MDE-5386D Hybrid Card Reader S (HCRS) Kit (M13940KXXX) Installation Instructions (Canada) · June 2020
Page 39
Appendix A: Configuring/Activating FlexPay EMV CRIND Keypad
6
Option
Description
1
UNIT ACTIVATION (to activate the unit)
3
READER WARNING: enabled
OK
SAVE CHANGES AND EXIT
CANCEL
UNDO ALL CHANGES AND EXIT
Enter the matching password into the Security Setup Menu and press
OK
. After you enter the
password correctly, the system will show the sensors status and four options.
Figure 36: Security Setup Menu - Options Screen
7
Press
1
to activate the unit. The message, “ALL DISMOUNTING SENSORS ENABLED
UNIT ACTIVATED” is displayed. Press
OK
to exit the menu and press
CANCEL
to restart
the FlexPay EMV CRIND.
Figure 37: Activation Screen
Activation enables all the connected secure modules.
Note: It is not possible to enable only one component and retain the other components in an
inactive state.
Contrary to activation, the deactivation procedure does not require keypad entries. Therefore,
no options are available in the menu. When the system sensors detect that a module with
mounting sensors is dismounted, it automatically self-deactivates. The activation procedure
must be repeated.
At each power up, if the FlexPay EMV CRIND main processor detects a module that is not
activated, it will automatically enter the Service Menu (green screen).