background image

 

Capricorn Outdoor CPE Installation Guide 

 

DCP0000212(B)                                               Proprietary to Gilat Satellites Networks Ltd.  

 

Capricorn MEC Outdoor CPE General Information 

This installation guide is applicable to SkyEdge II-c CAPRICORN OUTDOOR 

DC/MEC/48vODU (P/N 596100). 

The measurements of this SkyEdge II-c Capricorn Outdoor CPE model are  

300x211x105 mm. Make sure to leave 30 cm for front panel connections. 

 

To install the SkyEdge II-c Capricorn Outdoor CPE, the installer must: 

 

Be trained in the installation of the SkyEdge II-c Capricorn MEC Outdoor CPE. 

 

Have the CPE configuration parameters available.

 

 

VSAT AC and DC power supplies are provided by Gilat. If the power to the VSAT 

is not through an AC or DC adaptor (e.g., batteries, solar panels, rectifier ETC), the 

power solution must be approved by the Gilat Technical Support. 

Unpacking Guidelines 

1.

 

Unpack the Capricorn MEC Outdoor CPE unit and its accessories: 

 

SE II-c Capricorn MEC Outdoor DC-48 to 48V ODU  

 

Two RF cables - CB018520 

 

Five cable glands - CN101943 

 

RF Lightning Protection - LNC00214 

2.

 

Compare the contents with the supplied BOM and verify that nothing is missing. 

3.

 

Verify that nothing is damaged. 

The Capricorn MEC Outdoor CPE contains 5 LAN ports, a USB port and can use the DC 

input 48V only {Pin 1+, Pin 2-(RTN), Pin 3} (Figure 1).  

 

 

Figure 1: Capricorn MEC Outdoor – Front Panel 

The Capricorn MEC Outdoor contains 6 LEDs: 

 

Power  

 

Satellite Network 

 

Link Status 

 

TX 

 

RX 

 

MEC power  

 

 

Warning

 

B

EFORE INSTALLING THE UNIT

,

 VERIFY THAT THE ANTENNA AND 

DC

 POWER CORD 

ARE GROUNDED SO AS TO PROVIDE PROTECTION AGAINST VOLTAGE SURGES AND 
STATIC CHARGES

S

ECTION 

810

 OF THE 

US

 

N

ATIONAL 

E

LECTRICAL 

C

ODE

,

 

ANSI/NFPA

 

70,

 AND 

S

ECTION 

54

 OF THE 

C

ANADIAN 

E

LECTRICAL 

C

ODE PROVIDE INFORMATION WITH 

REGARD TO PROPER GROUNDING OF THE MAST AND SUPPORTING STRUCTURE

,

 

GROUNDING OF THE LEAD

-

IN WIRE TO AN ANTENNA DISCHARGE UNIT

,

 SIZE OF 

GROUNDING CONDUCTORS

,

 LOCATION OF ANTENNA DISCHARGE UNIT

,

 CONNECTION 

TO GROUNDING ELECTRODES AND REQUIREMENTS FOR THE GROUNDING 
ELECTRODE

.

 

 

Reviews: