NC3L Verifone 12" - Installation and maintenance
26
8.
NC3L POWER-ON PROCEDURE FOR
TEMPERATURES LOWER THAN 0 °C
WARNING:
this procedure is recommended to guarantee the correct functioning of the terminal in term of
performances and reliability.
Not following this procedure could cause a temporary lack of functionalities or deterioration of performance
(slow printing ticket, slow refresh of terminal display or loss of colour brightness, lower rate of successful
magnetic card reading)
1. Before starting the procedures, make sure that the
AC power switch
in the kiosk is switched
OFF
.
2. Energize the
Heaters
supply line from the kiosk.
3. Make sure that the heating system (h fan) is correctly working.
4. Close the NC3L doors.
5.
WAIT 2 HOURS
until manual heating procedure will be completed.
6. Now turn
ON
the switch of the
AC power switch
in the kiosk to power on the electronics devices.