NC3L Verifone 12" - Installation and maintenance
21
7 . 2 .
E L E C T R I C A L I N S T A L L A T I O N
In the following diagram you can see the cables connections that needs to be done to install the NC3L.
10. The Ethernet connection cable shall be a CAT 5 S/UTP (FTP) shielded cable, flameproof and resistant
to hydrocarbon and/or industrial oils.
Connect the Ethernet cable(s) from the display card(s) connector (below the battery), inside the crind
head, to the main Ethernet connection(s) coming from the kiosk.
Cable type: cable suitable for buried installation with oil resistant oversheath, minimum 8x0,5
mm²,maximum 8x2 mm².