAh
u
Yuasa Technology AAA Phone 700
u
Varta Phone Power AAA 700mAh
u
GP 850 mAh
The handset is supplied with the author-
ized batteries.
Handset operating times/charging
times
The operating and charging times apply
only when using the recommended bat-
teries.
Base station power consumption
In standby mode: approx. 2 watts
During a call: approx. 3 watts.
The other party cannot hear you.
You have pressed the
u
(INT) key. The hand-
set is placed on hold.
¥
Switch on the microphone again (page 11).
The incoming call number is not displayed
although CIP is set
.
Caller ID is not enabled.
¥
Caller
should ask network provider to acti-
vate Caller ID (CI).
You hear an error tone when keying an input
(a descending sequence of tones).
Action has failed/invalid input.
¥
Repeat the operation.
Watch the display and refer to the operating
instructions if necessary.
You cannot listen to messages on the net-
work mailbox
.
Your phone system is set for pulse dialing.
¥
Set your phone system to tone dialing.
The calls list does not indicate a time for a
message.
Date/time are not set.
¥
Set the date/time (page 9).
The answer machine reports "PIN is incor-
rect" during remote operation.
1. System PIN entered is incorrect
¥
Repeat input of system PIN,
2. System PIN is still set to 0000.
¥
Change system PIN to a number other
than 0000 (page 34).
The answer machine does not record any
messages/has switched over to 'announce
only'.
Its memory is full.
¥
Delete old messages.
¥
Play back new messages and delete.
Capacity 650
mAh
Standby time
Approx. 170 hours (7 days)
Calling time
Approx. 13 hours
Charging time
approx. 6 hours
Note:
When the lighting is switched on, the standby
time of the handset is reduced to approx. 30
hours.